| Sl. No. | Item Description |
| 1 | Providing and Laying Solid cement concrete block masonry with M-5 Grade in super structure in cement mortar 1:4 (using crushed sand). The rate shall also include anchoring of rebars with concrete surfaces for transiom and mullions wherever required including making the cut out opening in masonary for flush concealing DB/plug point/switch box enclosure .Note:( Reinforcement will be paid under relevant item) |
| 2 | Providing 15 mm thick plastering using Ready mix internal plastering compound for internal faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding, including providing and fixing G.I. chicken mesh in the junctions of concrete & brick work / masonry (including cutting, fixing with nails in position before plastering) complete all as per specifications and as directed at site by the Engineer-in-charge |
| 3 | Providing 20 mm thick plastering using Ready mix external plastering compound for external faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning scaffolding (up to 10 metres height complete) including Providing and fixing G.I. chicken mesh in the junctions of concrete & brick work / masonry (including cutting, fixing with nails in position before plastering) and all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge |
| 4 | Extra for Plastering exterior walls of free standing height more than 10 m from ground / terrace level for every additional height of 3 m or part thereof |
| 5 | Providing 6mm thick plastering using ready mix plaster on cement concrete or Reinforced cement concrete work with white cement based polymer modified self curing mortar of as per direction of Engineer-In-charge. |
| 6 | Providing and applying white cement based wall putty over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including cleaning, scaffolding complete all as directed by the Engineer-in-charge |
| 7 | Providing and Painting with 1st quality acrylic emulsion paint with Two coats on new work and manufacturer and of required shade and colour, including scaffolding, preparation of the surfaces, etc., including a coat of approved cement primer as per manufacturer's specifications and as directed by the Engineer-in-charge. |
| 8 | Providing, painting, finishing walls with two coats of anti-algae, weather proof acrylic smooth emulsion paint with silicon additives on sand face plaster/ plain plaster & concrete surfaces of required shade over new work including a base coat of exterior waterproof cement primer including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge. |
| 9 | Priming Coat:Providing, and applying single coat of exterior penetrating water-based primer composed of acrylic emulsion polymer primer for superior bonding after thorough cleaning of all laitance, loose material, oil, grease, etc. Allow the primer to cure according its technical instructions |
| 10 | Exterior Waterproof Coating:Providing & Apply one coats of Waterproof Coating composed of high quality emulsion polymer, weather durable pigments, properly selected & graded fine fillers, additives & biocides without any dilution Maintain the spreading rate of 4.20 -4.70 Sq.mtr per litre / coat application to achieve about 100-120 microns DFT. Apply second coat of high quality acrylic emulsion polymer of approved make Raincoat Select Top Coat with interval of 6-8 hours without any dilution spreading at rate of 6.0 -6.5 Sq.mtr / per litre / coat to achieve DFT of 60 –70 microns. The material shall have following technical properties: Attains hairline crack bridging up to 2 mm, Elongation of >100 % as per ASTMD 412; Tensile strength 2.50 Mpa per ASTM D 412, Passes Water Resistance as per SS500 standard, Complies to anti carbonation test as per EN 1062 part 6. |
| 11 | Providing and Painting with Epoxy paint (two or more coats) using approved finishing coat at all locations and levels prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer, preparation of surface and etching with 10% commercial Hydrochloric acid wherever necessary and neutralizing the acid etched areas by washing with 5% solution of soda ash neatly and washing with sufficient water after first coat Epoxy based trowelling compound if required, including preparation of the surface by scrapping, applying sand paper, filling the holes, joint, cracks if any , including scaffolding etc complete as per manufacturers Technical Data and as directed at site to achieve 250 micron Dry film thickness (50 Micron Primer coat and 200 micron finishing Coat) (Contractor has to provide Elcometer sampling sheets etc of his cost for testing film thickness) On Concrete / plastered surfaces |
| 12 | Providing and Painting with Epoxy paint (two or more coats) ON WALLS & CEILINGS using approved finishing coat at all locations prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer , preparation of surface and etching with 10% commercial Hydrochloric acid wherever necessary and neutralizing the acid etched areas by washing with 5% solution of soda ash neatly and washing with sufficient water , after first coat Epoxy based trowelling compound if required , including preparation of the surface by scrapping, applying sand paper, filling the holes, joint, cracks if any, including scaffolding , etc complete. All as per manufacturers Technical Data and as directed at site ( Contractor has to provide Elcometer sampling sheets etc at his cost for testing film thickness) On Concrete/plastered surfaces 500 micron total film thickness ( High build epoxy) |
| 13 | Providing and painting two (or) more coats with Epoxy paint on steel surfaces prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer, preparation of surface by cleaning with wire brush and rubbing with sand paper to remove dust, dirt etc, after first coat Epoxy based trowelling compound if required, including preparation of the surface by scrapping, applying sand paper, by cleaning with wire brush and rubbing, making free of rust, dirt etc. filling the holes, joints, cracks if any etc. complete.all as per manufacturers technical data and as directed at site to achieve 200 micron film thickness (50 micron primer coat + 150 micron finishing coat). |
| 14 | Providing and applying two part food grade polyamide cured solvent less epoxy lining in two coats of minimum 400 micron DFT over dry, clean and dust free surafe of water reating structures. This coat shall be applied by airless spray technique or suitable method and as per specifications & drawings. |
| 15 | Providing and fixing Glazed VITRIFIED floor/wall tiles in different sizes conforming to IS 15622 in all colours and shades in Glossy or Matt or satin finish laid over a bed of minimum 20 mm thick bed of cement mortar 1:4 (using Crushed sand) and jointing with grey cement slurry including grouting with the joints with white cement based Tile Grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-chargeUsing Tiles upto size 600 X 600 mm |
| 16 | Providing and laying minimum 25 mm thick uniform shade Kotah stone flooring over 20 mm thick (Average) base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing in minimum three levels to obtain mirror polish complete with base cement mortar 1:4 (using crushed sand) all as per specifications, patterns anddrawings complete. |
| 17 | Providing and Laying Minimum 25 mm thick uniform shade Kotah stone treads and risers of steps, skirting, window sills in single length up to 2.00 metres length slab dado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing toobtain mirror finish complete as per specifications, drawings and as directed by the Engineer-incharge |
| 18 | Extra for nosing in steps of treads Using Kotah stone |
| 19 | Providing and laying (IPS Flooring) cement concrete flooring 1:2:4, using crushed sand 50 mm thick finished smooth to the required level, finishing with a floating coat of neat cement including cement slurry, providing and fixing 25 X 3 mm aluminium / glass strip, curing, cleaning the surface neatly at the time of handing over the area complete as per specifications and drawings as directed by the Engineer in charge |
| 20 | Providing and laying 50 mm thick cement concrete flooring with concrete hardener topping under layer 38 mm thick cement concrete 1:2:4 and top layer 12 mm thick wearing surface with floor hardener, cement being mixed with floor hardener of approved quality and make in the ratio of 4:1 (4 cement and 1 floor hardener) by weight and this cement hardener compound mixed with 6 mm down graded stone aggregate in the ratio of 1:2 by volume includingproviding and fixing 25 X 3 mm aluminium / glass strip, This includes cost of cement slurry, finishing to the required finishing and cleaning neatly while handing over the areas etc. complete as per specifications and drawings. |
| 21 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 of approved make. shade and colour of size ranging from 300 - 600 mm long and 300 mm - 600 mm wide and thickness not less than 6 mm as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints with matching colour Tile grout of matching shade including using PVC tile trim in the exposed corners, complete as per drawings,patterns and specifications complete as directed by the Engineer-in-charge. |
