| 1 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. |
| 2 | Group C. |
| 3 | Wiring for Twin Control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with 2 Way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | Group C. |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
| 6 | 2X1.5Sq.mm+1X1.5Sq.mm Earth wire |
| 7 | 2X2.5Sq.mm+1X2.5Sq.mm Earth wire |
| 8 | 2X4 Sq.mm+1X4Sq.mm Earth wire |
| 9 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 10 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 11 | Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 12 | 3X1.5 Sq.mm |
| 13 | 3X2.5Sq.mm |
| 14 | 3X4Sq.mm |
| 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 16 | Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 17 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3Nos 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.(For light plugs to be used in NR Buildings). |
| 18 | 12 Module (200mmX150mm) |
| 19 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 20 | 5/6 amp Modular switch |
| 21 | 3 pin 5/6 amp socket outlet |
| 22 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- |
| 23 | Single pole. Cat-A. |
| 24 | Supplying & fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing & commissioning etc. as required. |
| 25 | 63 Amps. Cat-A. |
| 26 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 27 | 63 Amps. Cat-A. |
| 28 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required.(But without MCB/RCCB/Isolator). |
| 29 | Double door-16 way |
| 30 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. |
| 31 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 32 | Providing and Fixing of IP20 LED Surface mounted CRCA Powder Coated Box Type Channel with Pro LED Lamp Suitable for mounting 1 X 18 W LED Tube T8 type having minimum system efficacy of greater than 100 lm/W, P.F.>0.95 with THD<10% ,CCT 6500 K,CRI 80,Surge Protection 2 Kv.The LED with Useful life of 50000 Hrs at L70 . The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. (With 5 Years Warranty). |
| 33 | LED Tube Light 18/20 Watts |
| 34 | Providing and Fixing of IP20 LED fixture of 18 watt +/- 1 W LED Surface/Recess Mounted Downlighter Round/Square Shape with minimum system lumen efficacy of 100 lm/W with Polycarbonate housing,pressure die cast heat sink and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. (With 5 Years Warranty). |
| 35 | Surface/Recss mounted Square/Round downlighter 12Watts |
| 36 | Surface/Recss mounted Square/Round downlighter 18 Watts |
| 37 | Providing and Fixing of LED fixture 600mmX600mm 36 Watt +/- 1W Surface/Recess mounted fixture with HET Plastic diffuser with minimum system lumen efficacy of 100 lm/W with CRCA housing having P.F.>0.95 with THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects (With 5 Years Warranty). |
| 38 | LED panel 2'X2'-36 Watts |
| 39 | Supplying and fixing of bulk head fitting LED 10 watt+/-1W with minimum system Lumen efficiencyof greater than 100lm/W with and P.F.0.95 with THD,10%,CCT 5700K,CRI 70,Surge protection 4KV. The LED with useful life of 50000 Hrs. at L70. The input voltage range shall be 150V to 270V complete with all accessories, connections, testing & commissioning etc.as required. (With 5 Years Warranty). |
| 40 | LED 10 Watt Bulk Head |
