|
| 1 | Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m : Ordinary rock. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 4 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 5 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 6 | P/F signboard on double retro 3 mm vinyl on ACP sheet 3 mm, blue base with computerized reflective vinyl coating and pasiting andfixing complete as per direction of Engineer-in-charge |
| 7 | Providing and fixing Building Entrance signage / Tactile Layout/ Emergency Evacuation Layout on the wall or with any other required structure with provision of multilingual text integral with 4mm thick blue Acrylic base plate with min 0.5 mm Aluminum sheet at the back with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised above base plate by not less than 0.8mm and the equivalent word/s written in Hindi / any language as required with same specifications with Grade 1 Braille to be integral with the sign face and should be raised 0.5mm above Acrylic base plate Each signboard to be fixed strictly as per the harmonized guidelines & space standards for Barrier Free Built Environment for persons with Disability issued By MOUD Govt. of India and as per approved drawings and complete as per the directions of Engineer - In - Charge {i)Payment for structure if required shall be paid separately ii) Size of the Signboards shall be proportional te the layout plan of the particular building. |
| 8 | Providing and fixing Golden Stainless Steel Letters (Grade 304) of 1.2mm thick, fixed on wall or any other surface, including necessary screws, fasteners, adhesives, and all required accessories complete in all respects, as per the direction of the Engineer-in-Charge. Please Enable Macros to View BoQ information |