| Sl. No. | Item Description |
| 1 | H.S.R. Item |
| 2 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (25 Sqmm size) |
| 3 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (50 Sqmm size) |
| 4 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (70 Sqmm size) |
| 5 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (120 Sqmm size) |
| 6 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (150 Sqmm size) |
| 7 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (185 Sqmm size) |
| 8 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (240 Sqmm size) |
| 9 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (95 Sqmm size) |
| 10 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 15 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Housing Board B/Stn.) |
| 11 | `RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 15900 LPM x 12.50 M (At 2nd W/W for WTP-1 for R/W) |
| 12 | `RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 8400 LPM x 12.50 M (At 2nd W/W for WTP-2 for R/W) |
| 13 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 75 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 2nd W/W for WTP-1 for R/W) |
| 14 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 40 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 2nd W/W for WTP-2 for R/W) |
| 15 | Providing and fixing of 15 mm nominal diameter water meter as per IS 779:1994 Inferential type dry dial, mechanical driven, non megnatic drive, straight reading cyclometer type, 7-inline consequent digits with one centre point for easy reading complete in all respect. |
| 16 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 3rd W/W for R/W) |
| 17 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) cast Iron, class B (IS 1536) complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion etc up to the site of work.450 mm nominal diameter |
| 18 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 450 mm nominal diameter |
| 19 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) cast Iron, class B (IS 1536) complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion etc up to the site of work.350 mm nominal diameter |
| 20 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 150 mm nominal diameter |
| 21 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 200 mm nominal diameter |
| 22 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 250 mm nominal diameter |
| 23 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 300 mm nominal diameter |
| 24 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 350 mm nominal diameter |
| 25 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 400 mm nominal diameter |
| 26 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) cast Iron, class B (IS 1536) complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion etc up to the site of work.400 mm nominal diameter |
| 27 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Hanuman Dhani B/Stn.) |
| 28 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 3400 LPM x 40.00 M Head (For Hanuman Dhani B/Stn.) |
| 29 | Less credit for old Good bricks 13.80 x 60% = 8 @ 480 brick per cum = 3974 |
| 30 | Less credit for old bricks bats @ 40% ( Cum )Total 13.80 x 40% = 5.52 |
| 31 | Less credit for old Good bricks 17.57 x 60% = 10.54 @ 480 brick per cum = 5060 |
| 32 | Less credit for old bricks bats @ 40% ( Cum )Total 17.57 x 40% = 7.03 |
| 33 | Less credit for old Good bricks 9.94 x 60% = 5.96 @ 480 brick per cum = 2862 |
| 34 | Less credit for old bricks bats @ 40% ( Cum )Total 9.94 x 40% = 3.97 |
| 35 | Less credit for old Good bricks 13.80 x 60% =8.28 @ 480 brick per cum = 3974 |
| 36 | Less credit for old Good bricks 23.18 x 60% =13.91 @ 480 brick per cum = 6677 |
| 37 | Less credit for old Good bricks 19.62 x 60% = 11.77 @ 480 brick per cum = 5651 |
| 38 | Less credit for old Good bricks 71.73 x 60% =43.04 @ 480 brick per cum = 20658 |
| 39 | Less credit for old bricks bats @ 40% ( Cum )Total 23.18 x 40% = 9.27 |
| 40 | Less credit for old bricks bats @ 40% ( Cum )Total 19.62 x 40% = 7.85 |