| 22 | Providing and fixing 1st quality ceramic glazed floor tiles of minimum 300 - 600 mm long and 300 - 600 mm wide and thickness not less than 6 mm conforming to IS 15622 of approved make in all colours and shades as approved by Engineer-in-charge over a bed of 20 mm thick bed of cement mortar 1:4 (using crushed sand) and jointing with grey cement slurry including pointing with whitecement based Tile grout of matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge |
| 23 | Providing and fixing 15 mm thick flooring with acid and alkali resistant tiles of approved make and colour as per IS 4457 using acid and / or alkali resistant mortar bedding and joints filled with acid and / or alkali resisting Epoxy for 5 to 8 mm depth over a bed of Bitumastic compound 8 to 10 mm layer and bitumastic primer complete as per the direction of the Engineer-in-charge In flooring over a bed of minimum 10 mm thick acid proof mortar with acid and / or alkali resistant tiles of size 200 X 200 X 15 mm of approved colour including providing required slopes and levels ( this work to be carried out through approved specialized agency) complete as per specifications and as directed by the Engineer-in-charge |
| 24 | Providing and fixing 10 mm thick skirting / Dadooing with acid and alkali resistant tiles of approved make and colour as per IS 4457 using acid and / or alkali resistant mortar bedding and joints filled with acid and / or alkali resisting Epoxy for 5 to 8 mm depth over a bed of Bitumastic compound 8 to 10 mm layer and bitumastic primer complete as per the direction of the Engineerin-charge In flooring over a bed of minimum 10 mm thick acid proof mortar with acid and / or alkali resistant tiles of size 300 X 300 X 10 mm of approved colour including providing required slopes and levels (this work to be carried out through approved specialized agency) complete as per specifications and as directed by the Engineer-in-charge |
| 25 | Providing and fixing Minimum 17 mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut Granite of Telephone Black colour for kitchen platforms, vanity counters, Wash basin Counters, Door Frames, window sills, facias and similar locations of required size, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish etc. complete as directed by the Engineer-in-charge at all levels |
| 26 | Providing and fixing FRP door shutters flush door / panelled type with plain colour or wooden veneer finish of approved make, design & colour. made out of 1.5 mm thick FRP skin moulded over wooden frame work of 40 mm wide and required thickness wooden styles and minimum 100 mm wide lock rails and wooden blocks for door stoppers, tower bolts, baby latch, aldrop, handles etc. wherever required and core filled with Polyurethane Foam and fixing with 4 Nos 100 mm (ISI marked) stainless steel hinges with S.S. wood screws 35 mm thick panelled door type of approved colours including the cost of 100 mm ISI marked heavy quality stainless steel butt hinges with necessary screws. |
| 27 | Providing, supplying and fixing hollow metal flush steel doors 40 mm thick of approved make consisting of door frame and shutters and all hardware fittings, frame made out of 14g thick G.I sheets and shutters made of 16g thick sheets, hollow portion filled with puff / concrete, including necessary stiffeners in shutters and frame, vision panel of specified size with 4 mm glass and clip onpressed steel frame for vision panels, fixing 4 nos heavy duty stainless steel 304 grade ball bearing, fire tested stainless steel butt hinges of size 100 x 75 x 3.00 mm (heavy weight) of approved make with suitable stainless steel screws, mortise / dead lock of approved make, a pair of 200 mm long stainless steel handles, 250 mm long stainless steel tower bolt, etc. frame hollow portion filled with PCC 1:2:4, necessary hold fast embedded in concrete, fixing in concretewith anchor fasteners. finished with Polyurethane painting of approved colour complete all as per drawings and specifications and as directed by the Engineer-in-charge |
| 28 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg , with double speed adjustment with necessary accessories and screws etc. complete. |
| 29 | Providing and fixing factory made Single / Double leaf Partially insulated metal fire rated door set of FD 120 Pl classification with 120 minutes integrity and 30 minutes insulation as per lS 3614:2021 consisting of galvanized iron steel frame and Single / Double leaf shutter including necessary hardware accessories, conforming to FD 120 Pl classification of lS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick Gl Sheet with minimum 120 GSM Zinc coating as per lS: 277. The entire fire rated door set assembly shall be tested in latched condition as per lS 17518 (Part -l) 2022. The recommended fire doors shall have type test report from NABL certified lab. Proper label confirming the type of door and the hourly rating shall be mandatory. Frame: The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self-tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per lS 4351. The smoke seal material shall be of EPDM tested in accordance with ASTM E-84 of minimum size 10x 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonry/concrete wall opening with CSK/Hex/Any other headed fastener of minimum 8 mm dia size and minimum 80mm long with 8mm dia Polyamide sleeves @ 5 numbers at each on vertical sides and 2 numbers on horizontal top side. Door shutter: The double skinned single leaf partially insulated fire rated door shutters shall be consisting of minimum 50 mm thick and having box like structure, slots cut and holes punched, for fixing of hardware’s with stiffeners as per lS: 16074 including resin bonded mineral wool / ceramic wool infill material of minimum density 96 kg/cum. Door leaf shall be provided with vision panel, having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size l3x2 mm to be fixed all around the glass on both the sides/ as per manufacturer arrangement. The intumescent seal of minimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaf. The door shutter shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935:2002 or butt hinges as per lS 12817, of minimum size 100x75x3 mm @ 5 numbers hinges up to 2400mm height or as per test evidence, whichever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories. Hardware Accessories: Mortise / dead lock, a pair of 200 mm long stainless steel handles, 250 mm long stainless steel tower bolt / concealed tower bolt etc. One/Two (Single/Double leaf) number heavy duty door closer of size EN 3-5 with standard arm, of desired finish (suitable up to 1250 mm door width) conforming to lS 3564/EN 1154. Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per lS:13871 of approved colour and shade all complete as per manufacturer specifications and as per direction of the Engineer-in-charge. Installation: The hollow space in the door frame shall be filled with PCC 1:2:4/ cement grout after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer. Complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 30 | Providing and fixing fire rated Steel Rim Panic Exit Device of approved brand & quality in single leaf door upto 1000mm wide including all accessories etc. complete. |
| 31 | Providing and fixing anodized aluminium work for doors, windows, Louvers, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealant etc. (fittings glazing and panelling shall be paid for separately) Anodised Aluminium sections (Minimum anodizing thickness of 15 micron) |
| 32 | Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item) With tinted toughened float glass panes of 6.00 mm thickness |
| 33 | Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item) With clear float glass panes of 6.0 mm thickness |
| 34 | Providing and fixing 6 mm thick e-board in panelling, masking, fixed in aluminium doors, windows, shutters and partition frames with C.P Brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge |
| 35 | Providing and fixing stainless steel aldrops of size 300 X 14 mm of approved make withnecessary screws, bolting from rear side complete as per specifications complete. |
| 36 | Providing and fixing 4 Lever Mortice Lock of approved make suitable for aluminium sections |
| 37 | Providing and fixing pair of stainless steel \\"C\\" type door handles 10 mm dia, 250 mm long SS304 grade solid rod , of specified size in steel doors/ wooden doors including screws / bolts etc.all as per drawings and specifications complete |
| 38 | Supplying and fixing Rolling shutters of approved make as per ISI standards made out ofrequired size of MS/GI lathes 18 gauge interlocked together throughout entire length and jointedtogether at the end by end locks mounted on specially designed pipes shaft with brackets, sideguides and arrangements for inside & outside locking with push and pull operation completeincluding the cost of providing and fixing necessary springs of required size and M. S top cover ofrequired thickness for rolling shuttersRolling shutters (Laths Interlocked) gear operated type with handles including top hood 1.25mmmm thick |
