| 1 | (Supply Part) - 230 KVA 22/0.4KV Sub-Station |
| 2 | Prov. Distribution Transformer (Ordinary), 22/0.4 kV, 250 KVA |
| 3 | Prov. Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 4 | Prov. Muffs with concerete filling |
| 5 | Prov. X-Arm: [Channel Iron (100x50x5mm), Length : 2800 mm X 2Nos] |
| 6 | Prov. X-Arm: [Channel Iron (75x40x4.8 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 7 | Prov. MS Angle Iron (50X50x6 mm), Length: 2800 mm x1 Nos for LA's) |
| 8 | Prov. X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for Transformer Bed |
| 9 | Prov. X-Arm [Channel Iron (100x50x5 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer] |
| 10 | Prov. MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 11 | Prov. MS Angle Iron (35X35x6 mm), Length : 460 x 2 Nos |
| 12 | Prov. MS Angle Iron (50X50x6 mm), Length 950 mm x 2 Nos for bed knee bracing |
| 13 | Prov. MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 14 | Prov. MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos |
| 15 | Prov. GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm |
| 16 | Prov. GO AB Switch Unit (22kV, 400A, 25 KA ) |
| 17 | Prov. D.O Fuse Unit |
| 18 | Prov. Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 19 | Prov. Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 20 | Prov. Stay set complete |
| 21 | Prov. Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 22 | Prov. Pipe Earthing Set |
| 23 | Prov. GI wire 6SWG |
| 24 | Prov.LT Distribution Panel Box with CoppPer thimbles of 200 Amp, Insulating sleeves etc. MCCB 400 amp 3P 50kA -1 No. ICS 100 % ICU & MCCB 250 Amp 36 kA =3 nos |
| 25 | Prov. Half Clamp (M.S. Flat 50X6 mm) |
| 26 | Prov. Full Clamps (M.S. Flat 50X6 mm) |
| 27 | Prov. Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 28 | Prov. Aluminium Thimble |
| 29 | Prov. Aluminium Thimble Copper |
| 30 | Prov. Danger Plate |
| 31 | Prov. Barbed Wire |
| 32 | Prov. LT Cable 3.5X400 mm² mm² incommer |
| 33 | Prov. LT Cable 3.5X185 mm²mm2 6 outGoing |
| 34 | Transportation Charges |
| 35 | (Supply Part) of 22 KV H.T. Line |
| 36 | Prov. ACSR 6/1/3.35(50 mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage)} |
| 37 | Prov. Steel Tubular Poles 9 mtr. |
| 38 | Prov. Muffs (2000mm) with concerete filling |
| 39 | Prov. X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] |
| 40 | Prov. MS Angle Iron Knee Bracing (50x50x6 mm), Length: 2 x 750mm Structures |
| 41 | Prov. X-Arm ) - MS Channel Iron: 100x50x5 , Length: 1800 mm |
| 42 | Prov. MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 43 | Prov. GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm |
| 44 | Prov. GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
| 45 | Prov.D.O Fuse Unit |
| 46 | Prov. 22 kv Discs insulator |
| 47 | Prov. 22 kV Pin Insulators |
| 48 | Prov. Pole top Bracket (On single Pole Structure) [ MSCI:100x50x6- 100 mm] |
| 49 | Prov. Stay set complete in all respect( i/c Stay Clamp) (1No. / Single Pole , 4 No. / Double Pole Structures) |
| 50 | Prov. Stay Wire (7/4.00 mm) (10.0 kg Per Stay Set) |
| 51 | Prov. HT Earthing set complete |
| 52 | Prov. Earth wire (GI, 6 SWG) |
| 53 | Prov. Eye Hook for earth wire |
| 54 | Prov. Earth Reel |
| 55 | Prov. Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 56 | Prov. Half clamps: [On Double Pole structure: 6 No, On Single Pole structures: 3 No.] |
| 57 | Prov.Full clamps: [On Double Pole structure: 4 No, On Single Pole strucrures: 2 No.] |
| 58 | Prov. Barbed wire |
| 59 | Prov. Danger Plate (203X200X1.6 mm) |
| 60 | Prov. Red oxide |
| 61 | Prov. Aluminium Paint |
| 62 | Prov. Dell 24 All-in-One|14th i3-100U, 8GB RAM DDR5 512GB SSD,Intel Graphics|23.8\\" FHD AG,IPS, 99% SRGB|Win 11+MSO'24+O365|Molded Speaker Grill| Intel WiFi 6e|5MP Pop-Up IR Camera|Dolby Atmos Dual Speakers-Three years comprehensive onsite warranty |