| 41 | Less credit for old bricks bats @ 40% ( Cum )Total 71.73 x 40% =28.69 |
| 42 | Less credit for old Good bricks 10.35 x 60% =6.21 @ 480 brick per cum = 2981 |
| 43 | Less credit for old bricks bats @ 40% ( Cum )Total 10.35 x 40% = 4.14 |
| 44 | Less credit for old Good bricks 14.87 x 60% =8.92 @ 480 brick per cum = 4283 |
| 45 | Less credit for old bricks bats @ 40% ( Cum )Total 14.84 x 40% =5.95 |
| 46 | Less credit for old Good bricks 16.56 x 60% =9.94 @ 480 brick per cum = 4769 |
| 47 | Less credit for old Good bricks 40.84 x 60% =24.50 @ 480 brick per cum = 11762 |
| 48 | Less credit for old bricks bats @ 40% ( Cum )Total 16.56 x 40% =6.62 |
| 49 | Less credit for old bricks bats @ 40% ( Cum )Total 40.84 x 40% =16.34 |
| 50 | Less credit for steel bars from RCC cover slab @ 70 kg ( Cum ) |
| 51 | SERVER GRADE HARDWAREs IPC 1 No. Desktop Intel core i9 processor 16 GB RAM 512GB SSD(HP/Dell) 2 x Ethernet Port ,Windows 10 Professional or latest operating systems with MS office 1 No. 36” INCH SCREEN DISPLAY (LG/SAMSUNG) 1 No. SCADA LICENSE KEY 2500 TAGS1 No.UPS 600 VA (Microtek/Luminous/Su-kam) 1 No. PRINTER COLOR A3 Inkjet (HP/EPSON) ` |
| 52 | `PLC HMI SYTEM , ENCLOSURE and ACCESORIES:- AUTOMATION OF Clear Water Pump House -PLC and HMI SYSTEM consisting of 1 No. PLC, 1 No. HMI 7 inch, 1 No. IOT MODULE-CLOUD GATEWAY -1 No. POWDER COATED CNC FABRICATED ENCLOSURE- ENCLOSURE- ACCESSORIES- 100 Nos. TERMINAL BLOCK , 1No. SMPS , 1 No. FAN and FILTTERS , 200 m CONTROL WIRING , 4 No. Relay Cards, 1 No.ISOLATION TRANSFORMER 500 VA , 3 Nos. PUSH BUTTON and INDICATORS , 1 No. LED LIGHT , 1 No. PVC CHANNELS, 1 No. SURGE PROTECTION DEVICE, 1 No.DIN RAILS, and MISC ACCESSORIES NUT, BOLTS, HINGES AND OTHER MECHINCAL ACCESSORIES and MANUFACTURING complete- At Automation of Clear Water Pump House.` |
| 53 | Pressure transmitter. |
| 54 | `Residual chlorine analyzer with 4-20mA output and RS-485 communication.` |
| 55 | `Ultrasonic Level transmitter at Clear water tank ( Clear Water Tank 1 Nos).` |
| 56 | `Ultrasonic Flow meter for open channel, 4-20mA output and RS-485 communication for WTP` |
| 57 | `pH meter, Turibity analyzer with 4-20mA output and RS-485 communication at WTP` |
| 58 | Electromagnetic Flow meter of Max 500 mm Dia, 4-20mA output and RS-485 communication at outlet from clear water pump House. |
| 59 | Electromagnetic Flow meter of 500 mm Dia, 4-20mA output and RS-485 communication at outlet from Direct Distribution. |
| 60 | Electrically operated actuated sluice valve of max 500 mm dia. |
| 61 | `PLC HMI SYTEM , ENCLOSURE and ACCESORIES: -PLC and HMI SYSTEM consisting of 1 No. PLC, 1 No. HMI 7 inch, 1 No. IOT MODULE-CLOUD GATEWAY -1 No. POWDER COATED CNC FABRICATED ENCLOSURE- ENCLOSURE- ACCESSORIES- 250 Nos. TERMINAL BLOCK , 1No. SMPS , 1 No. FAN and FILTTERS , 400 m CONTROL WIRING , 10 No. Relay Cards, 1 No. ISOLATION TRANSFORMER 500 VA , 3 Nos. PUSH BUTTON and INDICATORS , 1 No. LED LIGHT , 1 No. PVC CHANNELS, 1 No. SURGE PROTECTION DEVICE, 1 No.DIN RAILS, and MISC ACCESSORIES NUT, BOLTS, HINGES AND OTHER MECHINCAL ACCESSORIES and MANUFACTURING complete including transportation and other charges- At Automation for Water Treatment Plant (10.00 MLD)` |
| 62 | Level Switches at different tanks (Alum Dosing Tank- 2 Nos, Sludge Sump 1 Nos., Service Tank 1 Nos., CWT -1 Nos., Filter-4 Nos., Sedimentation Tank- 6 Nos.) at WTP 10.00 MLD |
| 63 | `Electrically operated actuated valve of max 500mm dia (Floculator Chamber- 1 Nos, Mixing Chamber- 1 No., Influent to Filter bed-4 No., Effluent clear Water -2 Nos, Effluent Back Washed Water - 1Nos.,Service tank For Back Wash - 1Nos., Air Blower - 2 Nos.) at WTP 10.00 MLD` |
| 64 | Loss of head Transmitter with 4-20mA output (4 Nos. Filter bed each WTP) at WTP 10.00 MLD |
