SITC OF HI WALL 1.0 TR SPLIT SYSTEMS AND BUYBACK OF HI WALL SPLIT AC
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners 1.0 tr split ac complete with Indoor unit, Out door unit , surface or concealed copper Refrigerant piping with insulation closed cell elastomeric nitrile rubber tubular pipe section upto 3 Mtr IDU to ODU, copper power cable upto 3.5 Mtr IDU to ODU ic drain pipe R32 or R410 or R407 Green Refrigerant,wireless Remote control, suitable for working between 180 to 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll or rotarycompressor. The system shall be able to deliver 100PERCENTAGE of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer warranty both compressor and Printed Circuit Board . Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission IEC 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS 1391 Part II 2023. The system shall be able to operate up to 50 Degree C out door ambient temperature. Buy Back of OLD AC Units on wherein whereas basis.
2
COPPER REFRIGERANT PIPING for 1.0 TR HI WALL SPLIT AC
Supplying, Installation, testing , commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class O tubular insulation or with Class O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia OD Soft drawn with tube thickness 1.2 mm and 12.7 mm dia OD Soft drawn with tube thickness 1.2 mm for 1.0 TR HI WALL SPLIT along with power cable of required size.
3
DRAIN PIPE
Supply and fixing of duly insulated 25mm UPVC drain pipe
4
OUTDOOR STAND for 1.0 TR HI-WALL SPLIT AC
Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.0 TR Hi-Wall Split AC.
5
FIXING OF REMOTE HOLDER IN THE WALL
Supplying and Installation of remote holder on the wall in the each room and making good all the damage .