| 41 | Supplying and fixing of LED Flood light Luminaire comprises of Al Die cast Housing with frame , High Purity PC lens Diffuser,cradle mounting, minimum system lumens of 5000. The luminaire shall have CCT of 5700K and CRI of minimum 80, PF>0.95 and THD>10%. The luminaire shall have IP66 and IK08 protection. The LED shall be compliant with Useful L70 life of 50000 Hrs. Driver efficiency should be 85% to operate in input voltage range of 100V to 270V (nominal rated voltage – 240V) with 4 KV internal surge protection and 10KV external surge protection. (With 5 Years Warranty). |
| 42 | LED Flood Light Luminaire 50 Watts. |
| 43 | Providing, Installation, testing and commissioning of BLDC ceiling fan (5 star rating), including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required: |
| 44 | Ceiling Fan 1200 mm sweep, Category-A |
| 45 | Supplying and fixing extra down rod of 60cm length G.I. pipe 15mm dia heavy gauge including painting etc. as required.(Note:-More than 5cm length shall be rounded to the nearest 10cm and 5cm or less shall be ignored.) |
| 46 | Providing and installation exhaust fan of following sizes in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required: (With 5 Years Warranty). |
| 47 | Exhaust Fan, Light duty, (Domestic) 300 mm sweep |
| 48 | Providing & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 49 | Armoured cable 10 sq. mm (2 core) |
| 50 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required,but excluding sand cushioning and protective covering .Armoured cable 10sq. mm. (2 core: |
| 51 | Acceptable Make. |
| 52 | E.I. Work |
| 53 | PVC insulated FRLS copper Conductor Wires:Polycab/Havells/KEI/RR Kabel/Finolex/plaza. |
| 54 | U.G. Cables:Polycab/Havells/KEI/RR Kabel/ Finolex/ plaza. |
| 55 | Modular Switch & Socket, GI Box & Modular Plate, Step Type Regulator / industrial socket i/c Cat 6 I/O Switch:Legrand/Siemens/Schneider/ABB/North West/Lauritz Knudsen (Formerly L&T)/Honeywell |
| 56 | DB, MCB, RCBO, ISOLATOR, LOOSE WIRE BOX:Legrand/Siemens/Schneider/ABB /Lauritz Knudsen (Formerly L&T) |
| 57 | Ceiling Fan/Heavy duty exhaust fan/Ventilation Fan:Crompton/ USHA/Havells/ Orient/bajaj. |
| 58 | Geyser:Havells/AO-Smith/Racold/Bajaj |
| 59 | LED luminaries::Philips/Havells/Wipro /LT/Regent/Bajaj/Jaquar |
| 60 | Octagonal Pole:Valmont/Transrail/Skipper/Bajaj/Philips/Twinkle/Mayfair(lux max). |
| 61 | M.S. Pipe/G.I. Pipe:Jindal (Hissar) /Tata/SAIL/Prakash Surya (duly ISI Marked) |
| 62 | DWC HDPE Pipe:TeleRex/Gemini/Supreme/Duraline (duly ISI Marked) |
| 63 | Double Brass compression gland / Thimbles:Dowells/Action/Gripwell/Comet/Jainson/Braco |
| 64 | MCCB (It should be Ics = Icu = 100%):Lauritz Knudsen (Formerly L&T) (D Sine) /Siemens (3VA) / ABB (Tmax) / Schneider (Compact NSX) / Legrand (DPX3) |
| 65 | SCHNEIDER (NW) / SIEMENS (3WT) / ABB (E-MAX)/ Lauritz Knudsen (Formerly L&T) (U POWER OMEGA) / LEGRAND ( DMX3) |
| 66 | LT Panels / Outdoor Feeder Pillar (Non TTTA Type):Adlec/ Tricolite/Precision/ Advance Panel & Switch Gear / /ASPL/ Milestone/ Pristine/ DSPL/ KSB Electric cxompany/Harc Power |
| 67 | Digital Instruments:AE/ Lauritz Knudsen (Formerly L&T)/Schneider/Siemens/ Trinity/ Conzerve/ ABB |
| 68 | CT & PT:AE/Kappa/Matrix/EPCOS/ Lauritz Knudsen (Formerly L&T) /ABB/ Schneider/Gilberts & Maxwell |
| 69 | Contactors & Overload Relays:Lauritz Knudsen (Formerly L&T) / Siemens /ABB/Schneider |
| 70 | Indicating Lamps:Lauritz Knudsen (Formerly L&T) / Siemens /C&S/ Schneider/ABB |
| 71 | Timer switch:Lauritz Knudsen (Formerly L&T) /Siemens/ ABB / Schneider / Legrand |
| 72 | Connectors/ Terminal Blocks:Elmex / Connectwell / Essen/ SCHNIEDER/ Lauritz Knudsen (Formerly L&T) |
| 73 | RO Water Purification:KENT/Aquaguard/Livpure/Eureka Forbes Please Enable Macros to View BoQ information |