| 39 | Extra over the cost of rolling shutters for providing and fixing motorized arrangements( withremote & manual operation) including designing, control panels, limit switches, required wiringand cables from panel to motor and required size of shaft etc of approved make all as perstandard specifications including commissioning and testing complete as directed by theEngineer-in-charge.(only power supply point will be provided)For rolling shutters above up to 60 sq.m opening area. |
| 40 | Providing , Laying , jointing, fixing and testing Heavy quality (C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing Teflon tape, exposed / concealed by chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint for all concealed lines / two coats of synthetic enamel paint for all exposed lines all as directed by the Engineer-in-charge. 15 mm dia G.I pipe |
| 41 | Providing , Laying , jointing, fixing and testing Heavy quality (C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing Teflon tape, exposed / concealed by chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint for all concealed lines / two coats of synthetic enamel paint for all exposed lines all as directed by the Engineer-in-charge. 20 mm dia GI pipe |
| 42 | Providing , Laying , jointing, fixing and testing Heavy quality (C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing Teflon tape, exposed / concealed by chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint for all concealed lines / two coats of synthetic enamel paint for all exposed lines all as directed by the Engineer-in-charge. 25 mm dia GI pipe |
| 43 | Providing , Laying , jointing, fixing and testing Heavy quality (C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing Teflon tape, exposed / concealed by chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint for all concealed lines / two coats of synthetic enamel paint for all exposed lines all as directed by the Engineer-in-charge. 32 mm dia GI pipe |
| 44 | Providing , Laying , jointing, fixing and testing Heavy quality (C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing Teflon tape, exposed / concealed by chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint for all concealed lines / two coats of synthetic enamel paint for all exposed lines all as directed by the Engineer-in-charge. 40 mm dia GI pipe |
| 45 | Providing , Laying , jointing, fixing and testing Heavy quality (C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing Teflon tape, exposed / concealed by chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint for all concealed lines / two coats of synthetic enamel paint for all exposed lines all as directed by the Engineer-in-charge. 50 mm dia GI pipe |
| 46 | Providing and fixing C.P brass bib cock of heavy quality of specified / approved make as per specifications and as directed by the Engineer-in-charge. 15 mm dia bib cock of approved type and make . |
| 47 | Providing and fixing 15 mm C.P brass 2 in 1 bib cock and Angle cock combinat ion of Heavy Quality of approved make as per specifications and as directe d by the Engineer-in-charge |
| 48 | Providing and fixing C.P brass concealed stop cock of Heavy Quality of specified / approved make as per specifications and as directed by the Engineer-in-charge. |
| 49 | Providing and fixing C.P brass Angle cock of heavy quality of specified, for wash basin inlet / flush cistern etc. as per specifications and as directed by the Engineer-in-charge 15 mm n.b CP brass Angle cock. |
| 50 | Providing and fixing Heavy Quality 15 mm C.P brass san neck pillar cock of approved make as per specifications and as directed by the Engineer-in-charge. |
| 51 | Providing and Fixing CP brass 100 mm dia shower rose with Shower arm as per specifications and as directed by Engineer-in-charge complete |
| 52 | Providing and fixing heavy quality health faucet with 1.50 metres long flexible hose (hand shower) of approved make with wall brackets and type as per specifications and as directed by the Engineer-in-charge |
| 53 | Providing and fixing square mouth S.W. gully trap complete with CI grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg as per standard design. 150 x 100 mm size gully trap \\"P\\" type. |
| 54 | Providing and fixing cast iron nahani trap / floor trap of 100 mm inlet and 75 mm outlet, (weighing 5.80 Kg each), jointing with lead with the connection pipes, placing as per the drawings, embedding in cement concrete 1:2: 4 and making circular hole up to floor level using 110 mm O/D PVC pipes of 6 Kg / sq.cm pressure and fixing 1 No 125 mm dia C. P brass grating , complete all as specifications and drawings and as directed by the Engineer-in-charge |
| 55 | Providing and fixing Heavy quality flexible PVC waste pipe of 32 mm dia flexible (semi-rigid) for sink or wash basin including PVC waste fittings etc. complete all as per specifications and as directed by the Engineer-in-charge |
| 56 | Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels of approved make including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by the Engineer-in-charge. 40 mm n.b |
| 57 | Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels of approved make including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by the Engineer-in-charge. 50 mm n.b |
| 58 | Providing, supplying, fixing in position, under floors or in walls centrifugally cast iron pipesincluding required specials like bends, tees, 'Y' collars, cowl etc for soil, waste and ventilationpipes conforming to IS.3989 of approved make including cost of jointing with spun yarn andmolten lead of specified quantity, caulking the joints, including testing of pipes, painting withprimer, fixing at walls with necessary approved type of clamps and brackets complete all as perdrawings and specifications and as directed at site.75 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 0.90 kg lead / joint |
| 59 | Providing, supplying, fixing in position, under floors or in walls centrifugally cast iron pipesincluding required specials like bends, tees, 'Y' collars, cowl etc for soil, waste and ventilationpipes conforming to IS.3989 of approved make including cost of jointing with spun yarn andmolten lead of specified quantity, caulking the joints, including testing of pipes, painting withprimer, fixing at walls with necessary approved type of clamps and brackets complete all as perdrawings and specifications and as directed at site.100 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 1.00 kg lead / joint |
| 60 | Providing, supplying, fixing in position, under floors or in walls centrifugally cast iron pipesincluding required specials like bends, tees, 'Y' collars, cowl etc for soil, waste and ventilationpipes conforming to IS.3989 of approved make including cost of jointing with spun yarn andmolten lead of specified quantity, caulking the joints, including testing of pipes, painting withprimer, fixing at walls with necessary approved type of clamps and brackets complete all as perdrawings and specifications and as directed at site.150 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 1.20 kg lead / joint |
| 61 | Providing and fixing terminal guards (slotted C.I cowls) for the following Dia of C.I Pipes asdirected by the Engineer-in-charge100 mm Dia C.I cowl |
| 62 | Providing and fixing terminal guards (slotted C.I cowls) for the following Dia of C.I Pipes asdirected by the Engineer-in-charge150 mm Dia C.I cowl |
| 63 | Providing and laying non pressure NP2 class RCC Hume pipes of approved make, with collars jointed with stiff mixture of cement mortar in the proportion of 1:2, laying to the levels, slopes and as per the drawings and specifications and as directed by the Engineer-in-charge including testing of joints etc. complete250 mm Dia RCC Hume pipe class Np2 |
| 64 | Supplying and fixing Cast Iron Man hole or Cast Iron Steps or CI cover and weight as specified in the drawings or as directed by the Engineer in charge |
| 65 | Providing and laying in position with 150 mm thick hard murum bedding RCC hume pipe septic tank ~1800 mm diameter x 2.5 m length, excluding excavation but inclusive of placing in position, commissioning etc. complete with all pipes vents etc. with connections on both sides. |
| 66 | Constructing soak pit 1.2 * 1.2 *1.2 m filed with brick bats including S.W. drain pipe 100 mm diameter and 1.2 m long complete as per standard design |
| 67 | Providing, supplying, fixing in position in walls Rain water down take pipes using Centrifugally cast iron pipes (3.00 metres long) including required specials like bends, shoes etc for Rain water down take pipes Confirming to IS.3989 of approved make including cost of Jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer , fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site. 100 mm C.I rain water down take pipe with 1.00 kg lead / joint conforming to relevant IS |
| 68 | Providing, supplying, fixing in position in walls Rain water down take pipes using Centrifugally cast iron pipes (3.00 metres long) including required specials like bends, shoes etc for Rain water down take pipes Confirming to IS.3989 of approved make including cost of Jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer , fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site. 150 mm C.I . rainwater down take pipe with 1.20 Kg lead per joint (pipe as per IS 3989) |
