| 1 | Schedule 'A' |
| 2 | Excavation in trenches for Soft/Disintegrated rock n.exc 1.5 m wide and n.exc 1.5 m deep and getting out for taking out/laying of UG cable.LT of any size complete all as specified and directed by Engr In charge |
| 3 | Excavation in trenches for Hard/Dense soil n.exc 1.5 m wide and n.exc 1.5 m deep and getting out for taking out/laying of UG cable.LT of any size complete all as specified and directed by Engineer - in - Charge |
| 4 | Returning and filling in trenches incl spreading, levelling watering and raming in layer n.exc 25 cm complete all as specified and directed. |
| 5 | Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed by Engr In charge |
| 6 | M&L and Repair/Replacement for erecting of Prestressed concrege pole 9.0 metres long, 102x152mm at top and 102x289mm at bottom, class 10 complete all as specified and directed by Engr In charge |
| 7 | Material and labour for painting to Prestressed concrege pole 9.00 metre long two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge |
| 8 | Material and labour for numbering of pole No. Using radium sticker of superier quality with back of Black round and fonts with white in colour complete all as specified and directed by Engineer-in-Charge. |
| 9 | S&F in replacement on pole street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron of suitable size 02 Nos incl nut bolts Etc of suitable size complete all as specified and directed by Engr In charge |
| 10 | Supply and Repair/Replacement of hot press moulded SMC junction box door fixed with left side hinged inside dimension of 240x130x95 mm Fixed with cable terminals with one number of 16 Amp SP MCB incl fixed on pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.Make-Sintex/Hensal/National |
| 11 | Supply and Repair/Replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole/post/wall position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s street light fittings. |
| 12 | Supply and Repair/Replacement of flood light LED luminaire white150 watt IP -65 flood light with highlighting architecturel facade highmast/basket ball court/squach court/batmittan court light complete all as specified and directed including taking down the u/s flood light fittings.Havells/C&S/CG |
| 13 | Supply and Repair/Replacement of Laying in trenches or passing through pipe,16 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duty for 1100 volts grade cross sectional area complete all as specified and as directed. |
| 14 | Supply and Repair/Replacement of Laying in trenches or passing through pipe,25 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duty for 1100 volts grade cross sectional area complete all as specified and as directed. |
| 15 | Supply and Repair/Replacement of Laying in trenches or passing through pipe,10 Sqmm 2 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and directed by Engineer - in - Charge |
| 16 | Supply and lay in replacement Double Walled Corrugated (DWC) Pipes having 50mm dia corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size upto 50 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. |
| 17 | Supply and lay in replacement Double Walled Corrugated (DWC) Pipes of dia 40mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 40 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. |
| 18 | Supply and Repair/Replacement for 200 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T |
| 19 | Supply and Repair/Replacement for 100 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustabletypeagainst over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T |
| 20 | M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI strips 25 x 4 mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed. |
| 21 | M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI lead 40mm dia mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed. |
| 22 | M&L in Replacement of earthing complete with Copper earth plate electrode of size 60cm×60cm ×3.15mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to earthing copper strip of size 20×3mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed. |
| 23 | Supply ony Lug aluminium suitable cable size of 16 to 50 sqmm complete all as specified and directed Engineer-in-Charge. |
| 24 | Supply ony Lug aluminium suitable cable size of 50 to 120 sqmm complete all as specified and directed Engineer-in-Charge. |
| 25 | Taking out panel door with old broken hinges and supply and fix with new MS hinges medium weight of 75mm long fix to panel & panel door with suitable nut & bolt /welding and Painting of LT panel with two coats of synthetic enamel paint of existing colour complete exc 5 sqm n exec 10 sqm complete all as specified and directed. |
| 26 | Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70sqmm to 120 sqmm complete all as specified and directed Engr-in-Charge.Make :- 3M/Raychem |
| 27 | Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 70 sqmm complete all as specified and directed Engr-in-Charge.Make :- 3M/Raychem |
| 28 | M&L for Repeir/Replacement of panel mounted volt meter digital type 3 phase as per existing complete all as specied and directed |
| 29 | M&L for Repeir/Replacement of panel mounted Ammeter digital type 3 phase as per existing complete all as specied and directed |
| 30 | M&L for Cement Concrete 1:4:8 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required), complete all as specified and as directed. |
| 31 | M&L for Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) as in Coping of Poles, etc. including Formwork (as/if required), complete all as specified and as directed. |
| 32 | M&L for Cement Concrete 1:3:6 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required), complete all as specified and as directed. |