| 65 | `PLC HMI SYTEM , ENCLOSURE and ACCESORIES: -PLC and HMI SYSTEM consisting of 1 No. PLC, 1 No. HMI 7 inch, 1 No. IOT MODULE-CLOUD GATEWAY -1 No. POWDER COATED CNC FABRICATED ENCLOSURE- ENCLOSURE- ACCESSORIES- 250 Nos. TERMINAL BLOCK , 1No. SMPS , 1 No. FAN and FILTTERS , 400 m CONTROL WIRING , 10 No. Relay Cards, 1 No. ISOLATION TRANSFORMER 500 VA , 3 Nos. PUSH BUTTON and INDICATORS , 1 No. LED LIGHT , 1 No. PVC CHANNELS, 1 No. SURGE PROTECTION DEVICE, 1 No.DIN RAILS, and MISC ACCESSORIES NUT, BOLTS, HINGES AND OTHER MECHINCAL ACCESSORIES and MANUFACTURING complete including transportation and other charges- At Automation for Water Treatment Plant 2 unit (10.00 plus 10.00 MLD)` |
| 66 | Level Switches at different tanks (Alum Dosing Tank- 2 Nos, Sludge Sump 1 Nos., Service Tank 1 Nos., CWT -1 Nos., Filter-4 Nos., Sedimentation Tank- 3 Nos.) at WTP 2 unit (10.00 plus 10.00 MLD) |
| 67 | `Electrically operated actuated valve of max 500mm dia (Floculator Chamber- 1 Nos, Mixing Chamber- 1 No., Influent to Filter bed-4 No., Effluent clear Water -2 Nos, Effluent Back Washed Water - 1Nos.,Service tank For Back Wash - 1Nos., Air Blower - 2 Nos.) at WTP 2 unit (10.00 plus 10.00 MLD)` |
| 68 | Loss of head Transmitter with 4-20mA output (4 Nos. Filter bed each WTP) at WTP 2 unit (10.00 plus 10.00 MLD) |
| 69 | Electromagnetic Flow meter of Max 750 mm Dia, 4-20mA output and RS-485 communication at outlet from clear water pump House. |
| 70 | Electromagnetic Flow meter of 750 mm Dia, 4-20mA output and RS-485 communication at outlet from Direct Distribution. |
| 71 | Electrically operated actuated sluice valve of max 750 mm dia. |
| 72 | Level Switches at different tanks (Alum Dosing Tank- 2 Nos, Sludge Sump 1 Nos., Service Tank 1 Nos., CWT -1 Nos., Filter-4 Nos.) at WTP 19.00 MLD |
| 73 | `Electrically operated actuated valve of max 750mm dia (Floculator Chamber- 1 Nos, Mixing Chamber- 1 No., Influent to Filter bed-4 No., Effluent clear Water -2 Nos, Effluent Back Washed Water - 1Nos.,Service tank For Back Wash - 1Nos., Air Blower - 2 Nos.) at WTP 19.00 MLD` |
| 74 | Loss of head Transmitter with 4-20mA output (4 Nos. Filter bed each WTP) at WTP 19.00 MLD |
| 75 | `PLC HMI SYTEM , ENCLOSURE and ACCESORIES: -PLC and HMI SYSTEM consisting of 1 No. PLC, 1 No. HMI 7 inch, 1 No. IOT MODULE-CLOUD GATEWAY -1 No. POWDER COATED CNC FABRICATED ENCLOSURE- ENCLOSURE- ACCESSORIES- 250 Nos. TERMINAL BLOCK , 1No. SMPS , 1 No. FAN and FILTTERS , 400 m CONTROL WIRING , 10 No. Relay Cards, 1 No. ISOLATION TRANSFORMER 500 VA , 3 Nos. PUSH BUTTON and INDICATORS , 1 No. LED LIGHT , 1 No. PVC CHANNELS, 1 No. SURGE PROTECTION DEVICE, 1 No.DIN RAILS, and MISC ACCESSORIES NUT, BOLTS, HINGES AND OTHER MECHINCAL ACCESSORIES and MANUFACTURING complete including transportation and other charges- At Automation for Water Treatment Plant (19.00 MLD)` |
| 76 | Credit of existing outlived pump sets. (At 2nd W/W, MBS and its B/Stn.)At 2nd water works for WTP-1 (R/W pump) - 2 no. (75 HP) At 2nd water works for WTP-2 (R/W pump) - 2 no. (150 HP) At 2nd water works (C/W pump) - 2 no. (20 HP)At MBS Dadri road (C/W pump) - 3 no. (200 HP)B/Stn. - 11 (Lajpat Nagar) - 2 no. (45 HP) B/Stn. - 12 (TIT B/stn.) - 2 no. (40 HP) B/Stn. - 13 (Durga colony) - 2 no. (50 HP) B/Stn. - 15 (Jeetuwala Road) - 2 no.(27.50 HP)B/Stn. - 17 (Khakhi Baba Mandir) - 2 no. (45 HP) B/Stn. - 18 (Patram Gate) - 2 no. (15 HP) B/Stn. - 21 (Hanuman Dhani) - 2 no. (50 HP) B/Stn. - 22 (New H.B. Colony) - 2 no. (15 HP) B/Stn. - 23 (Ramganj) - 2 no. (30 HP) |
| 77 | Credit of existing outlived Panel Boards and cables etc. (At 2nd W/W, MBS and its B/Stn.)At 2nd water works for WTP-1 (R/W pump) - 2 no. (75 HP) At 2nd water works for WTP-2 (R/W pump) - 2 no. (150 HP) At 2nd water works (C/W pump) - 2 no. (20 HP)At MBS Dadri road (C/W pump) - 3 no. (200 HP)B/Stn. - 11 (Lajpat Nagar) - 2 no. (45 HP) B/Stn. - 12 (TIT B/stn.) - 2 no. (40 HP) B/Stn. - 13 (Durga colony) - 2 no. (50 HP) B/Stn. - 15 (Jeetuwala Road) - 2 no.(27.50 HP)B/Stn. - 17 (Khakhi Baba Mandir) - 2 no. (45 HP) B/Stn. - 18 (Patram Gate) - 2 no. (15 HP) B/Stn. - 21 (Hanuman Dhani) - 2 no. (50 HP) B/Stn. - 22 (New H.B. Colony) - 2 no. (15 HP) B/Stn. - 23 (Ramganj) - 2 no. (30 HP) |