| 69 | Providing and fixing white vitreous china European type Water Closet with 'P' or 'S' Trap with solid seat and lid of approved make, 10 litre low level white PVC flushing cistern with manually controlled device (handle lever) conforming to IS:7231, flush bend, fixing EWC with C.P brass screws, 15 mm PVC heavy quality inlet connection of 450 mm long, including testing , commissioning & cleaning etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. E.W.C. pan in White colour with ISI marked white solid plastic seat and lid. |
| 70 | Providing and fixing white vitreous (Single half stall urinal with C.P brass Flush valve). china flat back half stall urinal size 580 x 380 x350 mm / 610 mm, 32mm C.P flush valve with standard flush pipe and C.P. brass spreaders, 32mm urinal waste coupling with dome grating and clamp etc. including making G.I water line connection complete as directed by the Engineer-incharge (Only G.I. pipes will be paid under relevant Item ). |
| 71 | Providing and fixing vitreous China wash basin of approved make and colour with C.I. brackets, 15 m C.P. brass pillar tap of approved make,15 mm x 600mm long PVC Inlet connection, 32 mm heavy quality C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge. White vitreous China wash basin size 630 x450 mm and equivalent sizes with single 15 mm C.P. brass pillar tap |
| 72 | Providing and fixing vitreous China wash basin of approved make and colour with C.I. brackets,15 m C.P. brass pillar tap of approved make,15 mm x 600mm long PVC Inlet connection, 32 mmheavy quality C.P. brass waste coupling of standard pattern, including painting of fittings andbrackets, cutting and making good the walls and testing complete all as per specifications and asdirected by the Engineer-in-chargeWhite vitreous China counter top / counter below wash basin size 560 x 410 mm / 560 x 450 mmwith single 15 mm C.P. brass pillar tap (OVAL / ROUND Models |
| 73 | Providing and fixing 6 mm thick mirrors of size 600 x 450 mm of approved make with bevelled edges complete with 6 mm thick asbestos sheet back ground fixed to walls with C.P. brass screws and concealed washers complete. all as per specifications and as directed by the Engineer-in-charge . |
| 74 | Providing and fixing 150 X150 mm soap dish of white vitreous Chinaware, of approved make including chasing walls making good the same after fixing the China Soap dish etc. complete all as per specifications and as directed by the Engineer-in-charge |
| 75 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 76 | Providing and Laying cement concrete 1:2:4 in super structure (1 cement, 2 crushed sand, 4 brickaggregates 20 mm to 40 mm) for filling sunken floors of toilet bath & kitchen admixed withproprietary water proofing compound as per manufacturer's specifications and approved byEngineer-in-charge including scaffolding, consolidation, finishing curing etc |
| 77 | Providing and laying water proofing treatment in sunken portions of WCs, bath rooms etc. by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) 1st layer of slurry of cement @ 0.488 kg / sq.m mixed with water proofing cement compound @ 0.253 kg per sq.m. including injecting cement slurry .This layer will be allowed to air cure for 4 hours.(b) 2nd layer of slurry of cement @ 0.242 kg / sq.m mixed with water proofing cement compound@ 0.126 kg / sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners,junctions of pipes and masonry with cement slurry. Finishing the surface with 20 mm thickjointless cement mortar of mix 1:4 (using crushed sand) admixed with proprietary water proofingcompound conforming to relevant IS and approved by Engineer-in-charge including mixingpolypropylene fibre at the rate of 125 grams per 50 kg of cement in top layer of plaster and finallyfinishing the surface with trowel with neat cement slurry in bottom and all the sides of sunkenportion. complete as directed by the Engineer-in-charge. The treatment to be tested for watertightness before filling the sunken areas |
| 78 | Laying brick bats with mortar using broken brick bats 25 mm to 115 mm size with 50% ofcement mortar 1:4 (using crushed sand) admixed with proprietary water proofing compound asper manufacturer's specifications conforming to relevant IS and approved by Engineer-in-chargeover 20 mm thick layer of C.M 1:4 (using crushed sand) to required slope complete as directed bythe Engineer-in-charge. |
| 79 | Providing cement based water proofing treatment to the new terraces, chajjas, cleaning theconcrete surfaces, giving injections to the top slab as required with cement and approvedwaterproofing compound solution to fill up all inherent holes, voids, honeycombs etc. in theconcrete slab, setting brickbat coba in waterproof mortar with necessary gradient for easy flow ofwater and continue the treatment along the inner faces of parapet or other adjoining wall up to aheight of 300 mm in thew shape of vattas, with waterproof plaster finished smooth with trowel incement / geru with false markings of 300 mm squares complete as directed by the Engineer-inchargeWith Average thickness of 120 mm and minimum thickness at khurra as 65 mm using river sand /crushed sand |
| 80 | Earth work excavation by mechanical means (Hydraulic excavator) / manual means in all types ofsoil other than soft and hard rock, dressing the sides of foundation, ramming of bottom etc.including shoring and dewatering (if necessary) and refilling with selected excavated earth inlayers of not more than 500 mm thick, each layer well rammed and consolidated includingdisposing the surplus earth within a distance of 200 m all as per specifications including clearingJungle, uprooting of vegetation, grass, etc. complete and as directed by the Engineer-in-charge.From 0 to 2 m depth from average ground level |
| 81 | Lead charges for lead exceeding 2 KM but not exceeding 3 KM, by mechanical transport includingloading, unloading, stacking / levelling etc. |
| 82 | Supplying, stacking and laying of 230 mm thick rubble soling stones as under floor base including packing with smaller stone and compacting, ramming including spreading and consolidation of blinding material, moorum etc. complete all as per specifications and as directed by the Engineer-in-charge230mm With outside material |
| 83 | Murum filling under floors of specified thicknessin layers of not exceeding 150 mm thickness including consolidation etc. complete (using murrum available at site)Note: a) Only compacted volume will be measured and paid, b) Selected / approved excavated stuff stored within the DAE premises shall be issued free of cost to the contractor for filling purposes. |
| 84 | Providing and laying in position cement concrete of 1:2:4 (1 cement, 2 crushed sand, 4 gradedstone aggregate of nominal size 20 mm) including consolidation, finishing, curing etc. complete asper specification and drawings but excluding the cost of Formwork shuttering, centering andsteel reinforcement at all Levels |
| 85 | Providing and fixing at all levels precast members using cement concrete of Grade M-30 in Cell Plugs (upto 30 m height from ground), copings and / or bed blocks, plain window sills, shelves, louvers, steps, staircases, etc. including transporting, lifting, hoisting, placing and setting in position with C.M 1:3 (using crushed sand) or as directed, cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (using crushed sand) on exposed surfaces complete as per specifications and as directed by the Engineer-in-charge |
| 86 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. at all levels complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications. |
| 87 | Extra over above item 6 and item 7 for precast/RCC members using cement concrete of Grade M-60 |
| 88 | Providing and laying in position cement concrete (RCC or PCC) of 1:1.5:3 at all levels (1 cement, 1.5 crushed sand, 3 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curing etc. complete as per specifications and drawings but excluding the cost of shuttering, centering and steel reinforcement. |
| 89 | Providing, centering, shuttering Form work using steel plates, timber planks for all types of structures at all levels including necessary strutting, proping, staging, supports, bracings etc. and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels |
| 90 | Providing and fixing TMT Steel Reinforcement bars of specified grades manufactured using virgin materials confirming to IS 1786 for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings. Using TMT bars of specified grades. |
| 91 | Providing Structural steel work in M.S Plain Plates and chequered Plates and other sections, for Embedded Parts, structural steel floors, frame works, monorails and other structuresTrench Covers, Connection plates etc. Including cutting, hoisting, fixing in position and applying a priming coat of approved zinc chromate steel primer etc. Including cost of structural steel Plates, welding all labour charges etc. complete as per drawings and specifications. Using materials produced by vendors as per Approved Vendor list of BARC using virgin materials. |
