| 1 | Schedule 'A' |
| 2 | Excavation in trenches for Hard /Dense soil n.exc 1.5 m wide and n.exc 1.5 m deep and getting out for taking out/laying of UG cable.LT of any size |
| 3 | Returning and filling in trenches incl spreading, levelling watering and raming in layer n.exc 25 cm complete all as specified and directed. |
| 4 | Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 5 | Supply and Repair/Replacement of laying/jointing GI Pipe light grade 50mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed. |
| 6 | Supply and Repair/Replacement of laying/jointing GI Pipe light grade 80mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed. |
| 7 | Supply and Repair/Replacement of Laying in trenches or passing through pipe,50 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed. |
| 8 | Supply and Repair/Replacement of Laying in trenches or passing through pipe,95 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed. |
| 9 | Supply and Repair/Replacement of Laying in trenches or passing through pipe, 240 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed. |
| 10 | Supply and Repair/Replacement of Laying in trenches or passing through pipe, 120 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed. |
| 11 | Supply and Repair/Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S |
| 12 | Supply and Repair/Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S |
| 13 | Supply and Repair/Replacement for 200 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S |
| 14 | Supply and Repair/Replacement for 160 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustabletype against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S |
| 15 | Supply and Repair/Replacement for 100 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustabletypeagainst over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S |
| 16 | Supply and Repair/Replacement for 63 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustabletypeagainst over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S |
| 17 | Supply and Repair/Replacement for 630 AMP ACB 4 Pole, 415 V, AC 50 Hz, 4 pole with Thermal Magnetic Release (Manual Drawout type) suitable of Existing panel board for replace of unserviseble ACB complete all as specified and directed. |
| 18 | Supply and Fix in replacement of Capacitor Bank MPP-H, 05 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed. Make : L&T or equivelant make. |
| 19 | Supply and Fix in replacement of Capacitor Bank MPP-H, 10 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed. Make : L&T or equivelant make |
| 20 | Supply and fixing in replacement of capacitor duty, contactor MO C5 complete all as specified and directed. Make : L&T or equivalent |
| 21 | S&F in replacement of aluminium bus bar PVC insulated in RED,yellow,Blue & Black colours of rating 400 Amps |
| 22 | S&F in replacement of aluminium bus bar PVC insulated in RED,yellow,Blue & Black colours of rating 600 Amps |
| 23 | M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI strips 25 x 4 mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed. |
| 24 | M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI wire 4.0mm dia by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed. |
| 25 | Supply only Lug aluminium suitable cable size of 50 to 150 sqmm complete all as specified and directed Engineer-in-Charge. |
| 26 | Supply only Lug aluminium suitable cable size of 16 to 50 sqmm complete all as specified and directed Engineer-in-Charge. |
| 27 | Supply only Lug Copper suitable cable size of 10 to 25 sqmm complete all as specified and directed Engineer-in-Charge. |
| 28 | Supply and Repair/Replacement of Onload change over switch 400 Amp four pole changeover, 415 Vac, 50 Hz by connecting the electrical connection and fixing on panal with nut, bolt,clamps complete all as specified and as directed by Engr-in-Charge. Make Havells/ ABB/L&T |
| 29 | Supply & Fixing in replacement of installation, testing and commissioning factory made, floor mounted outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Aluminium bus bar 600Amp rated, four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.15 mm of outer body and inner body 2.00 mm thick CRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:- Make :- CPRI Approved(a) MCCB Thermal magnetic based 400Amps 4 pole ,35 KA -01 No (Incoming)(b) MCCB Thermal magnetic based 400 Amps 4 pole ,25 KA (Outgoing) - 01 No(b) MCCB Thermal magnetic based 160 Amps 4 pole ,25 KA (Outgoing) - 01 No(c) MCCB Thermal magnetic based 100 Amps, 25 KA, FP, - 01 No (O/G) (d) MCB 32 Amps, 10 KA, SPN - 3 Nos (O/G) (Spare-01No)(g) Digital Ammeter with CT's and Selector switch-01 Set(h) Digital Voltmeter with selector switches-01 No(j) Digital Multifuntional Meter with selector switches - 01 No(k) Indicating lamp LED Type-RYB-01 Set |
