|
| 1 | Hire charges for LED Flood light luminaire ( white or warm white as required )for 90- 150 watt with the standard housing ,pole & mounting accessories with wiring, connection with skilled operator to operate system etc. as and when required. |
| 2 | With suitable pole |
| 3 | for 1st day |
| 4 | For 2nd / 3rd day |
| 5 | from 4th Day onwards |
| 6 | Without suitable pole |
| 7 | for 1st day |
| 8 | For 2nd / 3rd day |
| 9 | from 4th Day onwards |
| 10 | Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day ) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India |
| 11 | Pump Operator, AC Plant Operator, ELV System Operator, Lift Operator, DG set Operator or any other services operator with experience of 3 years in relevant field ) |
| 12 | Technical Helper Having basic Knowledge of E&M Services |
| 13 | Hire charges for Silent type D.G. Set, including change over switch. Control panel, 2 No. Pipe earthing etc. and excluding POL with skilled operator to operate system as and when etc as required. of following capacity: |
| 14 | 62.5 KVA |
| 15 | for 1st day |
| 16 | From 2nd day onwards |
| 17 | 125 KVA |
| 18 | for 1st day |
| 19 | From 2nd day onwards |
| 20 | Hire charges of Main service line for 3 phase connection upto 50 mtr. Length (without any joint) including meter board, panel/distribution Board and supports with skilled operator to operate system as and when etc as required. |
| 21 | Upto 25.0 sq.mm size PVC insulated and Sheathed cable( Aluminium Armoured or Un-armoured as required.) |
| 22 | for 1st week |
| 23 | For 2nd / 3rd day |
| 24 | from 4th Day onwards |
| 25 | above 25.0 sq.mm & upto 95 Sq.mm PVC insulated and Sheathed cable aluminium Armoured or Un-armoured as required.) |
| 26 | for 1st week |
| 27 | For 2nd / 3rd day |
| 28 | from 4th Day onwards |
| 29 | Hire charges for pedestal fan of size 18\\" / ceiling fan of size 48\\"/56\\" sweep including connections etc.with skilled operator to operate system as and when etc as required. |
| 30 | for 1st day |
| 31 | For 2nd / 3rd day |
| 32 | from 4th Day onwards |
| 33 | Supply and filling of POL for DG sets |
| 34 | Hire charges for Mist Fan complete with required connections and operator with skilled operator to operate system as and when etc as required. |
| 35 | for 1st day |
| 36 | For 2nd / 3rd day |
| 37 | from 4th Day onwards |
| 38 | Hire charges for Jumbo polycarbonate/fiber body moveable desert cooler complete with water filling and operator with skilled operator to operate system as and when etc as required. |
| 39 | for 1st day |
| 40 | For 2nd / 3rd day |
| 41 | from 4th Day onwards |
| 42 | Hire charges for following type of Airconditioners including copper piping , drain piping and electrical connections with skilled operator to operate system as and when etc as required. |
| 43 | 3.0 /4.0 TR Tower type split AC |
| 44 | for 1st day |
| 45 | 2nd day onwards |
| 46 | Hire charges for Floor cable protector for laying Temporary cable during events made out from LPDE/PU , Each protector should be with an anti-slip textured top surface for maximum grip, should be easily linked together to create required length of following sizes. |
| 47 | Width 135 - 200 mm x Height 25 mm (or above) |
| 48 | for 1st day |
| 49 | For 2nd / 3rd day |
| 50 | from 4th Day onwards |
| 51 | SITC of following capacity BIS certified 1Phase Input, 1Phase Output advance DSP controlled IGBT based rectifier Online UPS with 0.99 Input power factor &0.8 Output factor, having Input voltage & frequency range of 180-300V on full load/ 110-300V on 60% load & 50 Hz +/- 5% and output voltage & frequency of 230V+/-1% & 50 +/- 0.1 Hz.Overloading of 105 - 110% 10 mins, 111 - 130% 2 mins,131 - 150% 30 sec, THDv of < 3% for Linear & < 5% for Non linear load.UPS should have LCD display showing load level, Battery Voltage Level, Input & Output Voltage, Input & Output Frequency. UPS should have protection from Input High / Low;Over Load;Short Circuit; Over Temperature and give audible alarms on Battery Mode;Low Battery;Fault;Over Load & Bypass Mode.SMF Batteries of 12V VRLA for 30 min back up with MS Rack and necessary cable for UPS to Batteries Installation. UPS should have CE, ROHS, IEC62040-1,2&3 compliance and should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location Etc. as required. |
| 52 | 2KVA UPS with 1872 VAH Battery Please Enable Macros to View BoQ information |