| 63 | Prov. Numeric 1000VA or higher UPS Offline HRV series:- Capacity in VA-1000 VA -Capacity in Watts -600 Watts Inverter Device-MOSFET, Rated Output Voltage-230 V (1-Phase), Rated Output , UPS is compatible to Li-ion batteries as external bank , but Li-ion batteries cannot be position inside the 1000VA UPS chassis |
| 64 | Prov. HP Mono Chrome Multi-Function Laser Printer HP Laser MFP M1188A printer:- A4 Size Paper, Printing speed 20PPM, Resolution 1200dpi, Memory 128MB, Copy Speed (Mono) 20CPM, Scan Speed Black and Colour 6PPM & 3PPM, USB 2.0, Paper Tray Capacity 150 Pages, With One Year Warranty (except consumable & breakage & Burnt items). |
| 65 | Prov. & Installation of KENT Grand RO Water Purifier | Advanced RO Tech for Sabse Shudh Paani | RO+UF+TDS Control + UV LED Tank | 8L | 20LPH Flow | Ideal for Borewell/Tanker/Municipal Water | Largest Service Network |
| 66 | Prov. Diego Mid-Back Mesh Office Chair | 3 Year Warranty | Ergonomic Study | Computer Chair with Revolving Base | Tilting & Height Adjustable Mechanism | Heavy-Duty Metal Base (Black) (DIY) |
| 67 | Prov. SLEC307 4MP IP BULLET CAMERA 4MP IP BULLET CAMERA (HSN CODE 8525) |
| 68 | Prov. SLEC250 4 PORT POE SWITCH 4 PORT POE SWITCH (HSN CODE 8517) |
| 69 | Prov. SLEC043 4 CH NVR 4 CH NVR (HSN CODE 8521) |
| 70 | Prov. SLEC068 HDD 2TB HDD 2TB (HSN CODE 8471) |
| 71 | Prov. SLEC048 5*5 JUNCTION BOX 5*5 JUNCTION BOX (HSN CODE 8473) |
| 72 | Prov. SLEC054 RJ-45 CONNECTORS RJ-45 CONNECTORS (HSN CODE 8536) |
| 73 | Prov. SLEC160 4U RACK 4U RACK (HSN CODE- 8473) |
| 74 | Prov. SLEC071 LED TV 32\\" LED TV (HSN CODE 8528) |
| 75 | Prov. SLEC159 PVC PIPE PVC CONDUIT PIPE WITH ALL ACCESSORIES (HSN CODE- 3917) |
| 76 | Prov. SLEC007 CAT- 6 LAN CABLE CAT-6 LAN CABLE (HSN CODE 8544) |
| 77 | Transportation charges |
| 78 | (Supply Part) of L T . Line |
| 79 | Prov. Steel Poles,8 Mtr.long |
| 80 | Prov. RCC muff with concrete filling |
| 81 | Prov. AAAC 7/3.81mm |
| 82 | Prov. Shackle Insulator. |
| 83 | Prov. D-iron. |
| 84 | Prov. L T Stay set Complete |
| 85 | Prov. Stay Wire 7/3.15mm @ 6.0 kg per stay set |
| 86 | Prov. G.I. Wire 8 SWG for earth wire + Guarding |
| 87 | Prov. Egg Insulator |
| 88 | Prov. LT Earthing set |
| 89 | Prov. Nuts & Bolts off sizes @ 25 Kg/Km |
| 90 | Prov.Red Oxide |
| 91 | Prov.PVC Specer |
| 92 | Prov.Aluminum paint for steel pole @ 1 Ltr p/pole |
| 93 | Prov.LT Cable (3.5 Core) 185 mm² |
| 94 | Prov. Stay Clamp |
| 95 | Prov.Earth Hook |
| 96 | Prov. Kit Kat 500 Amp |
| 97 | Transportation charges |
| 98 | (SupplyPart ) - H T CT/PT Metering Unit |
| 99 | Prov. CT-PT Combined Unit [PT:22 kV/110 V) ; CT:10-400/5A] |
| 100 | Prov. 3-phase, 3/4-Wire CT-PT operated Static Trivector Meter (DLMS Compliant) |
| 101 | Prov. PVC Multistrand 2.5 mm² copper wire |
| 102 | Prov.1 inch dia GI pipe for concealing |
| 103 | Prov. bend joints/ elbow |
| 104 | Prov. X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] |
| 105 | Prov. X-Arm: [Channel Iron (75x40x4.8 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 106 | Prov. X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of CT-PT Unit] |
| 107 | Prov. MS Angle Iron (50X50x6 mm), Length: 2800 mm x1 Nos for LA's) |
| 108 | Prov. MS Angle Iron (50X50x6 mm), Length : 2800 mm x 2 Nos |
| 109 | Prov. MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos |
| 110 | Prov. MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing |
| 111 | Prov. GO AB Switch Unit (22kV, 400A, 25 KA ) |
| 112 | Prov. D.O Fuse Unit |
| 113 | Prov. Surge Arrester, 18 kV , 10 kA Station Class (Porcelain Type) |
| 114 | Prov. Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 115 | Prov. Stay set complete (i/c Stay Clamp) |
