| 1 | Demolition of brick work built in cement morter including all quoins, arches, pillars etc, complete all as specified and directed. |
| 2 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed. |
| 3 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 but except bricks complete all as specified and directed. Note :- Old serviceable bricks retrived from demolition shall be re-used under this item after cleaning. |
| 4 | Taking down cement plaster of any description on brick or stone wall/ceiling etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 5 | M&L for 15mm thick rendering on Brick masonary wall surfaces in CM 1:4 mixed with water proofing compound finised even and smooth with using extra cement complete all as specified and directed. Note :- Water proofing compound shall be mixed as per manufacturers instruction & shall be measured & paid seprately. |
| 6 | Supply only integral water proofing compound complete all as specified and directed. |
| 7 | M&L in repair 150mm Ultra PEDWC (Double wall corrugated) pipe and all necessary fittings and fixtures complete incl hunching sides of pipe with cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) complete all as specified and directed. |
| 8 | M & L PCC ( 1 : 4 : 8 ) Type D-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 9 | Demolition of PCC of any description and in any position not otherwise specifically provided for drain etc including removing the same where directed complete all as specified and directed. |
| 10 | Demolition of reinforced cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level) reinforced complete all as specified and directed. |
| 11 | M & L for precast RCC 1:2:4 type B-1(using 20mm graded stone aggregate)for manhole cover including placing and set in CM 1:6 complete all as specified and directed. |
| 12 | M & L mild steel deformed or twisted bar(TMT bar)8 to10mm dia and cover cut to length bent to shape reqd, incl, cranking benching spirally for copying for columns hooking ends and bending with and including MS wire annealed wire not less than 0.9 mm dia complete all as specified and directed. |
| 13 | M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggragate) as in bed blocks, coping etc including weathering slightly rounded or chamfered angles and throating making groves for fixing of man hole cover including necessary form work complete all as specified and directed. |
| 14 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including finishing the top of benching even and smooth using extra cement (forming channel shall be measured and paid for separately) complete all as specified and directed. |
| 15 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm pipe complete all as specified and directed. |
| 16 | M& L preparing plastered new surfaces of wall and applying three coats of white wash on wall surface complete all as specified and directed. |
| 17 | Excavating in post holes soft/loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 18 | S&F Mild Steel angle iron posts and struts in fencing including cutting tops to shapes as directed including driling holes for bolting of MS flat iron in horizontal, vertical & diagonal faces of each panel to be intertwined with Chain link fencing, and fixed to posts with MS nut, bolts and washers including all necessary drilling bolting etc, and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed. |
| 19 | M & L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 20 | S&F Galvanised. medium zinc coating 135-150 GSM as per IS-278-2003 , 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) Note : In every 1 to 3 mtr original manufacturer logo printed barbed wire and material test certificate and authentication should be provided by manufacturing company. |
| 21 | Supply only galvanized medium zinc coating 135-150 GSM as per IS-2721-2003 chain link fencing , complete all as specified and directed. Note: In every 1 to 3 mtr original manufacturer logo printed Chain link fencing wire and material test certificate and authentication should be provided by manufacturing company. |
| 22 | Fixing only chain link fencing including line bars, any mesh, size and type to any type of standard, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 23 | S&F mild steel bolts. purpose made.with hexagonal orsquare head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut. exc 10 cm but not exc 15 cm and 12mm dia complete all as specified and directed. |
| 24 | Supply only Mild steel bars 10mm dia round bar complete all as specified and directed. |
| 25 | M&L for preparation of new or previously untreated steel surfaces of any description exceeding 10cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 26 | M& L preparing plastered Old surfaces of walls applying two coats of white wash complete all as specified & directed. |
| 27 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons laid and pointed in any mortor etc. complete all as specified and directed. |
| 28 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand all as specified |
| 29 | To attend and rectify sewage complaint by 2 sewage cleaners such as blockage/ choked bathroom / WHB /WC drainage and also outlet PVC/CI pipe and making functional Ist man hole sewage line etc complete all as specified and directed and directed any type any time between 9.00 AM to 5 PM excluding sunday & closed holiday all as specified and directed. Note :- They will report daily to complant cell at 0830 hrs daily except sunday & closed holiday. Contractor or his representative collect the complants at 09.00 hrs from compliant cell of SDO BABUGARH and the complaints will be attended/make good/rectified with in 24 hrs on receipt of the complaints and info the status of the compaintd at 1700 hrs every day to complaint cell. On failure of the same a panelty of Rs 50/- per day per compaints will be charged. |
| 30 | Cleaning of manholes and septic tanks by taking out complete sludge water, solids, brick bats, polythene silt etc complete by manualy or mechanically by HCV mounted suction discharge machine, removing/disposing the entire retrieved material outside periphery of defence land including taking off manholes cover and re-fixing the same after cleaning complete all as specifed and directed. |
| 31 | Dewatering of soak well completely of n.exc 3 mtr dia and n.exc 6 mtr depth by means of pumping out to out side of defence land complete all as specified and directed. |
| 32 | Cleaning and maint of sewage line of size 150mm dia and 1-6 mtr depth manholes in the following steps:- (i) Dewatering of manholes (ii) Removing of all sludge/waste material from all manholes, desilting of floor, lean the floor and walls of the manhole after removing complete sludge/materials with clean water (iii). Removing the temprary blockage of inlet/outlet pipe and making functional the manholes. (iv) Remove all taken out sludge/ waste materials in covered containers out side the Defence Land. any means and getting out and removing sludge to a distance up to 3 km out side of defence land limit and disposal in low lying area and incl removing of all types of blockage of any length between two consecutive deep manholes and to keep smooth functoining without any blockage in any situation by mechanical means with manual and mechanical process incl removel and refixing of man hole covers complete all as spefied and directed. |
| 33 | Excavation in trenches in soft/loose soil n. exc 1.5 m wide & n. exc 1.5 m in depth for foundations for shafts, wells cesspits, manholes, pier holes & getting out complete all as specifed and directed. |
| 34 | Returning, filling in layer including leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 35 | Removing surplus spoil to a distance exceeding 250 m and n. exc 500m & depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 36 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out concrete embedded portion and making good disturbed ground complete all as specified and directed. |
| 37 | Dismantling fencing wire mesh any type alla complete all as specified and directed. Please Enable Macros to View BoQ information |