| 92 | Providing and fixing hand rail of approved size and shape by welding etc. to steel ladder railing, balconyrailing & staircases railing including applying a priming coat of zinc chromate steel primer etc.complete as per specifications using M.S tubes of ISI marked (Medium) of specified diameter andthickness |
| 93 | Providing and fixing hand rail using 304 grade Stainless Steel pipes of approved size and makeand quality by welding, mirror / matt polishing, fixing at site etc. for balcony railing & staircasesrailing including special sections as per drawings, specifications. complete as directed by theEngineer-in-charge |
| 94 | Dismantling of RCC works carefully manually without damaging adjacent structures excluding cutting of reinforcement including stacking of steel reinforcement bars and disposal of unserviceable materials within 200 m lead as per direction of Engineer-in-charge |
| 95 | Extra for cutting of reinforcement in RCC, stacking the same and returning the steel scrap to the departmental stores all as per direction of Engineer-in-charge |
| 96 | Making the opening in existing brick masonry for door / window / clear story opening carefully/Dismantling brick/block work in Cement mortar without damaging adjacent structures complete to match existing surface including stacking of materials and disposal of unserviceable materials as per direction ofEngineer-in-charge. |
| 97 | Providing and inserting 12 mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20 mm to 30 mm) up to depth from 30 mm to 80 mm at required spacing and making the hole and cracks dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge. |
| 98 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-inCharge. (The payment shall be made on the basis of actual weight of approved grout injected.)Epoxy injection grout in concrete/RCC work of approved make |
| 99 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. |
| 100 | Providing U3 finish for RCC Surfaces rendering smooth top of the suspended floors ,landings and staircases (treads and risers), walls, slab soffits etc. including grinding / carborandum stone for repairing surface defects in areas where forms are removed, ridges at form joints, honey-combed areas, damage resulting from the stripping of forms and bolt holes including chipping / tooling of bulges and ridges, rubbing, cleaning, necessary scaffolding / staging etc. with C.M 1:2 (using Crushed sand) including a floating coat of neat cement and protecting the surface subsequent to cleaning all as per specifications and as directed by the Engineer-in-charge at all levels |
| 101 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8 mm dia. G.l plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufacturedout of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified (2 mm thick flat) |
| 102 | Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints upto 300 mm with an overlap of 50mm on either side |
| 103 | Note for Item No. 104 to Item No. 109 below:Designing, supplying and installing proprietary separation / expansion / seismic joints in RCC framed structure including columns, beams, slab, roof, pavements, walls, floors or any other location comprising of the following as per detailed specification, warranty and as directed by Engineer.The joint cover assembly system comprises of:(i) Elastomeric joint system : shall be made of extruded polyvinyl chloride or approved equivalent material with shore \\"A\\" hardness of 55+5 with UV stabiliser including provision of multi-cellular profile able to transfer loads to adjacent aluminium extrusions. The profile shall be flexible and exhibit a non-slip exposed surface that remains flat during all phases of movement (ii) Aluminium frame members : shall be made out of extruded aluminium sections conforming to ASTM B221. The alloy shall be 6061-T6 or 6063-T5 or H1200 or approved equivalent. The exposed surface shall be mill finished. (iii) Cover Plates, (iv) Self centering / turn bar arrangement : shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions so as to accommodate multi-directional seismic movement without causing stress to joint components. The centre plate shall remain flush during thermal movement and during seismic movement, the centre plate shall displace temporarily and slide over the floor. (v) Sealants : shall be a one part polysulphide base synthetic rubber / silicon sealant. The item shall include for providing secondary seal /visual seal /functional vinyl seal, lubricant adhesive as required at the back for full seismic movement for specific structural gap, fixing to RCC frame work / MS structures / Masonry walls using approved anchor fasteners /sealants on either side of seismic / separation joint. The entire system shall be fully gasketed to eliminate transition rattle, including providing & applying silicone sealant between the joint and abutting the substrate, grouting, scaffolding / staging for all heights, leads & levels etc. all complete as per approved shop drawings, manufacturer's specifications and as directed by the Engineer. The item shall include for repairing & profiling of the existing joint line with the help of approved polymer modified mortar to be fixed in alignment and straight line as per joint design width and joint design complete. The item shall also include for providing and fixing of 1.2mm thick EPDM / PVC water barrier membrane over the joint profile with the help of special adhesive and necessary loop throughout the joint profile before fixing of the joint system to ensure water tight joints etc. complete |
| 104 | Designing, supplying and installing proprietary horizontal floor to floor expansion / separation/ seismic joint cover assembly system of approved manufacturer.WIth Stainless Steel Cover Plate : shall be made out of not less than 5 mm thick stainless steelplate conforming to SS 304 Grade. The plate shall be secured to base members by approvedself centering arrangement. The exposed surface shall be mill finished. (Refer Note in 103 above).for 150 mm wide joints |
| 105 | Designing, supplying and installing proprietary horizontal floor to floor expansion / separation/ seismic joint cover assembly system of approved manufacturer.WIth Stainless Steel Cover Plate : shall be made out of not less than 5 mm thick stainless steelplate conforming to SS 304 Grade. The plate shall be secured to base members by approvedself centering arrangement. The exposed surface shall be mill finished. (Refer Note in 103 above).for 250 mm wide joints |
| 106 | Designing, supplying and installing horizontal floor to wall expansion / separation / seismicjoint cover assembly system of approved manufacturer & comprising ofWIth Stainless Steel Cover Plate : shall be made out of not less than 2 mm thick stainless steelplate conforming to SS 304 Grade. The plate shall be secured to base members by approvedself centering arrangement. The exposed surface shall be mill finished. (Refer Note in 103 above)150 mm wide joints |
| 107 | Designing, supplying and installing horizontal floor to wall expansion / separation / seismicjoint cover assembly system of approved manufacturer & comprising ofWIth Stainless Steel Cover Plate : shall be made out of not less than 2 mm thick stainless steelplate conforming to SS 304 Grade. The plate shall be secured to base members by approvedself centering arrangement. The exposed surface shall be mill finished. (Refer Note in 103 above)250 mm wide joints |
| 108 | Designing, supplying and installing vertical wall to wall expansion / separation / seismic jointcover assembly system of approved manufacturer & comprising ofWith Stainless Steel Cover Plate : shall be made out of 1.6 mm thick stainless steel plateconforming to SS 304 Grade. The plate shall be secured to base members by approved selfcentering arrangement. The exposed surface shall be mill finished. (Refer Note in 103 above)for 150 mm wide joints |
| 109 | Designing, supplying and installing vertical wall to wall expansion / separation / seismic jointcover assembly system of approved manufacturer & comprising ofWith Stainless Steel Cover Plate : shall be made out of 1.6 mm thick stainless steel plateconforming to SS 304 Grade. The plate shall be secured to base members by approved selfcentering arrangement. The exposed surface shall be mill finished. (Refer Note in item 103 above)for 250 mm wide joints |
| 110 | Supply and erection of GI enclosure fabricated out of 1.6mm thick pre galvanised GI sheet steel with required cutting, welding, bending, stiffners as per drawings and embed in concrete or brick wall, cutting brick wall to suit size, etc as required under the instruction of Engineer-In-Charge. (Note: For Item 111 and 112 below) |
| 111 | Supply of enclosure |
| 112 | Installation of enclosure |
| 113 | Supply and Embedment of 25 mm 16 SWG black enamaled heavy duty rigid mild steel (MS) ERW conduit pipe of following sizes along with all accessories such as bends, junction box-1 way, 2 way,3 way,4 way with min 75 mm depth, coupler, socket, check nut, GI fishwire etc. including making threads, removing burrs, connection of accessories, drawing of fish wire, laying in RCC beam and wall, cutting & Laying in brick wall etc. as required under the instruction of Engineer-in-charge. |
