| 1 | Clearing and Grubbing Road LandClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees having girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of erviceable material up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness.A) In area of light jungle |
| 2 | Embankment/ Sub Grade Construction with Material Obtainedfrom Borrow Construction of embankment with approved material having CBR>7obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and ompacting to meet requirement of table 300-1, 300-2 and as per relevant clauses of section-300. |
| 3 | Crusher Run Macadam Sub Base/Base CourseProviding crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller as per clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications(ii) For 37.5 mm maximum size |
| 4 | Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13 and as per clause of section 406 of Specifications.A By Sensor Paver |
| 5 | Deduction for item No.4.3 if sensor paver is not used |
| 6 | Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting on OMC using vibratory roller of 80 to 100 kN static weight. Field compaction shall be done in corresponding layers of carriage way thickness and meet the requirements of MDD to achieve compaction (98% -100%) as per relevant clause of 408A) Hard Shoulders (CBR value >12) |
| 7 | Prime Coat Over WMM/WBMProviding and applying primer coat with catonic bitumen emulsion on prepared surface of granular Base including cleaning of road surface and spraying primer at the rate of 0.70 to 1.00 kg/sqm using mechanical means as per clause 502 of specifications. |
| 8 | (ii) Providing and applying tack coat with cationic bitumen emulsion using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications.(ii) @0.30 kg per sqm (dry & hungry bituminous surfaces /Granular surfaces treated with primer |
| 9 | Bituminous MacadamProviding and laying bituminous macadam using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with Electronic Sensor paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction and asper clause 504 of specifications. B) Using Batch Mix Plant of appropriate capacity and Hydraustatic Paver finisher with Sensor. (ii) for Grading (19 mm nominal size) bitumen content 3.5% with bitumen 60/70 (VG 30) |
| 10 | Open - Graded Premix Surfacing Providing, laying and rolling of open - graded premix surfacing of20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tone capacity, finished to required level and grades all complete as per clause 510 of specification. (i) Case - I: Mechanical method using Penetration grade Bitumen VG 30 and HMP of appropriate capacity not lessthan75 tones/hour. |
| 11 | Seal CoatProviding and laying seal coat, sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats, all complete as per clause 511 of Specification.(ii) Case - II: Type B (Providing and laying of premix sand seal coat using HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping (aggregate shall pass 2.36mm sieve and retained to 180- micron sieve) and penetration bitumen VG 30 of suitable grade all complete as per clause 511 of specification. |
| 12 | Kilo Metre StoneReinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc(ii) Ordinary Kilometer stone (Precast) |
| 13 | (iii) Hectometer stone (Precast) |
| 14 | Retro- reflectorised Traffic signsProviding and fixing of retro-reflectorised autionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic rade Sheeting (Type XI) vide IRC: 67:2022 clause 6.7.4.3 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT&H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four inimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by thecontractor. iv) 60 cm equilateral triangle |
| 15 | ix) 80 cm x 60 cm rectangular |
| 16 | xii) 60 cm x 45 cm rectangular |
| 17 | Direction and Place Identification signs more than 0.9 sqm size board.Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT&H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on 2 nos. of MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor |
| 18 | Road Marking with Hot Applied Thermoplastic Compoundwith Reflectorizing Glass Beeds on Bituminous surface.Providing and applying (Cleaning of Bituminous surface)thermoplastic compound having composition of binder (Resin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35.The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications. Note: - The guarantee of Thermoplastic should be minimum3 Years. |
| 19 | Providing and laying reinforced cement concrete pipe NP-4 for service ducts below concrete pavement.a) 300 mm Dia |
| 20 | Excavation for StructuresEarth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 in I Ordinary soil (including back filling with approved material) Below pipe Face wall |
| 21 | PCC M-15 in FoundationPlain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409 |
| 22 | Providing and Laying Reinforced Cement Concrete PipeNP4/prestrssed concrete pipe on first class bedding in single row.Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.(B) 1000 MM Dia |
| 23 | Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.Folundation Base |
| 24 | Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with.(i) Concrete with plant (Drum Type) and placingB)PCC Grade M20cum |
| 25 | Providing and Laying Reinforced cement concrete pipe NP4 / prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in triple row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets and as per relevant clauses of section-2900.A) 1000 mm dia pipe |
| 26 | Add for every additional row in item 9.4 aboveB) 1000 mm dia pipe Please Enable Macros to View BoQ information |