| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceed 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottom, lift upto 1.5 m, including getting out the excavated soil and disposal surplus excavated soil as directed, within a lead of 50 m. |
| 2 | 2.8.1 All kind of Soil |
| 3 | Random rubble masonry with hardstone in foundation and plinth including levelling up with cement concrete 1:6:12 (1cement : 6 coarsesand : 12 gradedstone aggregate 20 mm nominal size) upto plinth level with : |
| 4 | 7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site. |
| 6 | Toilets |
| 7 | Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minium depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately) |
| 8 | Toilets |
| 9 | Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade |
| 10 | 7.12.2.2 White sand stone |
| 11 | Providing wood work in frames of false ceiling, partitions etc.sawn and fixed in position with necessary stainless steel screws etc. |
| 12 | 9.3.1 Sal wood |
| 13 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately). |
| 14 | 9.1.2 Sal wood |
| 15 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: |
| 16 | 9.7.1 Second class teak wood |
| 17 | 9.7.5.4 Pre-laminated particle board with decorative lamination on both sides, Grade-1, typeII.IS:12823 marked |
| 18 | 9.7.7.1 4mm thick glass pane (weight not less than 10 kg per sqm) |
| 19 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embending in cement concrete block 1;3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 20 | no. of items |
| 21 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete: |
| 22 | 9.55.1 125x65x2.12 mm Doors And Windows |
| 23 | 9.55.3 75x47x1.70 mm Ventilators |
| 24 | Providing & fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: |
| 25 | 9.96.1 300x16mm |
| 26 | Providing & fixing aluminum tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 27 | 9.97.1 300x10mm |
| 28 | 9.97.4 150x10mm |
| 29 | Providing & fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 30 | 9.100.1 125mm |
| 31 | 9.100.2 100mm |
| 32 | Providing & laying 1st quality Ceramic glazed floor tiles conforming to IS: 15622 (thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, rises of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 33 | Total Area |
| 34 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : |
| 35 | 17.5.2 Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern |
| 36 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 37 | 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 38 | 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. . |
| 39 | no. of mirrors |
| 40 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 41 | 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 42 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 43 | 8.10.2 Granite stone of approved shade |
| 44 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 45 | 100 mm dia PVC pipe for soil and waste pipe |
| 46 | 75 mm dia PVC pipe for waste water |
| 47 | floor trap |
| 48 | 100 mm bend PVC |
| 49 | 100 mm T PVC |
| 50 | 75 mm bend PVC |
| 51 | 75 mm T PVC |
| 52 | 20mm CPVC pipes |
| 53 | 20mm bend |
| 54 | 20mm CPVC T joint |
| 55 | Providing electrical work which iincludes wiring, lighting, electrical conduit pipes, switch boards, exhaust fans etc. (based on market rates) |
| 56 | 1. Exhaust fans |
| 57 | 2. switch boards (12 Module) with switches and 1 socket |
| 58 | 3. switch boards (8 Module) with switches and 1 socket |
| 59 | 4. Wire 1.5 |
| 60 | 5. Wire 2.5 |
| 61 | 6. PVC Conduit |
| 62 | 7. Lighting Fixtures |
| 63 | 8. MCB Board |
| 64 | 9. Labour Charges |
| 65 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portioninside grooves or rebates to be measured).Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 66 | 9.7.5.4 Pre-laminated particle board with decorative lamination on both sides,Grade I, Type II, IS:12823 marked |
| 67 | Slate roof covering |
| 68 | Provide natural slate roofing tiles (selected grade for weather resistance and consistent thickness). Lay underlayment membrane (breathable/waterproof), battens/purlins, and fix slates with corrosion-resistant nails/fixing including carriage Please Enable Macros to View BoQ information |