| 1 | S&F exhaust fan, steel body, AC single phase. 230 V of size 300 mm sweep with blades and frame and louvers, hanging on wall with 4 Nos steel fasterners 10mm dia & 100mm long including wall hole and making good the disturbed surfaces as per existing complete all as specified & directed |
| 2 | S&F ceiling fan complete with blades,clamp, hooks,down rod and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) with remote control and fixing of hooks by anchor fastner including connecting from ceiling rose/connector with & including flexible copper cable of suitable size complete all as specified and directed |
| 3 | S&F electric water heater of capacity 25 litres,BEE 5 Star rated,storage type, steel body vertical type with glass lined /porcelain enamel coated steel inner tank and glass line double ceramic heating element upto 2 KW complete with all accessories such as safety valve,thermostate NRV,connection piece etc and fixing with 04 Nos nut bolt grouting in wall in PCC 1:2:4 (using 12.5mm graded crushed stone aggregate) for hanging the geyser and making good the disturbed surface complete all as specified and directed |
| 4 | M&L for point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLSH with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed medium grade conduit of suitable size with all accessories such as bend, reducers, MS hooks including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc including continuous earth wire of size 1.5 Sqmm PVC FRLSH stranded copper conductor unsheathed, insulated, stranded connected to common earth point dolly for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed . Note:- Proper colour coding is to be followed as per IS specifications. |
| 5 | All as per srl item No 4 here-in-before but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 sqmm for point wiring and 2.5 sqmm as in continuous earth wire. |
| 6 | S&F modular type switch, one way 6 Amps , 1 module complete all as specifieds and directed . |
| 7 | S&F ceiling rose, surface backelite, two/ three terminal, 240 volts complete all as specifieds and directed . |
| 8 | S&F modular type fan regulator step down 120 watt, 2 module complete all as specified and directed . |
| 9 | S&F Socket Residual Current Device (SRCD) with steel enclosure including MCB,SPN 25 Amps,240 V, AC supply & plug top 15/16 Amps complete all as specified and directed. |
| 10 | S&F Galvanised steel tubing, 15mm bore, medium grade with all fittings, fixed to wall with clamps /ceiling or laid in floors complete all as specified and directed |
| 11 | S&F angle valve ,cast copper alloy , fancy type, chromium plated, screwed down for high pressure , screwed both ends for iron pipe of 15mm bore complete all as specified and directed. |
| 12 | S&F PVC connection 15 mm x 600 mm including PVC check nut at both ends complete all as specified and directed. |
| 13 | S&F bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle , screwed down, screwed for 15 mm bore of iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 14 | Repair/Replacement of double skin Floor mounted Air Handling Unit with 25 mm thick PUF panel, pre filter section, SP 50mm, 6RD CHD & 2 RD heat coil, forward curved blower of capacity 11600 CFM, Fan model FDA-630, Fan Pulley dia 315 mm x 2A and motor pulley dia 125 mm/2A, Fan RPM 578, three phase motor 5.5 KW, four pole, 50 Hz complete all as specified and directed. |
| 15 | Repair/Replacement of double skin Ceiling mounted Air Handling Unit with 25 mm thick PUF panel, pre filter section, SP 50mm, 6RD CHD & 2 RD heat coil, forward curved blower of capacity 3270 CFM, Fan model KAT-9x9-S2, Fan Pulley dia 106 mm x 2A and motor pulley dia 100 mm/2A, Fan RPM 1364, three phase motor 2.2 KW, four pole, 50 Hz complete all as specified and directed. |
| 16 | M&L for MS chilled water piping duly insulated with 25 mm thick nitrile sheet, finally finished with glass colth and star bond complete all as specified and directed. |
| 17 | M&L for 50 mm WG Pressure gauge iron complete with SS syphon, cock valve and MS socket complete all as specified and directed. |
| 18 | M&L for stem type thermometer complete all as specified and directed. |
| 19 | M&L for 50 mm bore CI butterfly valve complete all as specified and directed. |
| 20 | M&L for 80 mm bore CI butterfly valve complete all as specified and directed. |
| 21 | M&L for 3 way iron control valve complete with actuator and thermostat complete all as specified and directed. |
| 22 | M&L for Flexible Canvas connection complete all as specified and directed. |
| 23 | M&L for Ducting with PGI sheet for connection piece complete all as specified and directed. |
| 24 | M&L for Acoustic insulation of duct with open cell nitrile sheet of 10 mm thick complete all as specified and directed. |
| 25 | M&L for taking down old unserviceable AHU for repair, commissioning , testing and refixing at same location after repair complete all as specified and directed. |
| 26 | Repair of double skin Floor mounted Air Handling Unit of ICU including replacement of both heating and cooling coils, external filters and cleaning with descaling solution complete all as specified and directed. |
| 27 | Repair/replacement of Electrical panel of AHUs including repalcement of MCCBs,digital voltmeter, digital ampere metre, push buttons red & green, indicators, replacement of cable of suitable size from panel to motor complete all as specified and directed. |
| 28 | Replacement of GI medium grade drain pipe of 25 mm dia complete all as specified and directed |
| 29 | Replacement of GI medium grade drain pipe of 20 mm dia complete all as specified and directed |
| 30 | M&L for rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces, surface finished even and smooth without using extra cement complete all as specified and directed. . |
| 31 | S&F mild steel work using angle iron of size 50x50x6mm for AHU complete all as specified and directed. |
| 32 | M&L for plain cement concrete 1:4:8, type D2 (using 40mm graded crushed stone aggregates) as in foundation, filling & mass concrete complete all as specified and directed. |
| 33 | S&F Rolled mild steel as in main and cross beams, vertical posts,hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe-410-W(Gde-E-250, quality-A) complete all as specified and directed |
| 34 | M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 35 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and directed. |
| 36 | S&F in replacement of V Belt No. A-26 for AHU complete all as specified and directed. |
| 37 | S&F in replacement of V Belt No. A-61 for AHU complete all as specified and directed.. |
| 38 | S&F HVAC Diffuser used in return air of central AC Plant of size 2'x2' , powder coated , Flush/Linear type, square in shape complete all as specified and directed. Please Enable Macros to View BoQ information |