| 1 | Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete |
| 2 | M&L for point wiring with 1.5 Sq.mm (nominal size) single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable confirming to IS 694:2010 with and including continuous earth wire of size 1.5 Sqmm (nominal size) single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353: 1985 drawan through and including rigid non-metallic PVC concealed conduit of 20mm dia (Nominal bore) or higher, medium grade confirming to IS 9537(Part 3): 1983 complete with and including all PVC conduit accessories and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM confirming to IS 14772 : 2000 having op, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover plate with frame and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732: 2019 and directed by Engr-in-Charge, for One light point controlled by one, one way switch 06 Amps, complete all as specified and directed. |
| 3 | All as per above item No 2 here-in-before but one Ceiling / exhaust fan point controlled by one, one way switch 5/6 Amps |
| 4 | All as per above item No 2 here-in-before but one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, one way 06 Amps switch |
| 5 | All as per above item No 2 here-in-before but one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch |
| 6 | All as per above item No 2 here-in-before but one 3 pin, 15 Amps socket outlet point on independent board 2.5 sqmm nominal cross sectional area controlled by one, one way 15 Amps switch |
| 7 | S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directedMake: Legrand/Indoasians/Havells |
| 8 | S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete Make: Legrand/Indoasians/Havells |
| 9 | S&F modular socket outlet 3 Pin, 06 Amps, 02 module with shutter complete Make: Legrand/Indoasians/Havells |
| 10 | S&F modular socket outlet 02 in 01, 3 pin, 6/16 Amps, 02 module with shutter complete Make: Legrand/Indoasians/Havells |
| 11 | S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete Make: Legrand/Indoasians/Havells |
| 12 | S&F sueface mounting LED integrated PVC housing batten with polycarbonate deffuser luminaire not less than 22 W, 4 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 2.5 KV, CCT 5700K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete. Make: Havells/Phillips/Wipro |
| 13 | S and F in replacement of size 6/8 inches dia and up to 15 Volt round LED panel recess/surface mounting downlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 145mm mm dia hight max 35mm recess luuminaries all as specified and directed. Make : Crompton / Halonix/ Havells |
| 14 | S&F in repair Supply and fixing LED luminaire 600 mm x 600 mm x 70mm 35/36 watt, 220 V AC recessed type with high efficiency life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 2.5 KV, CCT 5700K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete. Makes :- Eveready: LEDPLB03616-03NS, Havells:VENUSTREND2x2PLR36WLED865SWH & Philips: RC380BLED36S-6500G6L60W60PSU0DS1 Note for item 12 -14 : make of light fittings and driver shall be same and manufacturer shall have in house NABL accredited lab. |
| 15 | S&F surface mounted LED building security light fitting in high pressure die cast aluminium housing not less than 45 watt fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V including light grade GI tube mounting size 40MM bracket of suitable size & length, bend to shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete and one coat of primer and one coat of synthetic enamel paint after coating of primer on GI bracket and pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core complete all as specified and as directedMake: Havells/Phillips/Wipro |
| 16 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete . Make: Havells Model No. Efficiencia Neo (BLDC 26W)/Orient Model No AEON/ Cromption Model No Energin HS |
| 17 | M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring complete |
| 18 | All as in above item but with 2 X 4 Sqmm for Phase & Neutral and 1 X 4 Sqmm for earth complete all as specified & directed. |
| 19 | S&F (in replacement) sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and sheet metal enclosure double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Note - (a) MCB shall be measured and paid seprately under respectively item. (b) Make for the DB/MCB/MCCB shall be same.) |
| 20 | All as in above item but 12 way complete all as specified and directed.Make: Legrand/ABB/Sahinder |
| 21 | S&F (in replacement) of sheet metal enclosure distribution board triple pole and neutral (VTPN), 4 ways AC, 415 volts, 200 Amp rated copper bus bar metal double door suitable for MCCB 125 amps as incomer and MCB SP as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete. Note:- (a) MCB shall be measured and paid seprately under respectively item. (b) Make for the DB/MCB/MCCB shall be same.Make: legrand/ABB/Sahinder |
| 22 | All as in above item but 6 ways complete all as specified & directed.Make: legrand/ABB/Sahinder/L&T |
| 23 | S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete Make: legrand/ABB/Sahinder/L&T |
| 24 | S&F MCCB 250 amps, 4 Pole, 415 volt, AC, adjustable type, with breaking capacity 36 KA suitable for load line/ VTPN DB & connection complete Make: legrand/ABB/Sahinder/L&T |
| 25 | Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning by using suitable copper lugs complete:- Make: legrand/ABB/Sahinder/L&T |
| 26 | SP 6 To 32 AMP |
| 27 | SPN 40 to 63 AMP |
| 28 | S&F (in replacement) industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB SP, AC, 230 volts of 20 Amps, 'B' curve 10 KA breaking capacity for geyser and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete Make: legrand/ABB/Sahinder/L&T |
| 29 | Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 50 sqmm 3.5 core nominal cross section complete |
| 30 | Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in soft soil & getting out including levelling of bottom surface to required level complete |
| 31 | Returning filling , including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete |
| 32 | Removing excavated material /soil from site to a distance not exc 50mtr away and depositing where directed and level not exc 1.5mtr from the starting point complete |
| 33 | Sub class ‘B bricks, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and as directed |
| 34 | Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed. |
| 35 | M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete.(Note: Earth test shall be C/O in presence of Engr-in- Charge as per latest guidelines of earthing,On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.) |
| 36 | Taking down old unsv fan of any type/size and depositing in AGE E/M store yard complete all as directed by Engr-in-Charge |
| 37 | Taking down old unsv submain wiring of any size and type complete all as specified and directed |
| 38 | Taking down old unsv DB including MCCB/ MCB any type / size complete all as specified and directed |