| 30 | Supply & Fixing in replacement of installation, testing and commissioning factory made, floor mounted outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Aluminium bus bar 500Amp rated, four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.15 mm of outer body and inner body 2.00 mm thick CRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:- Make :- CPRI Approved(a) MCCB Adjustable Thermal magnetic based 400Amps 4P, 35 KA (Incomer) - 01 No(b) MCCB AdjustableThermal magnetic based 250 Amps 4P,25 KA (O/G) - 01 No(c) MCCB Fixed Thermal magnetic based 100 Amps 4P ,25 KA (O/G) - 23 Nos(d) MCCB Thermal magnetic based 63 Amps 4 pole ,25 KA (Outgoing) - 02 Nos(e) MCB 32 Amps, 10 KA, SPN - 4 Nos (O/G) (Spare-01No)(f) Digital Ammeter -01 No (g) Digital Voltmeter -01 No(h) Digital Multifuntional Meter with selector switches - 01 No(j) Indicating lamp LED Type-RYB-01 Set |
| 31 | Taking out panel door with old broken hinges and supply and fix with new MS hinges medium weight of 75mm long fix to panel & panel door with suitable nut & bolt /welding and Painting of LT panel with two coats of synthetic enamel paint of existing colour complete exc 5 sqm n exec 10 sqm complete all as specified and directed. |
| 32 | Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size150 sqmm to 240 sqmm complete all as specified and directed Engr-in-Charge.Make :- 3M/Raychem |
| 33 | Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70sqmm to 120 sqmm complete all as specified and directed Engr-in-Charge.Make :- 3M/Raychem |
| 34 | Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 70 sqmm complete all as specified and directed Engr-in-Charge.Make :- 3M/Raychem |
| 35 | M&L for Repeir/Replacement of panel mounted volt meter digital type 3 phase as per existing complete all as specied and directed |
| 36 | M&L for Repeir/Replacement of panel mounted Ammeter digital type 3 phase as per existing complete all as specied and directed |
| 37 | M&L for Cement Concrete 1:4:8 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required), complete all as specified and as directed. |
| 38 | M&L for Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) as in Coping of Poles, etc. including Formwork (as/if required), complete all as specified and as directed. |
| 39 | M&L for Cement Concrete 1:3:6 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required), complete all as specified and as directed. |
| 40 | M&L for Repair/Replacement for erecting of steel tubular swaged poles swan neck type complete with cast iron base plate, finial taper plug, Cap, mild steel bolts, nuts,screw, etc. type 410 SP-31(9.0 meters long) complete all as specified and directed. |
| 41 | M&L for Repair/Replacement for erecting of Prestressed concrege pole 9.0 metres long, 102x152mm at top and 102x289mm at bottom, class 10 |
| 42 | Material and labour for painting to Prestressed concrege pole 9.00 metre long two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge |
| 43 | Material and labour for painting to steel tubular pole 9.00 metre long with one coat of red oxide on pole and two coats of synthetic enamel aluminium paint complete all as specified and directed by Engineer-in-Charge |
| 44 | Material and labour for numbering of pole No. Using radium sticker of superier quality with back of Black round and fonts with white in colour complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F in replacement on pole street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron of suitable size 02 Nos incl nut bolts Etc of suitable size all as specified and directed by Engr In charge |
| 46 | Supply and Repair/Replacement of hot press moulded SMC junction box door fixed with left side hinged inside dimension of 240x130x95 mm Fixed with cable terminals with one number of 16 Amp SP MCB incl fixed on pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.Make-Sintex/Hensal |
| 47 | Supply and Repair/Replacement for Timer switches Digital type programmable for street light connected to contactor complete all as specified and directed. |
| 48 | Supply and Repair/Replacement of power contactor 3 pole MCX-04 suitable for street light connected to timer complete all as specified and as directed.Make - L&T/C&S/Havells |
| 49 | Supply and Repair/Replacement of MCB SPN 6-32Amps,10 KA breaking capacity 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge. |
| 50 | Supply and Repair/Replacement of MCB TP 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.Make:- Anchor/C&S/L&T |
| 51 | Supply and Repair/Replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.Make:- Anchor/C&S/L&T |
| 52 | Supply and Repair/Replacement of Building street light fitting Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down the u/s street light fittings complete all as specified and as directed. |
| 53 | M&L for repair and maintanance to solar street lights including cleaning of solar panel, filling of distilled water for battery,charging battary and making servicable complete all as specified and directed by Engineer - in - Charge. |
| 54 | Supply and Repair/Replacement of battary 12 volts 80 AH capacity suitable of solar light complete all as specified and directed by Engineer - in - Charge. Make: Exide/Luminious |
