| 1 | 40 mm thick cement concrete flooring 1:2:4 (1cement: 2sand: 4graded stone aggregate 40mm nominal size) laid in one layer finished with a floating coat of neat cement . |
| 2 | Repairs to patches of 2.50 Sqm and under 10 to 15 mm thik including cutting the patch in proper shape and replastering the surface of the wall including disposal of rubbish to the dumping ground within a lead of 20 metres with cement Mortar 1:3 (1 Cement 3: sand) (excluding cost of cement). |
| 3 | White washing with lime on undecorated wall surface (two coat) to give an even shade i/c throughly brooming the surface to remove all dirt, dust, mortar dirt and other foreign matter. |
| 4 | Painting two coats (Excluding priming coat) on new steel work based surfaces, with ready mixed paint brushing to give an even shade including cleaning of all dirt dust and other foreign matter sand papering and stopping with paint other than white. |
| 5 | Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on decorated wall surface ( one coat ) to give an even shade after hroughly brushing the surface to remove all dirt , remains of loose powered material . |
| 6 | Demolition of pump house slab including all leads and lifts and as per directionof Engineer-in-Charge. |
| 7 | Providing and laying cement concrete 1 : 1.5 : 3 ( 1 cement : 1.5 : sand : 3 graded stone aggregate 20mm nominal size ) and curing complete excluding cost of form work and reinfocement for reinforced work in foundation footings bases of colums and the like and mass concrete i/c carriage of material upto all lifts and as per direction of Engineer-in-Charge. |
| 8 | Providing & Placing of Tor steel reinforcement for RCC work including bending binding and placing in position complete including carriage of materials with in all leads and lifts. |
| 9 | Wiring for light / Fan point / Exhaust fan point / call bell point with 1.5 Sq.mm PVC insulated heat resitant flame retardent ( HRFR ) of low smoke single core ( flexible ) copper conductor cable in PVC casing and capping and earthing the light point with 1.5 sq.mm HRFRLS / PVC insulated single Group \\" C \\" as required, required including carriage of all material within all leads and lifts . |
| 10 | Wiring for light / power plug with 2 x 4 Sq.mm PVC insulated heat resistant flame retardent ( HRFR ) and low smoke single core ( flexible ) copper conductor cable in PVC casing and caping along with 1 no , 4sq . mm HRFRLS / PVC insulated single core copper as required including carriage of materials within all leads and lifts . |
| 11 | Wiring for light / power plug with 4 x 4 Sq.mm PVC insulated heat resistant flame retardent ( HRFR ) and low smoke single core ( flexible ) copper conductor cable in PVC casing and capping along with 2no , 4sq . mm HRFRLS / PVC insulated single core copper as required including carriage of materials within all leads and lifts . |
| 12 | Wiring for light / power plug with 2 x 1.5 Sq.mm PVC insulated heat resistant flame retardent ( HRFR ) and low smoke single core ( flexible ) copper conductor cable in PVC casing and capping along with 1 no , 4sq . mm HRFRLS / PVC insulated single core copper conductor cable as required including carriage of materials within all leads and lifts . |
| 13 | Wiring for circuit / sub main wiring with 4 x 1.5 Sq.mm PVC insulated heat flame retardent ( HRFR ) and low smoke single core ( flexible ) copper conductor cable PVC Casing & capping along with 2 no , 2.5sq . mm ( 4x2.5 + 2x2.5 ) HRFRLS / PVC insulated single core copper conductor cable as required including carriage of materials within all leads and lifts . |
| 14 | Supplying and fixing metal box of 100 x 100 x 60mm deep ( Nominal size ) on surface / recess with suitable size phonolic leminated sheet cover fixing 3 pin 15/16 amps socket tumber / piano type switch connections painting etc. including carriage of materials within all leads and lifts |
| 15 | S/F of 6 amps to 63 amps rating 10 KA breaking capacity 240 Volts , \\" C \\" curves miniature circuit breaker of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required including carriage of materials within all leads and lifts Category - A single pole . |
| 16 | Supplying and fixing 40 Amps / 50 amps / 63 Amps rating 10 KA breaking capacity 240 Volts \\" C \\" curves miniature circuit breaker of following poles in the existing MCB DB complete with connections , testing and commissioning etc. as required including carriage of material within all leads and lifts .Double pole Category- B 63 Amps . |
| 17 | Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts , on surface / recessed complete with tinned , copper busher neutral link , earth bar , din bar , detachable gland plate , interconnections , including painting , earthing etc. as required : bus bar 8 way . |
| 18 | Providing , installing , testing and commissioning of 12 watt -LED Lamp . |
| 19 | Providing , installing , testing and commissioning of ceiling fan and regulator including wiring the rod of standard length ( upto 30 cm ) with 1.5 Sqmm PVC insulated copper conductor single core cable etc.as required 1200 mm sweep.Category A |
| 20 | Providing,installing testing and commissioning of 1X36 watt-FTL(T8) shock proof slim (categary \\"A\\" including wiring with 1.5 Sq mm PVC insulated copper conductor single core cable etc.as required. |
| 21 | Providing and laying service cable 16mm2, 2core aluminium including all leads and lifts. Please Enable Macros to View BoQ information |