| 114 | Supply and Embedment of 40 mm 16 SWG black enamaled heavy duty rigid mild steel (MS) ERW conduit pipe of following sizes along with all accessories such as bends, junction box-1 way, 2 way,3 way,4 way with min 75 mm depth, coupler, socket, check nut, GI fishwire etc. including making threads, chasing on wall, removing burrs, connection of accessories, drawing of fish wire, laying in RCC beam and wall, cutting & Laying in brick wall etc. as required under the instruction of Engineer-in-charge. |
| 115 | Supply of ETP grade 14 SWG annealed tinned solid copper conductor as per alongwith copper clip IS 8130 and tender technical specifications. |
| 116 | Laying of 14 SWG tinned solid copper conductor throughout along the conduit including fixing with copper clip at every 600mm for mounting on 25mm conduit, brazing of conductor etc as required. |
| 117 | Supply and embedment of copper earth plate/ pad of size 40mm wide x 6mm thick x 550 mm long having 10nos. Of 10mm dia tapped hole for outgoing connections and 11mm dia rod on back side for brazing of 2nos. 95 Sq.mm copper conductor including brazing, connection with suitable hardwares such as brass bolt, mounting arrangement etc. The pad shall be brazed with 2nos. 95 Sq.mm copper conductor connection with suitable hardwares etc. as required |
| 118 | Supply and installation in masonary wall of 50 mm dia Medium Class C G.I. Pipe conforming to IS 1239 (Part-1) with threaded ends and socket. |
| 119 | Supply and installation in masonary wall of 100 mm dia Medium Class C G.I. Pipe conforming to IS 1239 (Part-1) with threaded ends and socket. |
| 120 | Electrification Quantity (item no. 121 to 263 below) |
| 121 | Supply of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. (Note: For Item 122 to 128 below) |
| 122 | Supply of 8 way MCB DB having 1 no. main incomer of 16A TPN MCB, Isc=10kA, Type C with 3 nos. of 16A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 123 | Supply of 8 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 124 | Supply of 6 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 125 | Supply of 6 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 126 | Supply of 4 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 127 | Supply of 6 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 128 | Supply of 4 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 129 | Installation, Testing and Commissioning of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. (Note: For Item 130 to 136 below) |
| 130 | Installation, Testing and Commissioning of 8 way MCB DB having 1 no. main incomer of 16A TPN MCB, Isc=10kA, Type C with 3 nos. of 16A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 6A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 131 | Installation, Testing and Commissioning of 8 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 24 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 132 | Installation, Testing and Commissioning of 6 way MCB DB having 1 no. main incomer of 40A TPN MCB, Isc=10kA, Type C with 3 nos. 40A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 133 | Installation, Testing and Commissioning of 6 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 18 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 134 | Installation, Testing and Commissioning of 4 way MCB DB having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 3 nos. 25A, Isc=10kA, DP, RCBO(100mA) as incomer for each phase and 12 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type \\"C\\" curve, 10 kA breaking capacity and as per tender technical specifications. |
| 135 | Installation, Testing and Commissioning of 6 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 136 | Installation, Testing and Commissioning of 4 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 137 | Supply of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. (Note: For Item 138 to 142 below) |
| 138 | Supply of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 12 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 139 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 140 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 6 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 141 | Supply of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 142 | Supply of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 8 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 143 | Installation, Testing and Commissioning of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. (Note: For Item 144 to 148 below) |
| 144 | Installation, testing & Commissioning of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 12 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 145 | Installation, testing & Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 146 | Installation, testing & Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 6 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 147 | Installation, testing & Commissioning of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 148 | Installation, testing & Commissioning of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 8 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 149 | Supply of following LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, PVC conduit bushes, Cu cable lugs as per tender specification. (Note: For Item 150 to 161 below) |
| 150 | Supply of 4ft LED Tube light fixture with 2x14W LED tube with a nominal system lumen output of 4200lm, min 150lm/W efficacy, CCT 6500K and CRI>80, THD<15%, PF>0.9, 4ft LED tube. The luminaire shall meet IP20 rating, SDCM< 7 and RoHS compliant. The fixture shall have single piece construction made of white powder coated CRCA sheet steel suitable for above LED tube light. The LED shall be mounted on extruded aluminium strip which acts as heat sink and is integral part of tube which is made up of extruded poly-carbonate material which gives diffuses light. The total power consumption should not exceed 28W (including driver). |
| 151 | Supply of LED Recessed 2ft x 2ft Luminaire with a nominal system lumen output of at least 4200 lumens and a minimum system efficacy of 120lm/W. The luminaire should have a CCT of 6500K, CRI>80, UGR<22% and SDCM<=5. The luminaire shall meet IP20 rating with THD<10% and PF>0.95. The luminaire housing should made of powder coated metallic CRCA with high effeciency PMMA diffuser. The total power consumption should not exceed 35W (including driver). |
| 152 | Supply of LED Circular Recessed downlighter with a nominal system lumen output of 1500lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95. The luminaire housing should made of polycarbonate with high effeciency diffuser. The total power consumption should not exceed 14W (including driver). |
| 153 | Supply of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 154 | Supply of LED integral driver Flood light with a nominal system lumen output of 8400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 70W (including driver). |
| 155 | Supply of LED integral driver Flood light with a nominal system lumen output of 18000 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 150W (including driver). |
| 156 | Supply of 2 x 36W, 240V, 50Hz, FTL flame proof industrial luminaire suitable for wall mounting complete with heat resistant glass cover, low loss copper ballast, capacitor, lamp, 2nos cable entry nipple, wiring etc. |
| 157 | Supply of LED integral driver Flood light with a nominal system lumen output of 4200 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 6500K and a CRI>70. The luminaire shall meet IP65 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 35W (including driver). |
| 158 | Supply of 4ft Functional Batten (approx dim.140mm x 105mm x 1219mm)with 40W LED Tubelight (acid & corrossion proof) with a nominal system lumen output of 4800 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95. The luminaire housing should made of • Body - glass reinforced polyester (GRP), RAL 7035 • Gasket - polyurethane • Diffuser - UV stabilised prismatic acrylic material. The total power consumption should not exceed 40W(including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 159 | Supply of LED wellglass luminaire with a nominal system lumen output of 3700 lumens and a minimum system efficacy of not less than 110 lumen/watt. The luminaire should have cool white colour temperature and a CRI>70. The luminaire shall meet IP65, IK 08 rating with THD<10% & Pf>0.9. The luminaire housing should be made of pressure die cast aluminium. The total power consumption should not exceed 34W(including driver). |
| 160 | Supply of LED Highbay with a nominal system lumen output of 16500 lumens and a minimum system efficacy of 125 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a colour temperature of 6500K and CRI > 80 and SDCM<4. The luminaire shall meet IP66 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with narrow beam optics and having gasket of heat proof silicone rubber ring. The total power consumption should not exceed 132W (including driver). |