| 78 | Credit of existing outlived pump sets. (At 3rd W/W and its B/Stn.)At 3rd water works (R/W pump) - 3 no. (40 HP) At 3rd water works for direct supply (C/W pump) - 3 no. (60 HP) At 3rd water works for B/Stn.(C/W pump) - 3 no. (60 HP)B/Stn. -28 (Defence Colony) - 2 no. (60 HP) B/Stn. -29 (Bank colony) - 2 no. (60 HP) B/Stn. -30 (Laxmi Nagar) - 2 no. (50 HP) B/Stn. -32 (Dhobhi colony) - 2 no. (50 HP) B/Stn. -33 (Mc colony) - 2 no. (50 HP) |
| 79 | Credit of existing outlived Panel Boards and cables etc. (At 3rd W/W and its B/Stn.)At 3rd water works (R/W pump) - 3 no. (40 HP) At 3rd water works for direct supply (C/W pump) - 3 no. (60 HP) At 3rd water works for B/Stn.(C/W pump) - 3 no. (60 HP) B/Stn. -28 (Defence Colony) - 2 no. (60 HP) B/Stn. -29 (Bank colony) - 2 no. (60 HP) B/Stn. -30 (Laxmi Nagar) - 2 no. (50 HP) B/Stn. -32 (Dhobhi colony) - 2 no. (50 HP) B/Stn. -33 (Mc colony) - 2 no. (50 HP) |
| 80 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 5500 LPM x 40.00 M Head ( For Lajpat Nagar B/stn.) |
| 81 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 82.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Lajpat Nagar B/STN.) |
| 82 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 17.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Tit Colony B/Stn.) |
| 83 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 85 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Durga Colony B/STN.) |
| 84 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 5700 LPM x 40.00 M Head ( For Durga Colony B/stn. ) |
| 85 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 30 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Jeetuwala Johar B/STN.) |
| 86 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 3300 LPM x 40.00 M Head (For Dadri road B/Stn. at MBS) |
| 87 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Dadri road B/Stn. at MBS) |
| 88 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 5200 LPM x 40.00 M Head (For Khakhi Baba Mandir B/Stn.) |
| 89 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 77.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Khakhi Baba Mandir B/Stn.) |
| 90 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 2900 LPM x 40.00 M Head (For Pat Ram gate B/Stn.) |
| 91 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 45 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Pat Ram gate B/Stn.) |
| 92 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 82.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Bansi Lal Park B/STN.) |
| 93 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 5500 LPM x 40.00 M Head ( For Bansi Lal Park B/stn. ) |
| 94 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 4100 LPM x 50.00 M Head (For Defence Colony B/Stn.) |
| 95 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 77.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Defence Colony B/Stn.) |
| 96 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 4200 LPM x 40.00 M Head (For Bank Colony B/Stn.) |
| 97 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 62.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Bank Colony B/Stn.) |
| 98 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 8100 LPM x 40.00 M Head (For Laxmi Nagar B/Stn.) |
| 99 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 120 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Laxmi Nagar B/Stn.) |
| 100 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 110 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Dhobi Colony B/Stn.) |
| 101 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 7300 LPM x 40.00 M Head (For Dhobi Colony B/Stn.) |
| 102 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 6000 LPM x 40.00 M Head (For M.C Colony B/Stn.) |
| 103 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 90 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For M.C Colony B/Stn.) |
| 104 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 3400 LPM x 40.00 M Head (For Dabar colony B/Stn.) |
| 105 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 52.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Dabar colony B/Stn.) |
