| 1 | SITC of Analgue Addressable 1 loop control Panel all as specified in srl no 1 of Appendix A | SITC of Analgue Addressable 1 loop control Panel all as specified in srl no 1 of Appendix A |
| 2 | SITC of Analogue Addressable Multi Sensor with baseall as specified in srl no 1 of Appendix A | SITC of Analogue Addressable Multi Sensor with baseall as specified in srl no 1 of Appendix A |
| 3 | SITCofAnalogue Addressable Manual Call Point all as specified in srl no 3 of Appendix A | SITCofAnalogue Addressable Manual Call Point all as specified in srl no 3 of Appendix A |
| 4 | SITCof Intelligent Loop Powered Wall Sounder Beacon with base all as specified in srl no 4 of Appendix A | SITCof Intelligent Loop Powered Wall Sounder Beacon with base all as specified in srl no 4 of Appendix A |
| 5 | S AND L 2 CORE 1 POINT 5 sqmm fire alarm armoured cable all as specified in srl no 5 of Appendix A | S AND L 2 CORE 1 POINT 5 sqmm fire alarm armoured cable all as specified in srl no 5 of Appendix A |
| 6 | SITC of Industrial Ductable Super Cooler all as specified in srl no 6 of Appendix A | SITC of Industrial Ductable Super Cooler all as specified in srl no 6 of Appendix A |
| 7 | M AND L for Fabrication Installation Balancing of Site fabricated GSS sheet metal rectangular ducting all as specified in srl no 7of Appendix A | M AND L for Fabrication Installation Balancing of Site fabricated GSS sheet metal rectangular ducting all as specified in srl no 7of Appendix A |
| 8 | M AND L for XLPE insulation High quality XLPE Aluminum with form 9mm insulation for duct all as specified in srl no 8of Appendix A | M AND L for XLPE insulation High quality XLPE Aluminum with form 9mm insulation for duct all as specified in srl no 8of Appendix A |
| 9 | S and F of Imported Air Grills with auto swing all as specified in srl no 9 of Appendix A | S and F of Imported Air Grills with auto swing all as specified in srl no 9 of Appendix A |
| 10 | S and F of Lack Phase Voltage Power Fluctuation all as specified in srl no 10 of Appendix A | S and F of Lack Phase Voltage Power Fluctuation all as specified in srl no 10 of Appendix A |
| 11 | SFC of fire retardant anti vibration canvas connector all as specified in srl no 11 of Appendix A | SFC of fire retardant anti vibration canvas connector all as specified in srl no 11 of Appendix A |
| 12 | M AND L for Iron frame stand for mounting of machine AND fixing on location all as specified in srl no 12 of Appendix A | M AND L for Iron frame stand for mounting of machine AND fixing on location all as specified in srl no 12 of Appendix A |
| 13 | M AND L for Sub main wiring with 1 core 4 Sqmm PVC insulated copper conductor all as specified in srl no 13 of Appendix A | M AND L for Sub main wiring with 1 core 4 Sqmm PVC insulated copper conductor all as specified in srl no 13 of Appendix A |
| 14 | S AND F 6 core 1 POINT 5 Sqmm copper conductor cable all as specified in srl no 14 of Appendix A | S AND F 6 core 1 POINT 5 Sqmm copper conductor cable all as specified in srl no 14 of Appendix A |
| 15 | Supply Installation of water storage tank cap 1000 ltr 3 layer all as specified in srl no 15 of Appendix A | Supply Installation of water storage tank cap 1000 ltr 3 layer all as specified in srl no 15 of Appendix A |
| 16 | S and F Including all fittings GI pipe medium grade of 20 mm dia all as specified in srl no 16 of Appendix A | S and F Including all fittings GI pipe medium grade of 20 mm dia all as specified in srl no 16 of Appendix A |
| 17 | S and F Including all fittings GI pipe medium grade of 15mm dia all as specified in srl no 17 of Appendix A | S and F Including all fittings GI pipe medium grade of 15mm dia all as specified in srl no 17 of Appendix A |
| 18 | S AND Fixing gun metal gate or stop valves with iron wheel head all as specified in srl no 18 of Appendix A | S AND Fixing gun metal gate or stop valves with iron wheel head all as specified in srl no 18 of Appendix A |
| 19 | S AND F Ball valves PTMT 20MM all as specified in srl no 19 of Appendix A | S AND F Ball valves PTMT 20MM all as specified in srl no 19 of Appendix A |
| 20 | S AND F PVC connection pipe of 15 mm bore all as specified in srl no 20 of Appendix A | S AND F PVC connection pipe of 15 mm bore all as specified in srl no 20 of Appendix A |
| 21 | S AND F PVC flexible drain pipe of size 30 all as specified in srl no 21 of Appendix A | S AND F PVC flexible drain pipe of size 30 all as specified in srl no 21 of Appendix A |
| 22 | Cutting existing road Hard Standing with width not exceeding 750 mm and 1m deep all as specified in srl no 22 of Appendix A | Cutting existing road Hard Standing with width not exceeding 750 mm and 1m deep all as specified in srl no 22 of Appendix A |