| 161 | Supply of LED 4ft Slim LED Tube light fixture with one no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 18W (including driver). |
| 162 | Installation, Testing and Commissioning of following LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, PVC conduit bushes, Cu cable lugs as per tender specifiction. (Note: For Item 163 to 174 below) |
| 163 | Installation, Testing & Commissioning of 4ft LED Tube light fixture with 2x14W LED tube with a nominal system lumen output of 4200lm, min 150lm/W efficacy, CCT 6500K and CRI>80, THD<15%, PF>0.9, 4ft LED tube. The luminaire shall meet IP20 rating, SDCM< 7 and RoHS compliant. The fixture shall have single piece construction made of white powder coated CRCA sheet steel suitable for above LED tube light. The LED shall be mounted on extruded aluminium strip which acts as heat sink and is integral part of tube which is made up of extruded poly-carbonate material which gives diffuses light. The total power consumption should not exceed 28W (including driver). |
| 164 | Installation, Testing & Commissioningof LED Recessed 2ft x 2ft Luminaire with a nominal system lumen output of at least 4200 lumens and a minimum system efficacy of 120lm/W. The luminaire should have a CCT of 6500K, CRI>80, UGR<22% and SDCM<=5. The luminaire shall meet IP20 rating with THD<10% and PF>0.95. The luminaire housing should made of powder coated metallic CRCA with high effeciency PMMA diffuser. The total power consumption should not exceed 35W (including driver). |
| 165 | Installation, Testing & Commissioning of LED Circular Recessed downlighter with a nominal system lumen output of 1500lm and a minimum system efficacy of 100lm/W. The luminaire should have a CCT of 6500K and CRI> 80. The luminaire shall meet IP20 rating with THD<10%, PF>0.95. The luminaire housing should made of polycarbonate with high effeciency diffuser. The total power consumption should not exceed 14W (including driver). |
| 166 | Installation, Testing & Commissioning of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 167 | Installation, Testing & Commissioningof LED integral driver Flood light with a nominal system lumen output of 8400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 70W (including driver). |
| 168 | Installation, Testing & Commissioning of LED integral driver Flood light with a nominal system lumen output of 18000 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 150W (including driver). |
| 169 | Installation, Testing & Commissioning of 2 x 36W, 240V, 50Hz, FTL flame proof industrial luminaire suitable for wall mounting complete with heat resistant glass cover, low loss copper ballast, capacitor, lamp, 2nos cable entry nipple, wiring etc. |
| 170 | Installation, Testing & Commissioning of LED integral driver Flood light with a nominal system lumen output of 4200 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 6500K and a CRI>70. The luminaire shall meet IP65 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 35W (including driver). |
| 171 | Installation, Testing & Commissioning of 4ft Functional Batten (approx dim.140mm x 105mm x 1219mm)with 40W LED Tubelight (acid & corrossion proof) with a nominal system lumen output of 4800 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95. The luminaire housing should made of • Body - glass reinforced polyester (GRP), RAL 7035 • Gasket - polyurethane • Diffuser - UV stabilised prismatic acrylic material. The total power consumption should not exceed 40W(including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 172 | Installation, Testing & Commissioning of LED wellglass luminaire with a nominal system lumen output of 3700 lumens and a minimum system efficacy of not less than 110 lumen/watt. The luminaire should have cool white colour temperature and a CRI>70. The luminaire shall meet IP65, IK 08 rating with THD<10% & Pf>0.9. The luminaire housing should be made of pressure die cast aluminium. The total power consumption should not exceed 34W(including driver). |
| 173 | Installation, Testing & Commissioning of LED Highbay with a nominal system lumen output of 16500 lumens and a minimum system efficacy of 125 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a colour temperature of 6500K and CRI > 80 and SDCM<4. The luminaire shall meet IP66 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire housing should made of High Pressure die cast Aluminium with narrow beam optics and having gasket of heat proof silicone rubber ring. The total power consumption should not exceed 132W (including driver). |
| 174 | Installation, Testing & Commissioning of LED 4ft Slim LED Tube light fixture with one no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 18W (including driver). |
| 175 | Supply of heavy duty hot dipped GI conduit pipe as per IS 9537 along with all accessories such as inspection bends, junction box, socket, check nut, fish wire etc. including making threads, bends, removing burrs, connection of accessories, drawing of fish wire, beam and wall, cutting & Laying in brick wall, etc. as required under the instruction of Engineer-in-incharge. Surfacr mounted Junction box of suitable size as required suit at site shall be provided. (Note: For Item 176 to 177 below) |
| 176 | Supply of heavy duty Galvanised steel (G.I.) ERW conduit pipe of size 25 MM |
| 177 | Supply of heavy duty Galvanised steel (G.I.) ERW conduit pipe of size 40 MM |
| 178 | Embedment of heavy duty hot dipped GI conduit pipe as per IS 9537 along with all accessories such as inspection bends, junction box, socket, check nut, fish wire etc. including making threads, bends, removing burrs, connection of accessories, drawing of fish wire, beam and wall, cutting & Laying in brick wall, etc. as required under the instruction of Engineer-in-incharge. Surfacr mounted Junction box of suitable size as required suit at site shall be provided. (Note: For Item 179 to 180 below) |
| 179 | Fixing by surface conduiting of heavy duty Galvanised steel (G.I.) ERW conduit pipe of size 25 MM |
| 180 | Fixing by surface conduiting of heavy duty Galvanised steel (G.I.) ERW conduit pipe of size 40 MM |
| 181 | Supply of following size flexible GI conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. (Note: For Item 182 below) |
| 182 | Supply of flexible GI conduit pipe of size 26 MM |
| 183 | Installation of following size flexible GI conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. (Note: For Item 184 below) |
| 184 | Installation of flexible GI conduit pipe of size 26 MM |
| 185 | Supply of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 (latest edition) and as per conductor class 2 of IS: 8130/1984 as per technical specification (Note: For Item 186 to 187 below) |
| 186 | Supply of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 187 | Supply of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 188 | Installation/drawing through concealed/ surface conduit and wiring and termination at both ends of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 as per conductor class 2 of IS:8130/1984 as per technical specification. (Note: For Item 189 to 190 below) |
| 189 | Installation/drawing of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 190 | Installation/drawing of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 191 | Supply, Fabrication and Installation of Standard steel sections as per IS 2062 Grade BR for light frame, base frame, wall frames, brackets for supporting equipments and cable tray supports, clamps for GI rods etc. including all accessoriessuch as 8/12mm anchor fastner, SS screw, bolts etc. Fabrication shall include drilling, entiling, welding by qualified welder, wire brush cleaning, testing DPT etc., supply of all consumables like gas, approved welding rods as per EIC and tender tech spec. After fabrication two coats of epoxy based primer and two coats of finish paints shall be applied. |
| 192 | Supply and laying of 95 sq. mm Class-2 stranded bare tinned copper conductor underground upto depth of 1 meter, including excavation, connection with earth pit at one end and connection with test link box at other end, including clamping, connection through brazing/ bolting , refilling the trench etc. as per instructions by Engineer-In-Charge. (Note: For Item 193 to 194 below) |
| 193 | Supply of 95 sq. mm Class-2 stranded tinned copper conductor underground upto depth of 1 meter |
| 194 | Installation of 95 sq. mm Class-2 stranded tinned copper conductor underground upto depth of 1 meter |
| 195 | Supply and surface/concealed laying of 95 sq. mm stranded tinned coper conductor, including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. Brazing is considered as separate item in this tender. (Note: For Item 196 to 197 below) |
| 196 | Supply of 95 sq. mm stranded tinned coper conductor |
| 197 | Installation of 95 sq. mm stranded tinned coper conductor |
| 198 | Supply and surface/concealed laying including making chasing on wall of 10 sq. mm stranded tinned coper conductor, connection with earth pad at one end and DBs/ sockets/ motor at other end including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. (Note: For Item 199 to 200 below) |
| 199 | Supply |
