| 1 | APPENDIX A-SUPPLY AND INSTALLATION OF 320 KVA DIESEL GENERATOR SET |
| 2 | OD385605/2025-2026:Supply, conveyance, Installation, Testing and commissioning of 320KVA Diesel Generator set with standard control panel integral with acoustic enclosure keeps 75 db at 1 mtr as per CPCB IV + norms with standard accessories as per technical details given below . A. Engine (i) . Make of Engine - Kirloskar/cummins/Volvo/Cater Pillar (ii). Type of Engine - Diesel engine . No. of cylinders - As per manufacturers standards. (iv) . Method of cooling- Water cooled with radiator. (v). Design - suitable for generating set operation. (vi). Standard accessories with Diesel Engine :- a). Flywheel b). close coupling C). Air cleaner d). Radiator with fan provided with fan guard e). fuel pump f).fuel filter h). lubrication oil filter i). Battery charger / generator (vii) . Engine instrument panel and engine control with microprocessor based display, integrable with AMF and communicating compatible (viii). DEF tank (ix) . Exhaust gas treatment system (x). Diesel tank capacity of minimum 600 liter or as per manufacturers standards inbuilt with the acoustic enclosure. (xi) . Engine output - 380Bhp or as per manufacturers standards B. Alternator . a). Make :- Kirloskar/KEL/Stamford/LEROYSOMER b). Type :- Self excited and self regulated c). Capacity :- 320KVA/256 KW at 0.8 pf d). System voltage :- 3 phase , 415 V e). Frequency :- 50 Hz f). Insulation :- Class F/H . The alternator should confirm to IP 4722.g). Load test shall be conducted on the 320KVA DG set in various step loads i.e., at half load, 80% load , full load for One and half hours and 10% overload for 20 minutes. The test certificate should be produced in standard format from the manufacturers. |
| 3 | OD387671/2025-2026:Supply , conveyance ,Installation ,testing and commissioning of of AMF control panel using 1.6mm CRCA sheet powder coating, suitable for 320 KVA Diesel Generator set with all standard control accessories including 2 Nos.500A 4 pole , 36 KA microprocessor based MCCB's ,power contactors of rated amperes , Mechanical interlock , LED phase indication lamps with 2A SPMCB's , Danger notice board, Legend plates etc.as required. |
| 4 | OD387715/2025-2026:Dismantling the existing Kirloskar make 160 KVA DG set without making any damages, dismantling the engine, alternator etc. convey the DG set from Medical college hospital to SAT hospital safely, unloading and keep it in a safe position as directed by the engineer at site. |
| 5 | OD387710/2025-2026:Charges for dismantling the existing old and damaged control panels and convey the same to a convenient location as directed by the engineer in charge. |
| 6 | OD391226/2025-2026:Supply and clamping the following size of B class MS pipes with accessories on surface of walls or on prefabricated angle iron structure with clamps or brackets , painting the entire unit with 2 coats of aluminium paint making good the damages etc.as required. 6" (150mm) dia B class MS pipe |
| 7 | OD391284/2025-2026:Supply and clamping the following size of B class MS pipes with accessories on surface of wall or on prefabricated angle iron structure with clamps or brackets, painting the entire unit with 2 coats of aluminium paint making good the damages etc as required 8" (200mm) dia B class MS pipe |
| 8 | OD391337/2025-2026:Supply and providing cladding to the silencer of the DG set using aluminium sheet filled with resin bounded fiber glass wool to dissipate heat etc as required . |
| 9 | OD391338/2025-2026:Supply and providing cladding to the exhaust system of the DG sets on the MS Pipe already installed on walls / prefabricated structure using aluminium sheet filled with resin bounded fibre glass wool to dissipate heat etc as required |
| 10 | OD393965/2025-2026:Supply, Installation, Testing and Commissioning of 200/5VA accuracy class 1, resin cast metering CT |
| 11 | OD393966/2025-2026:Supply and fixing Red, green, Blue, Yellow, Orange colours LED Indicator , AC/DC as required |
| 12 | OD393967/2025-2026:Supply and fixing Three phase Digital Ammeter (A- R, Y, B) of accuracy class 0.50 |
| 13 | OD393968/2025-2026:Supply and fixing three phase digital voltmeter (V-RY, YB, BR, R, Y, B) of accuracy class 0.50 |
| 14 | OD394017/2025-2026:Supply and fixing 2A HRC Fuse Link |
| 15 | OD394018/2025-2026:Supply and fixing Digital Frequency Meter |
| 16 | OD394019/2025-2026:Supply and fixing 2A single pole MCB |
| 17 | APPENDIX B- PANEL FABRICATION AND ELECTRIFICATION |
| 18 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 19 | 90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 20 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 21 | 90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) |
| 22 | 90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. |
| 23 | 90.14.7:Supply and providing copper earth bus in the panel board |
| 24 | OD394065/2025-2026:Supply and fixing 2A single pole MCB |
| 25 | OD388431/2025-2026:Supply, Installation, Testing and Commissioning of 200/5VA accuracy class 1, resin cast metering CT |
| 26 | OD388432/2025-2026:Supply and fixing Red, green, Blue, Yellow, Orange colours LED Indicator , AC/DC as required |
| 27 | OD388489/2025-2026:Supply & Fixing three phase digital Multifunction meter |
| 28 | OD388492/2025-2026:Painting letters or figures of 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB , DB panel board etc. as required |
| 29 | OD388933/2025-2026:Supply and providing 8 way MCCB Load bank sub main distribution board with IP 42 protection complying to IEC 61439-2 with copper bus ,neutral link, earth bus etc. suitable for providing 3 pole incoming and outgoing fixed on wall using necessary anchor bolt including cutting hole on the wall , making good the damages, colour washing etc. as required. [L & T Enersys or Equivalent. |