| 39 | Supply, install, testing and commissioning of factory made LT panel of suitable size, 415 Volts, indoor type, cubical compartmentalised vermin and water proof fabricated out of 2mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, including 400 Amps rated Aluminium bus bar for phases and neutral, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x506mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer incl taking down old one complete with following incoming/out going accessories:- INCOMING (i) MCCB 250 Amp 4 pole, 36 KA -01 NoOUTGOINGMake: L&T/ABB/Schnieder(a) MCCB 63 Amp 4 pole, 16 KA -04 Nos (b) Ampere meter (digital type), 0-400 Amps with selector switch- 01 No(c) Volt meter (digital type) 0-500 volts with selector switch- 01 No(d) Indicator lamp - One set of three,CTs 400/5 -01 Set of three.(e) Change over switch - 01 No |
| 40 | Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 300 sqmm 4 core nominal cross section complete |
| 41 | All as the description of srl item No 38 but of size 185 Sq mm |
| 42 | M&L for industrial Bus Bar junction box indoor type made out of 2 mm thick GI sheet with and Including 400 Amps copper bus bar capacity (05 Nos) and all fixing arrangments complete to accommodate the main control MCCB 4 pole of cap upto 320/400 Amps as required at site complete all as specified and directed by Enge in Charge |
| 43 | Supply and Fix MCCB 4 pole 415 Volt adjustable type of capacity 350 Amps with breaking cap 36 KA complete all as specified and directed. |
| 44 | Supply and Fix MCCB 4 pole 415 Volt adjustable type of capacity 250 Amps with breaking cap 36 KA complete all as specified and directed. |
| 45 | M & L for PVC insulated copper conductor multistranded single core 10 Sq mm FRLSH flexible ,1100 volts grade confirming to IS 694/2010 specification with latest ammendments with and including PVC conduit med grade ,accessories and all fixing arrangements complete all as reqd at site and directed by Engr in Charge. |
| 46 | M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete |
| 47 | Supply and fix electric water heater, storage type steel body with Stailess Steel inner tank and heating element upto 1.5 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes etc.including grouting of bolts for fixing complete all as specified and directed by Engr-in-charge. |
| 48 | M&L for two single core (submain) PVC insulated cable with 4.0 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4.0 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 25 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete |
| 49 | S&F sheet metal enclosure flush type, Single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB with 20 Amps complete |
| 50 | S&F MCB SP 6 to 40 amps, 240 Volts, 10 KA breaking capacity 'C' curve incl connection complete (To be fitted in existing DB) |
| 51 | Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 4.0 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed. |
| 52 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 53 | Dismentling wrought iron or mild steel work of any description not other wise provided. |
| 54 | Mild steel angle iron posts and struts, MS flat iron fillet securing chain link fencing confirming to FE-290 E-165 as in fencing including cutting tops for required shape, drilling holes,bolting, notching for wire including all necessary drilling of similar work, complete all as specified and directed. |
| 55 | Plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed. |
| 56 | Demolition of stone, brick masonry built in cement mortar incl quoins, arches, etc but exceeding ashlar facing dressed stone Work etc. |
| 57 | Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius in cement mortar 1:6 complete all as specified and directed. |
| 58 | All as per item above but except bricks. |
| 59 | M&L rendering 15 mm thick on fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth without using extra cement in CM 1:4 with water proofing compuund as per manufacture's instruction including fair finishing to top surface as directed by Engineer-in-Charge(water proofing compound will be measured and paid separately ). |
| 60 | M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse stone dust) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) white cement in place of ordinary cement to be used in the work, panels with groove all around as per approved pattern or design and colour including scrubbing and washing the tip layer with brushes and water to expose the stone chippings complete including scaffolding up to 8 floor all as specified (Payment for providing grooves shall be made separately). |
| 61 | S & F in Repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc.as directed (each line wire to be measured). |
| 62 | Restraining & resecuring existing barbed wire of any type incl making good staples etc any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc (each line wire to be measured) complete all as specified. |
| 63 | S&F MS screw bolts (machine made) with hexagonal or square heads at one ends and screwed the other, or screwed both ends, each screwed end to be fitting with washer and one hexagonal or square nut n.exc. 5cm long and dia of shank 8 to 10 mm etc. |
| 64 | M&L, preparation of new surface, priming with red oxide / zinc chromate and two coats of synthetic enamel (ordinary tint) painting to steel and iron surface of any description over 10cm in width or girth not otherwise described. |
| 65 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed. |
| 66 | Preparing old decorated/plastered or un-plastered surfaces of walls by scrapping the surfaces and steel wire brushing down smoke soot,mould,mass and efflorescence salts and trading oil and greasy spots etc and applying one coat of Acrylic exterior emulsin paint complete all as specified and directed by Engineer-in-Charge. |
| 67 | Demolition of plain /reinforeced cement concrete for any thickness in any position and of any discription complete all as specified and as diredted |
| 68 | Providing, cement concrete Type B1,1:2:4 (using 20 mm graded aggregate) as in copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 69 | S & F Galvanised Concertina coil punched type 600mm dia, 10 m openable length (total length 90m) having 50 Nos round per 6 m lenght, dia of Core wire 2.5 mm(+/- 1mm) with tensile strength of 160Kg/Sqm, thickness of galvanised rozer blade 0.6 mm (+/- 0.5mm) of 30mm length, fixing/securing or tying in position over existing barbed bire and Y shaped angel iron in to 3.0 m ht of wall incl provn of MS wire stapples or steel pins etc, in dismantling of old concertina coil complete all as specified and directed.(Note : Y shaped angle iron and barbed wire shall be measure and paid seperately) |
| 70 | M & L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with providing 15mm thick screed bed in cement mortar 1:4. Please Enable Macros to View BoQ information |