| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. DSR 2.8 |
| 2 | All kinds of soil. DSR 2.8.1 |
| 3 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : DSR 2.10 |
| 4 | All kinds of soil. DSR 2.10.1 |
| 5 | Pipes, cables etc. exceeding 80 mm dia. DSR 2.10.1.1 |
| 6 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia DSR 2.10.1.2 |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : DSR 4.1 |
| 8 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) DSR 4.1.3 |
| 9 | 1:5:10 (1 cement : 5 fine sand derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 4.1.11 |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excludingthe cost of centering, shuttering, finishing and reinforcement, with 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size).DSR 5.3 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for :DSR 5.9 |
| 12 | Suspended floors, roofs, landings, balconies and access platform DSR 5.9.3 |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. DSR 5.22 |
| 14 | Thermo-Mechanically Treated bars DSR 5.22.6 |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: DSR 6.1 |
| 16 | Cement mortar 1:4 (1 cement : 6 coarse sand) DSR 6.1.2 |
| 17 | 12 mm cement plaster finished with a floating coat of neat cement of mix : DSR 13.7 |
| 18 | 1:3 (1 cement: 3 fine sand) DSR 13.7.2 |
| 19 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 20 | Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) DSR 15.2.1 |
| 21 | Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :DSR 15.43 |
| 22 | Water bound macadam road DSR 15.43.1 |
| 23 | Bituminous road DSR 15.43.2 |
| 24 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 25 | 300 mm dia. R.C.C. pipe DSR 19.6.4 |
| 26 | 250 mm dia. R.C.C. pipe DSR 19.6.3 |
| 27 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 DSR 19.19 |
| 28 | H D - 20 DSR 19.19.3 |
| 29 | Circular shape 560 mm internal diameter DSR 19.19.3.1 |
| 30 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : DSR 19.21 |
| 31 | For pipes 250 to 300 mm diameter DSR 19.21.2 |
| 32 | Providing and fixing of RCC Road Gully Cover with frame etc complete in in all respects. Please Enable Macros to View BoQ information |