| 1 | Material and labour sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominE7:E11al cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to matched and finised with existing surface are included in the rate complete all as specifed and directed. Note:- (i) 2 run of 4.0 Sqmm main cable, one run of 6.0 Sqmm earth wire and one run length of PVC conduit of size 25mm shall be considered as one running length.(ii) The wiring shall be done in proper color coding using Red,Yellow, Blue for phases, Black for neutral and Green for earth. |
| 2 | Supply and fixing of SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. |
| 3 | Supply and fixing of SP MCB 16 Amps ,10 KA, C curve complete all as specified and directed. |
| 4 | Supply , Installation , testing and commissioning of Electric water heater (Geyser) capacity of 25 Ltrs , heating element upto 2 KW , 230 watt , BEE 5 star rated storage type steel/PVC body with Stainless steel with a glass lined (Vitreous emamel) inner tank comprising with heating element , safety valve, thermostate and automatic thermal cutoff, NRV, require all accessories complete and incl suitable 04 Nos rawl plug alongwith Nuts & Bolts for mounting on wall and making functioning complete all as specified and directed. |
| 5 | Supply and laying of galvanised tubing medium grade 15 mm dia ,ISI marked, including all fittings tee, elbow , all complete and fixed to wall /roof /floor /ceiling by help of suitable clamps complete all as specified and as directed.Note:- All Plumbing work inside the bathroom will be concealed on wall / tiles by cutting & chases etc and making good to the disturbed surfaces to match the existing surface complete. |
| 6 | Supply and fixing of Angle valve 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without ettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specifed and directed. |
| 7 | Supply and fixing of Heavy duty Stainless Steel mesh braided exterior type Connection Pipe ISI marked of of 15 mm dia 450/600 mm long suitable for cold & hot water, for water heaters with SS nuts and PVC/rubber sealing washers as per required at site condition complete all as specified and directed |
| 8 | Supply and fixing Bib taps 15 mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without ettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specifed and directed. |
| 9 | M&L for cutting of existing GI pipe of size 25/20 mm dia in position for addition/alteration of Tee of branches conection complete and insert new conection pipe complete incl jointing and necessary aggangement complete all as specifed and directed. |
| 10 | S & F ceiling fans AC single phasew 230/240V of size 1200mm sweep BLDC 5 star rating complete with electrical connection provding three core round flexible copper conducter cable of suitable size complete all as specifed and directed. Please Enable Macros to View BoQ information |