| 55 | Supply and Repair/Replacement of LED Solar street light fitting 15/16 Watt including in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete Make-Havells/Surya/Bajaj |
| 56 | Supply and Repair/Replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole/post/wall position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s street light fittings. |
| 57 | Supply and Repair/Replacement ofLED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole/post/wall position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s street light fittings. |
| 58 | Supply and Repair/Replacement ofLED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole/post/wall position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s street light fittings. |
| 59 | Supply and Repair/Replacement of flood light LED luminaire white 200/210 watt IP -65 flood light with highlighting architecturel facade highmast/basket ball court/squach court/batmittan court light complete all as specified and directed including taking down the u/s flood light fittings. |
| 60 | Supply and Repair/Replacement of flood light LED luminaire white 150 watt IP -65 flood light with highlighting architecturel facade highmast/basket ball court/squach court/batmittan court light complete all as specified and directed including taking down the u/s flood light fittings. |
| 61 | Supply and fix in replacement of Integral LED aviation luminaire light comprising of aluminium housing with polycarbonate enclosure complete in highmast light in position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s aviation light fittings. |
| 62 | Supply and Repair/Replacement of decorative gate light moon (opal) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and 60 mm pole dia with 7/9 watt LED lamp complete all as specified and direcred by Engineer-in-Charge |
| 63 | Supply and Repair/Replacement of new generation post top energy saving environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IP65 suitable for pole dia 76 mm with 25 watt LED lamp complete all as specified and directed by Engineer - in - Charge. Make :- Havells Cat No:-CORALPT25WLED757PSYMTOPC or its equivalent of Bajaj/C&S |
| 64 | Supply and Repair/Replacement of Garden Bollard light BGBOM 650 9W LED Bollards lightDie cast aluminium graphite grey powder coated GI Pipe Housing ,Mushroom shape opal acrylic diffuser if fixed in die-cast aluminium base for pleasant light output,LED mounted on die-cast aluminium base,IP-65, 240 Volt,Luminaire is provided with base plate and fixing holes for directely mounting on the concrete pedestal including including taking down the u/s street light fittings complete all as specified and as directed.Catpart No. BAMBOOBL8WLED857PSYMTOPCM of Havells Make or its equivalent of Bajaj/C&S/Wipro. |
| 65 | M&L for Shifting of poles 09 mtr long including all accessories (junction box, street light, service connection cable, clamp ) without any damage from one place to another place not exceeding 200 mtr and errection at new place. Poles shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth complete all as specified and directed. Necessary excavation and foundation are measured and paid separately. |
| 66 | Supply and Repair/Replacement for Laying in trenches or passing through pipe,10 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed. |
| 67 | Supply and Repair/Replacement for Laying in trenches or passing through pipe,16 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed. |
| 68 | Supply and Repair/Replacement for Laying in trenches or passing through pipe,25 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed. |
| 69 | Supply and lay Double Walled Corrugated (DWC) Pipes of dia 50mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 50 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. |
| 70 | Supply and lay Double Walled Corrugated (DWC) Pipes of dia 63mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 63 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. |
| 71 | Supply and lay Double Walled Corrugated (DWC) Pipes of dia 90mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 63 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. |
| 72 | Supply and Repair/Replcement for weather proof flat twin core 6 sqmm multistrand Aluminium conductor cable with PVC conduit of dia 25mm with accessories complete all as specified and directed by Engineer-in-Charge. |
| 73 | Supply and Repair/Replacement for Cable with copper conductor PVC round sheathed (flexible) 3 core 2.5 sqmm industrial cable complete all as specified and directed by Engineer-in-Charge. |
| 74 | Supply and Repair/Replacement for Cable with copper conductor PVC round sheathed (flexible) 3 core 4 sqmm industrial cable complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply and Repair/Replacement of LED Solar street light fitting 15 Watt with inbuilt solar charge controller with street light bracket suitable size including taking down the u/s solar light fittings compleate all as specified and as directed. sensor complete Please Enable Macros to View BoQ information |