| 116 | Prov. Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 117 | Prov. Pipe Earthing Set |
| 118 | Prov.GI Wire 6 SWG For Earthing |
| 119 | Prov. Half Clamp (M.S. Flat 50X6 mm) |
| 120 | Prov. Full Clamps (M.S. Flat 50X6 mm) |
| 121 | Prov. Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 122 | Prov. Aluminium Thimble |
| 123 | Prov. Copper tinned thimble |
| 124 | Prov. Danger Plate |
| 125 | Prov. Barbed Wire |
| 126 | Prov. Red Oxide |
| 127 | Prov. Aluminium Paint. |
| 128 | Transportation charges |
| 129 | (Erection Part ) - 250KVA 22/0.4KV Sub-Station |
| 130 | Erection of 250 Kva,22/0.4KV Transformer completed in all respect. |
| 131 | Loading Un-laoading of 250 Kva,22/0.4KV Transformer with Hydra completed in all respect. |
| 132 | (Erection Part) ) of 22 KV H.T. Line |
| 133 | Erection of ACSR/AAAC 50 mm² complete in all respect |
| 134 | Erection of GO Switch complete in all respect |
| 135 | Erection Of Earthing set structure complete in all respect |
| 136 | Erection Of single pole structure complete in all respect |
| 137 | Erection Of Single pole to Double pole structure complete in all respect |
| 138 | Erection Of DO Fuse complete in all respect |
| 139 | Erection Of Stay set complete in all respect |
| 140 | Erection Of G.I wire complete in all respect |
| 141 | Manual carriage of material Road head to site 0.500 km complete in all respect |
| 142 | Installation of CCTV Cameras in HPSEBL Complex at Samkhetar & ESD Kataula complete in all respect. |
| 143 | (Erection Part) ) of L TLine |
| 144 | Erection sagging of AAAC Cond 7/3.81mm(80mm2) complete in all respect |
| 145 | Erection of ST pole 9 mtr complete in all respect |
| 146 | Erection of earthing set complete in all respect |
| 147 | Erection of stay set complete in all respect |
| 148 | Erection charges sagging of GI Wire complete in all respect |
| 149 | Manual carriage of LT line material from road head to site of work with avg distance 0.500 km |
| 150 | (Erection Part) ) of HT CT/PT Metering Unit |
| 151 | Erection of CT-PT Combined Unit Complete in all respect |
| 152 | CIVIL PART (DTR foundation & chain link fencing of existing 22/0.4 kV, 250 KVA distribution transformer |
| 153 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 154 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 20 mm nominal size) |
| 155 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete. |
| 156 | Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 157 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) |
| 158 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 159 | (Civil Part)- C/o Chain Link Fencing for 250 KVA 22/0.4KV Sub-Station |
| 160 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 161 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size) |
| 162 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement: 2 coarse sand) : 3 graded stone aggregate 20 mm nominal size) |
| 163 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 164 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm |
| 165 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :125x65x2.12 mm |
| 166 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm |
| 167 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 168 | Supplying, filling, spreading & leveling gravels of approved size in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. |
| 169 | Centering and shuttering including strutting, propping etc. and removal of form for:Retaining walls, return walls, walls (anythickness) including attached pilasters,buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 170 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter Please Enable Macros to View BoQ information |