| 33 | Supply and Repair/Replacement for Timer switches Digital type programmable for street light connected to contactor complete all as specified and directed. |
| 34 | Supply and Repair/Replacement of power contactor 3 pole MCX-04 suitable for street light connected to timer complete all as specified and as directed.Make - L&T/C&S/Havells |
| 35 | Supply and Repair/Replacement of MCB SP 6-32Amps,10 KA breaking capacity 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge. |
| 36 | Supply and Repair/Replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.Make:- Anchor/C&S/L&T |
| 37 | Supply and Repair/Replacement of new generation post top energy saving environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IP65 suitable for pole dia 76 mm with 25 watt LED lamp complete all as specified and directed by Engineer - in - Charge. Make :- Havells Cat No:-CORALPT25WLED757PSYMTOPC or its equivalent in Bajaj/C&S |
| 38 | Supply and Repair/Replacement of Garden Bollard light BGBOM 650 9W LED Bollards lightDie cast aluminium graphite grey powder coated GI Pipe Housing ,Mushroom shape opal acrylic diffuser if fixed in die-cast aluminium base for pleasant light output,LED mounted on die-cast aluminium base,IP-65, 240 Volt,Luminaire is provided with base plate and fixing holes for directely mounting on the concrete pedestal including including taking down the u/s street light fittings complete all as specified and as directed.Catpart No. BAMBOOBL8WLED857PSYMTOPCM of Havells Make or its equivalent in Bajaj/C&S/Wipro. |
| 39 | Supply and Repair/Replcement for weather proof flat twin core 6 sqmm multistrand Copper conductor cable complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and Repair/Replacement for Cable with copper conductor PVC round sheathed (flexible) 3 core 4 sqmm industrial cable complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply & Fixing in replacement of installation, testing and commissioning factory made, floor mounted outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Aluminium bus bar 200Amp rated four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.15 mm of outer body and inner body 2.00 mm thick CRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:- (Make :- CPRI Approved)(a) MCCB Thermal magnetic based 100 Amp, FP, 415 Volt, 25 KA - 01 No (Incoming)(b) MCCB Thermal magnetic based 63 Amps, 25 KA, FP, 415 Volt - 02 No (O/G) (c ) MCB 63 Amps, 10 KA, TPN, - 02 Nos (O/G) (d) Power Contactor 3 Pole 63 Amps Make : HAVELLS - 01 No (e)Multifunctional Timer switch digital type for street light ON/OFF Make :HAVELLS - 01No (f)Digital Ammeter -01 No (g)Digital Voltmeter -01 No(h)CT Rating 100/5 (i) Indicating lamp LED Type-RYB-01 Set |
| 42 | Supply and fix Octagonal Hot- Dip galvanized street light pole including junction box with double arm bracket of following sopecification - Height 7Mtrs, top dia 70mm, bottom dia 130 mm, sheet thickness 3mm base plte 220x220x12mm with foundation bolt (M20X750) 04Nos including PCC Foundation of depth not less than 60cm Make- Utkarsh,Bajaj or equivalent including taking out old PCC/Steel Tubular Pole complete all as specified and directed. |
| 43 | Supply and fixing inreplacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr In charge |
| 44 | Supply and Repair/Replacement of LED Solar street light fitting 15 Watt including in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed by Engineer - in - Charge Make-Havells/Surya/Bajaj |
| 45 | Supply and Repair/Replacement of flood light LED luminaire white 200/210 watt IP -65 flood light with highlighting architecturel facade highmast/basket ball court/squash court/batmittan court light complete all as specified and directed including taking down the u/s flood light fittings.Havells/C&S/CG |
| 46 | Supply and fix of Integral LED aviation luminaire light comprising of aluminium housing with polycarbonate enclosure complete in highmast light in position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s aviation light fittings. |
| 47 | Supply and Repair/Replacement of decorative gate light moon (opal) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and 1.5Mtr mm pole dia50mm with 7/9 watt LED lamp complete PCC Foundation all as specified and direcred by Engineer-in-Charge |
| 48 | Supply & Fixing in replacement of Fire Alarm sounders / Sirens electronictype horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5db 1500m range complete all as specified and directed. |
| 49 | Supply & Fixing in replacement of Addressable manual call point resettable type complete all specified and directed. |
| 50 | Disconnecting and taking out damaged existing any type strip and S&F of copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed. |
| 51 | Supply and fix in repair Mild Steel class 'C' diesel pump exhaust pipe 80/100mm dia of length 10mtr with one layer of 10mm thick asbestos rope insulation and including all fitting clamp/ Welding and structural steel supports complete |
| 52 | Desconnecting and taking out unserviceable any type Air termination rod and S&F of Air termination, single pointed copper rod 12mm dia and 300mm long all as specified and directed. |
| 53 | Desconnecting and taking out unserviceable Test point terminal block and supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed. |
| 54 | Supply and Repair/Replacement of poroceline insulator for laying of ligtning strip on the roof/ wall for maintain distance from suface and strip of suitable size and distance between two insulator minimum 1mtr complete all as specified and directed. Please Enable Macros to View BoQ information |