| 1 | M&L for MS pipeline modification from Collection Tank to Bar Screen includingsupports, valves/fittings suitable for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 2 | M&L for Equalization pump replacement (duty as per existing) including base, coupling, alignment & trial run suitable for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 3 | M&L for Equalization pump suction/discharge line modification NRV/ union /flange/ fittings suitable for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 4 | M&L for Bar screen chamber (MS), internal cleaning, FRP lining/coating inside (lamination) including curing & touch-up suitable for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 5 | M&L for replace screen and supply & install new SS bar screen (manual type) with frame & fixing suitable for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 6 | M&L for Servicing of all existing pumps including bearing/seal check, alignment & trial run for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 7 | M&L for Servicing of 2 blowers (mechanical+ electrical) including trial run for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 8 | M&L for replace/upgrade diffuser system (fine/coarse bubble as per existing) including clamps and air header modifications suitable for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 9 | M&L for service existing panel board (cleaning, tightening, testing, replace minor components as required) for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 10 | M&L for Cleaning/desilting of all RCC tanks (EQ/MBBR/Tube Settler/Filter Feed Tank/others) including Disposal with in plant for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 11 | supply & filling MBBR bio media (adjust qty as per requirement) suitable for STP of capacity 300KLD including taking out and disposed off old media complete all as specified and as directed by the Engineer-In-Charge. |
| 12 | M&L for replace Tube Settler media: remove old modules, supply new PVC tube packs, install & sealing for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 13 | M&L for sludge transfer pump repairs & installation (duty as per existing) for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 14 | M&L for Sludge pipe line modification/ renewal from settler/clarifier to sludge tank/press for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 15 | M&L for MS sludge holding tank fabrication & supply (manhole, vent, drain, ladder, painting), installation for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 16 | M&L for screw pump for filter press feed (1W+1SB) for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 17 | M&L for Filter Press (2 Nos: 1W+1SB) including hydraulic pack, plates, piping upto outlet for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 18 | M&L for Polymer dosing system : HDPE make uptank, agitator, dosing pump, calibration column for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 19 | M&L for Feed pumps (1W+1SB) for filtration/ transfer including installation for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 20 | M&L for MGF (MS) fabrication & supply with internals, manifolds, media, painting, installation for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 21 | M&L for ACF (MS) fabrication & supply with internals, manifolds, media, painting for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 22 | M&L for Chlorine dosing: HDPE tank, dosing pumps (1W+1SB) installation for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 23 | M&L for separate panel for installed pumps/press/dosing (MCC with protections, wiring, testing) for STP of capacity 300KLD complete all as specified and as directed by the Engineer-In-Charge. |
| 24 | Supplying, fixing, commissioning and testing surface, self priming, three phase, coupled pump with motor mono block pumping set of 2HP with all fixing arrangement like base frame, PCC platform, electrically driven, 415 Volts, three phase, AC, size 65x50 mm, speed 2800 RPM, 50 Hz, cast iron fabricated, protection class IP-55, impeller dia 224 MM, insulation class 'F' having a discharge flow rate 4 to 9.4 LPS at a head of 11 to 16 Meters, delivery/discharge dia 50 mm including insertion of GI/ERW column pipe with other connected accessories and necessary electrical connections complete all as specified and as directed. |
| 25 | Supply and laying GI tubing 40mm bore medium grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables including taking out old tube complete all as specified and as directed. |
| 26 | Supply and laying GI tubing 25mm bore medium grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables including taking out old tube complete all as specified and as directed. |
| 27 | Supply and laying GI tubing 15mm bore medium grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables including taking out old tube complete all as specified and as directed. |
| 28 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 29 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 30 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 31 | M & L for PCC 1:4:8 Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete including demolition of old concrete complete all as specified and as directed. |
| 32 | S&F in repairs, stop valves, 40mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed. |
| 33 | S&F in repairs, stop valves, 15mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed. Please Enable Macros to View BoQ information |