| 106 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 18000 LPM x 25.00 M Head (At 2nd W/W for Line-2) |
| 107 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 9200 LPM x 40.00 M Head (At 2nd W/W for Line-1) |
| 108 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 137.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 2nd W/W for Line-1) |
| 109 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 167.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 2nd W/W for Line-2) |
| 110 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 110 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 3rd W/W for C/W) |
| 111 | Less credit for old bricks bats @ 40% ( Cum ) Total 441.60 x 40% = 176.64 Cum |
| 112 | Less credit for old Good bricks 441.60 x 60% = 264.96 @ 480 brick per cum = 127181 Bricks |
| 113 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 150 mm, installed at pump End / Source. (Inlet Flowmeter at 2nd and 3rd W/W B/Stns.: Grain Market, Defence colony) |
| 114 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 200 mm, installed at pump End / Source. (IInlet Flowmeter at 2nd and 3rd W/W B/Stns.: Tit B/Stn.,Patram Gate, Pipal wali johri, Ramganj, Civil hospital) |
| 115 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 250 mm, installed at pump End / Source. (Inlet Flowmeter at 2nd and 3rd W/W B/Stns.: Lajpat Nagar, Dabar Colony, Jeetuwala Johar, B/Stn. MBS at Dadri Road, Khakhi Baba Mandir, Bansi Lal park, Bank Colony, Laxmi nagar) |
| 116 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 300 mm, installed at pump End / Source. (Inlet Flowmeter at 2nd and 3rd W/W B/Stns.: Lajpat Nagar, Durga Colony, Hanuman Dhani, New housing board colony, Dhobi colony, MC colony) |
| 117 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 600 mm, installed at pump End / Source. (Inlet Flowmeter at MBS dadri Road) |
| 118 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 150 mm, installed at pump End / Source. (outlet Flowmeter at 2nd and 3rd W/W B/Stns.: Hanuman Dhani, Pipal wali johri, Patram Gate) |
| 119 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 200 mm, installed at pump End / Source. (outlet Flowmeter at 2nd and 3rd W/W B/Stns.: Bank colony, Ramganj, New housing board colony, Hanuman Dhani, Pipal wali johri, Patram Gate, Durga colony) |
| 120 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 250 mm, installed at pump End / Source. (outlet Flowmeter at 2nd and 3rd W/W B/Stns.: Bank colony, New housing board colony, Tit B/Stn.) |
| 121 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 300 mm, installed at pump End / Source. (outlet Flowmeter at 2nd and 3rd W/W B/Stns.: Defence colony, Khakhi Baba mandir, Durga colony, Dabar colony, Jeetuwala Johar, B/Stn. at MBS Dadri road) |
| 122 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 350 mm, installed at pump End / Source. (outlet Flowmeter at 2nd and 3rd W/W B/Stns.: MC colony, Dhobi colony,Lajpat nagar) |
| 123 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 400 mm, installed at pump End / Source. (outlet Flowmeter at 2nd and 3rd W/W B/Stns.: Laxmi Nagar, Bansi Lal park) |
| 124 | DI PIPE : Supply of Ductile iron (DI) ISI marked K9 (grade S and S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joint as per IS:5382-1985 (excluding special accessories) complete including all material, labor, hydraulic tsting and commissioning as per technical specifications and as per direction of Engineer. (Date: 8-12-2025) 300 mm i/d (Including 3% storage charges) ... |
| 125 | `RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked ` 8700 LPM x 15.00 M (At 3rd W/W for R/W) ... |
| 126 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 7300 LPM x 40.00 M Head (At 3rd W/W for C/W) ... |
| 127 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 150 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At MBS Dadri road)..... |
| 128 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 13500 LPM x 30.00 M Head (At MBS Dadri road).... Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |