| 1 | Demolition of brick work or stone masonry built in cement mortar including all quoines aches pillar etc but excluding ashlar facing dressed stone work and precast concrete articles all as specified. |
| 2 | Demolition of cement concrete (unreinforced) in any position i.e. floors and pavings etc nexc 15 cm thick (below or above G.L.) complete all as specified and as directed. |
| 3 | Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius butt in CM 1:6 complete all as specified and as directed. |
| 4 | All as per serial item no 3.00 here in before but but except bicks |
| 5 | M&L for half brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius but in CM 1:4 complete all as specified and as directed. |
| 6 | Walling of random rubble masonry built in cement motar 1:6, uncoursed, well bounded, bedded and solidly hearted complete all as specified and as directed. |
| 7 | All as per serial item no 6.00 here in before but except stones. |
| 8 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out jopints, hacking for key, scrubbing down with water complete all as specified and as directed. |
| 9 | 15mm thick rendering on fair faces or brick / concrete surfaces in cement mortar 1:4 and finishes even and smooth without using extra cement complete all as specified and as directed. |
| 10 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm, in any type of soil, complete all as specified and as directed. |
| 11 | Removing excavated material (soil) to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point, complete all as specified and as directed . |
| 12 | PVC (SWR) pipe 110mm dia single socket in any length with rubber ring joints fixed to wall / floor including PVC clamps complete all as specified and as directed. |
| 13 | Plain cement concrete 1:2:4 type B-1 using 20mm graded aggregate as in coping, kneelers, bed block including necessary from work complete all as specified and as directed. |
| 14 | Preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. |
| 15 | M&L two coat of synthetic enamel paint on steel surface over one coat of priming with red oxide, zinc chrome of any description over 10 cm in width or girth, notother wise described including preparation of surfaces complete all as specified and as directed. |
| 16 | M&L finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)(as camouflage Painting multicoloured complete all as specified and as directed. |
| 17 | Plain cement concrete in foundation filling and mass concrete type D-2 (1:4:8) using 40 mm graded crushed stone aggregate as in foundation complete all as specified and as directed. |
| 18 | Plain cement concrete 1:2:4, B-1 (20mm graded crushed stone aggregate) as in surface channels and drains etc complete all as specified and directed. |
| 19 | Dismantling of wrought iron or mild steel work of any decription not otherwise provided for complete all as specified and as directed. |
| 20 | Mild steel work as in posts & struts in fencing including cutting tops to shape as directed drilling holes, notching for wire etc & similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 21 | Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, stapples or steel pins, etc as directed (each line wire to be measured) complete all as specified and as directed. |
| 22 | S&F in replacement concertina coil, punched type (including spike and handle) with 50/51 turns and dia 600mm, having a 2.6mm dia core wire of high carbon spring steel of high tensile strength. The punched tape and core wire are electrogalvanized to provide protection against outdoor exposure. The punched tape is mechanically crimped over the cover wire and then formed into a coil at various parts of the periphery of the coil steel clips connect the individual turns of the coil to each other so that it opens up like an accordion. The weight of each coil will be 9 KG (+/- 5%) without packing material and coil length 7 to 8 mtr when opened up. Each coil wound with bituminized Hession cloth for providing protective coating, complete all as specified and directed. |
| 23 | Mild steel framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work hung as gates, including pintle hinges, stops,hand-made sliding bolts,and ornamental and intricate design etc conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 24 | Mild steel work in Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hangingdoor fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete fastening and fixing complete Fe -410 Gde E-250 complete all as specified and as directed. |
| 25 | Mild steel, plain, black sheet 1.25 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed. |
| 26 | Plain cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregates as in floors 75mm thick complete all as specified and as directed. |
| 27 | Machine pressed coloured concrete interlocking paver block glossy finish, any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment complete all as specified and as directed. |
| 28 | 25mm thick Sand cushioning /filling under floors complete all as specified and as directed. |
| 29 | M&L for factory made coloured glossy finish chequred cement concrete tile size 30cmx 30cm x 25mm thick machine pressed set & jointed in neat cement slurry as in floors joint fiil up with white grey cement & pigments all including 15mm thick screed bed with CM 1:4 complete all as specified and as directed. |
| 30 | Providing precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in kerb stone and similar work, bedded and jointed in CM 1:6 complete all as specified and as directed. |
| 31 | Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 32 | RCC M-25 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 33 | RCC M-25 (using 20 mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like including 15 mm th plastering with water proofing compound as directed laid/made to slope as in RCC roof surfaces complete all as specified and as directed. |
| 34 | Use and waste of formwork to sides of concrete foundations, footings, bases ofcolumns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter complete all as specified and as directed. |
| 35 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and as directed. |
| 36 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed. |
| 37 | Mild steel TMT bars, 10mm dia and over cut to length, bent to shape required, incl cranking bending, spirally for hooping for columns, hooking ends and binding with and ind incl MS wire annealed not less than 0.90 mm dia or securing with clips complete all as specified and as directed. |
| 38 | Mild steel TMT bars, 6mm to 8 mm dia as in reinforcement , cut to length,bent to shape required, including cranking, bending spirally for hooping for coh, .nns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 39 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum, in any type soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil complete all as specified and as directed. |
| 40 | Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation for fencing post filling, and mass concrete, complete all as specified and as directed. |
| 41 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and as directed. |
| 42 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire only complete all as specified and as directed. |
| 43 | Holes drilled up to 12mm dia (and countersunk, if required) depth of holes exc 3mm but nexc 12mm complete all as specified and as directed. |
| 44 | Providing precast cement concrete louvers and jallies, 50 mm thick ( measured solid) including all mouldings but excluding frame type B-0 1:2:4 ( 12.5 mm graded crushed stone aggregate) set in CM 1: 4 complete all as specified and as directed. |
| 45 | Dismantling of CGI/AC/ any others sheet of any description including ridges etc complete all as specified and as directed. |
| 46 | Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding/view cutter to wall fixed with self tapping screws complete all as specified and as directed. |
| 47 | 18 mm to 20 mm thick granite (of any type),18 to 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. Please Enable Macros to View BoQ information |