| 23 | M AND L for PCC Type B1 using 20 mm graded stone aggregate all as specified in srl no 23 of Appendix A | M AND L for PCC Type B1 using 20 mm graded stone aggregate all as specified in srl no 23 of Appendix A |
| 24 | SITC of XLPE cable sizes 4 core 16 sqmm all as specified in srl no 24 of Appendix A | SITC of XLPE cable sizes 4 core 16 sqmm all as specified in srl no 24 of Appendix A |
| 25 | M AND L for Excavation in trenches for cable laying all as specified in srl no 25 of Appendix A | M AND L for Excavation in trenches for cable laying all as specified in srl no 25 of Appendix A |
| 26 | M AND L for Returning filling including spreading leveling watering in layers not exceeding 25 cm all as specified in srl no 26 of Appendix A | M AND L for Returning filling including spreading leveling watering in layers not exceeding 25 cm all as specified in srl no 26 of Appendix A |
| 27 | M and L for Removing excavated material all as specified in srl no 27 of Appendix A | M and L for Removing excavated material all as specified in srl no 27 of Appendix A |
| 28 | M and L for sand cushioning all as specified in srl no 28 of Appendix A | M and L for sand cushioning all as specified in srl no 28 of Appendix A |
| 29 | M AND Labour for old size sub class B bricks laid in trenches all as specified in srl no 29 of Appendix A | M AND Labour for old size sub class B bricks laid in trenches all as specified in srl no 29 of Appendix A |
| 30 | M AND L for earthing with galvanized steel earth plate size 60cm 60cm 6mm thick all as specified in srl no 30 of Appendix A | M AND L for earthing with galvanized steel earth plate size 60cm 60cm 6mm thick all as specified in srl no 30 of Appendix A |
| 31 | SITC OF LT panel all as specified in srl no 31 of Appendix A | SITC OF LT panel all as specified in srl no 31 of Appendix A |
| 32 | SITC OF Deep Freezer having hard top double door CAP not less than 500 Ltrs all as specified in srl no 32 of Appendix A | SITC OF Deep Freezer having hard top double door CAP not less than 500 Ltrs all as specified in srl no 32 of Appendix A |
| 33 | M AND L for Point wiring with copper conductor cable 2 POINT 5sqmm all as specified in srl no 33 of Appendix A | M AND L for Point wiring with copper conductor cable 2 POINT 5sqmm all as specified in srl no 33 of Appendix A |
| 34 | S AND F Switch socket 6A OBLIQ 16A 5 in 1 flush type with gang box all as specified in srl no 34 of Appendix A | S AND F Switch socket 6A OBLIQ 16A 5 in 1 flush type with gang box all as specified in srl no 34 of Appendix A |
| 35 | SITC OF Inverter Technology Hot AND Cold Split AC of Cap 1 POINT 5 TR all as specified in srl no 35 of Appendix A | SITC OF Inverter Technology Hot AND Cold Split AC of Cap 1 POINT 5 TR all as specified in srl no 35 of Appendix A |
| 36 | S AND F single pole and neutral steel metal enclosure with two pin and earth plug and socket with one single pole MCB of 32 Amps | S AND F single pole and neutral steel metal enclosure with two pin and earth plug and socket with one single pole MCB of 32 Amps |
| 37 | M AND L for AC Sub main wiring WITH 4 SQMM 1 CORE all as specified in srl no 36 of Appendix A | M AND L for AC Sub main wiring WITH 4 SQMM 1 CORE all as specified in srl no 36 of Appendix A |
| 38 | S AND F heavy duty copper pipe HALF INCH dia all as specified in srl no 37 of Appendix A | S AND F heavy duty copper pipe HALF INCH dia all as specified in srl no 37 of Appendix A |
| 39 | S AND F heavy duty copper pipe 1 OBLIQ 4 INCH dia all as specified in srl no 38 of Appendix A | S AND F heavy duty copper pipe 1 OBLIQ 4 INCH dia all as specified in srl no 38 of Appendix A |
| 40 | S AND F PVC drain pipes of suitable size 25 mm | S AND F PVC drain pipes of suitable size 25 mm |
| 41 | SITC OF Inverter Technology Hot AND Cold Split AC of Cap 2 TR all as specified in srl no 39 of Appendix A | SITC OF Inverter Technology Hot AND Cold Split AC of Cap 2 TR all as specified in srl no 39 of Appendix A |
| 42 | M AND L for AC sub main wiring with single core 6 Sqmm all as specified in srl no 40 of Appendix A | M AND L for AC sub main wiring with single core 6 Sqmm all as specified in srl no 40 of Appendix A |
| 43 | S AND F heavy duty copper pipe of size 15mm all as specified in srl no 41 of Appendix A | S AND F heavy duty copper pipe of size 15mm all as specified in srl no 41 of Appendix A |
| 44 | S AND F heavy duty copper pipe of size 10mm all as specified in srl no 42 of Appendix A | S AND F heavy duty copper pipe of size 10mm all as specified in srl no 42 of Appendix A |