| 30 | OD388934/2025-2026:Supply and installation of Side Cabling Box TN 250D Category No. CM910850F00 of 250A 8 way compliance with latest standards IEC 61439-2 of SMDBs power distribution. |
| 31 | OD388935/2025-2026:Supply and installation of Corner Box TN 2500 Category No. CM910890000 of 250A 8 way compliance with latest standard IEC 61439 2 of SMDBs power distribution. |
| 32 | OD388936/2025-2026:Supply and installation of Metering Extension Box TN 250D Category No. CM9043900PO of 250A 8 way compliance with latest standard IEC 61439-2 of SMDBs power distribution. |
| 33 | OD388937/2025-2026:Supply and installation of Bottom Cabling box TN250D Category No. CM90437ocoo of 250A 8 way compliance with latest standard IEC 61439 - 2 of SMDBs power distribution. |
| 34 | OD388938/2025-2026:Supply and fixing Three phase Digital Ammeter (A- R, Y, B) of accuracy class 0.50 |
| 35 | OD388939/2025-2026:Supply and fixing three phase digital voltmeter (V-RY, YB, BR, R, Y, B) of accuracy class 0.50 |
| 36 | OD389047/2025-2026:Supply and fixing the following rating 250A,4 pole ,415V , 50Hz Automatic Transfer Switches (ATS) in the existing panels. |
| 37 | OD389061/2025-2026:Supply and fixing 400A,415V,50Hz, Automatic Transfer Switches(ATS) in the existing panels. |
| 38 | OD389076/2025-2026:Supply and fixing315A,415V,50Hz, Automatic Transfer Switches(ATS) in the existing panels. |
| 39 | 90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 40 | 90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 41 | 90.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 42 | 90.14.10.17:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.320A/400A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 43 | 90.14.10.18:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 44 | 90.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A |
| 45 | 90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A |
| 46 | 90.14.11.7:MCCB AccessoriesSupply and fixing 630 - 800A earth fault module of MCCB requiring external CBCT. |
| 47 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 48 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 49 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 50 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 51 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 52 | 90.3.20.4:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture |
| 53 | APPENDIX C - CABLING |
| 54 | 90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 55 | 90.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm |
| 56 | 90.12.7.35:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm |
| 57 | 90.12.7.36:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm |
| 58 | 90.12.7.38:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp |
| 59 | 90.12.5.32:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 120 sq mm |
| 60 | 90.12.5.35:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 240 sq mm |
| 61 | 90.12.5.36:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 300 sq mm |
| 62 | 90.12.5.38:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm |
| 63 | 90.12.6.32:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 120 sq mm |
| 64 | 90.12.6.35:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 240 sq mm |
| 65 | 90.12.6.36:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 300 sq mm |
| 66 | 90.12.6.38:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 4 sq mm |
| 67 | OD394112/2025-2026:Supply , laying and clamping of 1 No. 7 core 2.5 sq mm PVC/ XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part 1 1988 for PVC and IS 7098 part 1 for XLPE with the cables , spacing of clamps with factory made clamp not exceeding 60cms, making good the damages , colour washing etc. as required. |
| 68 | 9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 69 | 9.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 70 | 9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) |
| 71 | 9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm) |
| 72 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 73 | 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 74 | 90.16.1.5:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) |
| 75 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 76 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 77 | 90.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) |
| 78 | 90.12.10.7:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation120/102.5 mm or nearest size |
| 79 | 90.12.9.7:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench120/102.5 mm or nearest size |
| 80 | APPENDIX D- EARTHING AND HARDWARE ITEMS |
| 81 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 82 | OD391051/2025-2026:Supply and providing 2.5mm thick Elastometric fire retardant insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength including fixing with suitable synthetic adhesive. |
| 83 | OD391052/2025-2026:Supply and installation of 4Kg ABC type fire extinguisher with hose and clamps on wall and giving proper training to staff for operating the same |
| 84 | 90.16.4.8:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip |
| 85 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 86 | 90.16.2.4:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class) |
| 87 | APPENDIX E- FEES AND RECEIPTS |
| 88 | OD389210/2025-2026:Charges for preparation of electrical layout of the existing electrical installations , schematic diagrams etc. and submit the same to electrical inspectorate for approval. |
| 89 | OD389235/2025-2026:Amount to be deposited in Kerala state Electrical Inspectorate for testing of meters, Inspection, scheme approval ,energization certificate etc.( Actual amount will be re imbursed on production of documentary evidence ) Please Enable Macros to View BoQ information |