| 200 | Installation |
| 201 | Supply and surface/concealed laying of 2 x 10 sq. mm Cu PVC insulated earthing conductor in 25 mm HDPE pipe including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. (For item nos. 202 to 203 below) |
| 202 | Supply |
| 203 | Installation |
| 204 | Supply and installation of 25 mm HDPE pipe as per tender specifications. |
| 205 | Soil Excavation: Excavation in all type of soils of width 500mm and a depth upto 1000 mm below ground level, back filling, disposal of excess earth. |
| 206 | Supply and installation of tinned Cu Lugs suitable to following sizes of earthing conductors with suitable brass bolts as per attached technical specification (Note: For Item 207 to 208 below) |
| 207 | 95 Sq.mm stranded tinned copper conductor |
| 208 | 10 Sq.mm stranded tinned copper conductor |
| 209 | Supply and installation of M10 brass nut bolt, 3/4\\" long suitable for 10mm threaded hole for making connection to earth pad. |
| 210 | Supply and installation of test link box for earth pit connection and interconnection of conductor to earth pit and should consist of 2mm thick powder coated pre-galvanised G.I. weather proof sheet enclosure with cover, having 50mm x 4mm copper strip link, teflon sealing after connection, earthing stud, etc as required. (Note: For Item 211 to 212 below) |
| 211 | Supply of test link box |
| 212 | Installation & Testing of test link box |
| 213 | Supply of Busbar Insulator of size M8 x 40mm, MOC: Epoxy as per tender specification. |
| 214 | Installation of Busbar Insulator of size M8 x 40mm for fixing of downcomer conductor from lightening arrestor as per tender specification. |
| 215 | Supply and Installation of 25 mm X 3 mm thick copper strip including connection/ terminating with nut, bolt, spring, washer etc. as required. (Note: For Item 216 to 217 below) |
| 216 | Supply of 25 mm X 3 mm thick copper strip |
| 217 | Installation & Testing of 25 mm X 3 mm thick copper strip |
| 218 | Supply and fixing vertical air termination made up of 20mm dia, 1mtr long copper rod attached to 145mm dia Copper sphere having drilled and tapped holes for fixing 5nos. Of 390mm long spikes and square copper base plate of 150mm length and 10mm thickness as per technical specification and approved drawing. (Note: For Item 219 to 220 below) |
| 219 | Supply of vertical air termination |
| 220 | Installation of vertical air termination |
| 221 | Supply, Installation, Testing and Commissioning of Ceiling mounted dual type occupency sensor with inbuilt or external power pack and auxiliary relay having min 15mtr sensing range in 180deg orientation and time delay ranges from 30sec to 30min and should have output relay capacity of 1000W (for LED lighting fixtures). (Note: For Item 222 to 223 below) |
| 222 | Supply of Ceiling mounted dual type occupency sensor |
| 223 | Installation, Testing and Commissioning of Ceiling mounted dual type occupency sensor |
| 224 | Supply, Installation, Testing and Commissioning of Occupancy sensor bypass switch box having 3pole rotary switch fixed on GI enclosure with cover. (Note: For Item 225 to 226 below) |
| 225 | Supply of Occupancy sensor bypass switch box |
| 226 | Installation, Testing and Commissioning of Occupancy sensor bypass switch box |
| 227 | Supply of required material and making of exothermic brazing joints of copper conductor with other conductor or copper earthing pad including removal of burrs and debris as per technical specification and instruction of engineer in charge. |
| 228 | Supply and Installation of GI Anchor Fastner of size M8x80 MM by drilling through concrete block as per site requirement for fixing plate Eps or other structures as per the tender specification. (Note: For Item 229 to 230 below) |
| 229 | Supply of GI Anchor Fastner of size M8x80 MM |
| 230 | Installation of GI Anchor Fastner of size M8x80 MM |
| 231 | Supply and Installation of 1.2 mm thick pre-galvanized GI sheet cover plates including marking, cutting (as per site requirement) and fixing on top of JB openings in wall and slab bottom/ ceiling at approx height of 5mtrs as per tender specifications. (Note: For Item 232 to 239 below) |
| 232 | Supply of switch box set consisting of 1 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 233 | Supply of switch box set consisting of 2 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 234 | Supply of switch box set consisting of 3 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 235 | Supply of switch box set consisting of 4 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 236 | Installation, Testing and Commissioning of switch box set consisting of 1 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 237 | Installation, Testing and Commissioning of switch box set consisting of 2 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 238 | Installation, Testing and Commissioning of switch box set consisting of 3 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 239 | Installation, Testing and Commissioning of switch box set consisting of 4 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 240 | Supply of 2 nos. of 6/16A (compatible with both 6A and 16A with shutter), Single phase Modular Decorative Type Socket with Polycarbonate box as required, 16A Switch and heavy duty polycarbonate Face Plate, 2 nos. of 16A plug tops and suitable mounting arrangements as per technical specification |
| 241 | Supply of 1 nos. of 6/16A ( compatible with both 6A and 16A with shutter) Single phase Modular Decorative Type Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. |
| 242 | Installation, Testing and commissioning of 2 nos. of 6/16A (compatible with both 6A and 16A with shutter), Single phase Modular Decorative Type Socket with Polycarbonate box as required, 16A Switch and heavy duty polycarbonate Face Plate, 2 nos. of 16A plug tops and suitable mounting arrangements as per technical specification |
| 243 | Installation, Testing and commissioning of 1 nos. of 6/16A ( compatible with both 6A and 16A with shutter) Single phase Modular Decorative Type Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. |
| 244 | Supply of RJ11 socket with polycarbonate box, Heavy duty polycarbonate front plate complete with all accessories for surface mounting. |
| 245 | Installation of RJ11 socket with polycarbonate box, Heavy duty polycarbonate front plate complete with all accessories for surface mounting. |
| 246 | Supply 2 Pair 0.6sqmm copper conductor Telephone cable as per tender specifications. |
| 247 | Installation 2 Pair 0.6sqmm copper conductor Telephone cable as per tender specifications. |
| 248 | Supply of 100 Pair x 0.5 sq.mm jelly filled armoured telephone cable on cable tray in trench or overhead or cleating on wall/ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 249 | Laying of 100 Pair x 0.5 sq.mm jelly filled armoured telephone cable on cable tray in trench or overhead or cleating on wall/ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 250 | Supply of 1 Pair x 1.5 Sq.mm twisted pair PVC insulated, HFFR PVC outer sheath, stranded copper conductor, flexible cable in existing laid concealed or surface conduit. |
| 251 | Laying of 1 Pair x 1.5 Sq.mm twisted pair PVC insulated, HFFR PVC outer sheath, stranded copper conductor, flexible cable in existing laid concealed or surface conduit. |
| 252 | Supply of 20 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor, armoured cable on cable tray in trench or overhead or cleating on wall / ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 253 | Laying of 20 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor,armoured cable on cable tray in trench or overhead or cleating on wall / ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 254 | Supply of Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 50 + 50 pairs of Telephone cable as per the technical specification. |
| 255 | Installation, Testing and Commissioning of Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 100+100 pairs of Telephone cable as per the technical specification. |
| 256 | Supply of Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 100+100 pairs of Telephone cable as per the technical specification. |
| 257 | Installation, Testing and Commissioning of Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 100+100 pairs of Telephone cable as per the technical specification. |
| 258 | Supply of Indoor type double enclosure, Floor Moutble Stand(M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 400 + 400 pairs of Telephone cable as per the technical specification. |
| 259 | Installation, Testing and Commissioning of Indoor type double enclosure, Floor Mountable Stand(M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 300 + 300 pairs of Telephone cable as per the technical specification. |
| 260 | Supply 50 Terminal Junction Box for PA System as per Tender specification. |
| 261 | Installation 50 Terminal Junction Box for PA System as per Tender specification. |
| 262 | Supply 4 Terminal Junction Box for PA System as per Tender specification. |
| 263 | Installation 4 Terminal Junction Box for PA System as per Tender specification. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail