| 1 | Material and labour for point wiring concealed type with PVC insulated, unsheathed, single core multistranded copper conductor cable ISI marked (FRLSH) of size 2.5 Sqmm, 1100 volts grade including 2.5 Sqmm PVC insulated, unsheathed, copper conductor cable ISI marked for earth continuity wire to be drawn through in and including suitable size PVC conduit medium grade ISI marked with its accessories & new pressed steel terminal boxes, cover frame and brass screws with cup washers suitable for modular type fittings for fixing of modular switches / sockets / regulators etc. including all necessary wall cutting chases and making good disturbed surfaces in cement mortar 1:3 for One socket outlet 16 Amps independent board complete all as per IS specification as specified and as directed.NOTE :- New pressed steel terminal boxes, cover frame and brass screws with cup washers suitable for modular type fittings shall be measured and paid for separately as per relevant item of GI box suitable for modular switch sockets and modular cover plate with frame suitable for modular switch sockets |
| 2 | All as per Item No. 1.00 above but One 3 pin socket out let 15 Amps on independent board point. |
| 3 | Material and labour for modular socket outlet 6A/16A, 2/3 pin combined 2 module complete all as specified and as directed. |
| 4 | Material and labour for modular switch 1 way 15/16 Amps 1 module, suitable for 230 Volts Ac supply complete all as specified and as directed. |
| 5 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece with thermal cutoff suitable for AC supply, 50 HZ complete and 02 Nos angle valve complete all as specified and directed. |
| 6 | Supply and fix following size GI tubing medium grade size 15 mm with all fitting and fixed complete to walls and ceiling or laid in floors of size including all accessories such as tee,bend,elbow,and union etc taking down the existing pipes and connections including making good to disturbed surface of wall and match with the existing one (ISI marked) complete all as specified and directed. |
| 7 | Supply and fixing in replacement PVC connection 15 mm bore , 600 mm long with brass ends terminals suitable for Geyser complete all as specified and as directed. |
| 8 | Supply and fixing Bib tap of size 15 mm, cast copper Alloy with clutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 9 | Supply & installation of 15 high mast shaft in two section suitbale for 55 m/sec wind speed along with head frame, luminiaries carriage suitable for 12 LED 200 watt luminiaries in symmetrical arrangement and other accesories manufactured in factory with raising lowering system comprising double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightining finial, (Wiring material from JB to individual luminiare & MCB in base compartment are not included and are a part of installation), with supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template and outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminiaries, power tool control with 2 No 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5sq. mm terminals. 16M High mast of BAJAJ Make or equivalent in GE, Crompton, Philips, Havells. |
| 10 | HIGH MAST SYSTEMMAKE : Bajaj Electricals Ltd or techno commercially equivalentHeight of mast : 15 MeterNo. of Section : TwoMaterial Construction : S355 Grade as per BS-EN10 025Base dia and top diameter (A/F) : Top : 150mm Botton : 460 mmCross section of Mast : 20 side polygonStandard for Galvanisation : A per BS EN ISO 1461Size of Opening and door at base : 1200 x 250 mmDiameter of base plate : 670 mmThickness of base plate : 25 mmLighting protection finial : GI single spike of length 1200mmMax. wind speed : 44m/s as per IS 875 (Part III)Number of foundation bolts : 12 NosPCD of foundation bolts : 590 mmType / diameter / length of found ation bolts : TS 600/30mm dia/ 850 mm long |
| 11 | FOUNDATION DETAILS1. Excavation dimensions 2800 x 2800 x 1500mm size2. Lean Concrete 100 mm thick ( 1: 4: 8) D2 (using 40mm graded Aggregate)3. Matt bars 12mm dia TMT Bars @ 200C/C both ways in double layers4. RCC (1: 1.5 : 3) 2600 X 2600 X300MM as in footing5. RCC (1 : 1.5 : 3) 1000 X 1000 X 1400 MM (1100MM below GL and 300 mm above GL)6. 8 Nos 16mm dia TMT Bars 4 at corners 4 at centres of pedastal col as main bar with 600mm long craking at bottom over matt bars7. 16 Nos 12mm dia TMT main bars (4 Nos each at 4 side with 600mm long cranking at bottom over matt bars.8. 10mm dia TMT bars @ 150mm C/C as Stirrups9. 300mm dia 850mm long foundation bolts 08 Nos inserted in to 16 mm thick anchoring plate 590mm dia at bottom with pointed galvanised nut one each at bottom and top of plate.10. Foundaiton bolt min clearance 150mm above pedestal col to rest high mast base plate 25mm thick over the bolts. Galvanished nuts 01 number at bottom of base plate 2 Nos at top of base plate. Note : The unit rate is inclusive of necessary formwork, RFR removal of surplus earth, external finishes and other unforeseen items all as directed by Engr - in- Charge |
| 12 | LUMINAIRES CARRIAGEMaterial of construction : 50 NB ERW Class B-M.S PipeDiameter of carriage ring (mm) : 535 mm (ID)Construction : 06 Arm, Welded, 2 SectionsLoad carrying capacity : 08 LuminaireTRAILING CABLEConductor : Copper, 5 core, 2.5 SqmmInsulation : EPR insulated PCP scheathedNo.of circuits per mast : One |
| 13 | WINCH / POWDER TOOLType /SWL of winch : Double drum, SWL 750 Kg - SGDDMethod of Operation : Integral MotorMotor Capacity : 1.0 HP ( Including suitable starter)No of Speeds : 6 Pole, Single speedTorque Limitor : With Mechanical Tripping FacilitySTAINLESS STEEL WIRE ROPEGrade / construction : AISI 316, 7/19 ConstructionNumber of Ropes : Two ContinuousDiameter (mm) : 6 mmBreaking load Capacity : 2350 Kg x 2 |
| 14 | Supply and fixing Bajaj amaze 200w LED flood light , Matt black polyester powder coated with secondary lens optics with LED make lumiled having luminaire efficacy of 130 lm/W. Total of 26,000 Lums +/- 10%. Provided with built in surge protection 5kv and external surge protection of 10kv, having Ingress protection IP66 complete all as specified and directed. Make:- Bajaj amaze- BJFL 200w LED-112984 or techno commercially equivalent in other makes as per PS. |
| 15 | Supply laying & testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 Volt graded size 3.5 core 35 Sqmm complete all as specified and directed. |
| 16 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard soil/dense soil/road/pathway/concrete etc complete all as specified and directed. |
| 17 | Returning , filing including spreading, leveling and well ramming Cum in layers not exc 25 CM thick in any type complete all as specified and directed. |
| 18 | Removing excavated material not exc 50 mtr distance and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 19 | M & L for sand cushioning using dry sand 8 cm thick before and 15 cm thick after laying of under ground cable complete all as specified and directed. |
| 20 | Supply and lay cable cover LV type flate size 250 X 150 X 40 mm complete all as specified and directed. |
| 21 | Suppply, installed test and commissioning of LT panel board made out of 3.15mm thick CRCA sheet out door type front and rear opening totally enclosed dust,weather and vermin proof(minimum depth of panel should be 40cm) having Aluninium buss bar of capacity 200 Amp and half for neutral for connecting the LT underground cable 50 Sqmm 3.5 core run (01 run for incoming and 02 run of going) Ac 50 HZ RYB N insulated with insulator complete with Volt meter, Ammeter including CT ratio, selector Switches, Indicator Lamps, internal wiring including powder coated cabinets for housing of MCCB FP 63 AMP Amp=01, as incomer & MCCB FP 50, TP 40,&,16-(1,1) as out going, mounted on angle iron frame of 50 X 50 X 6mm duly grouted in ground with cable glands for each incoming & out going cable. |
| 22 | Supply and Fixing MCCB TP 63 amp 415 volt 50HZ AC supply 36 KA complete all as specified and as directed. |
| 23 | Supply and Fixing MCB TP 25 to 63 amp 415 volt 50HZ AC supply 36 KA complete all as specified and as directed. |
| 24 | Supply and fixingMCCB TP 63 to 100 amp 415 volt 50HZ AC supply 36 KA complete all as specified and as directed. |
| 25 | Earthing for poles & other machinery/equipment using 4 mm GI wire as earthing lead and MS galvanized plate of size 60 cm x 60 cm x 6 mm, as earth electrode complete all as specified and as directed. |
| 26 | Supply and fixing 80mm dia GI pipe light grade for protecting cable over road crossing complete all as specified and as directed. |
| 27 | Supply and fixing Hot dipped GI Octagonal pole of 9 meter long with 01 meter arms suitable for mounting of 02 Nos (double arms) of LED street light complete with base plate and GI foundation bolts and nuts including excavation and foundation complete all as specified and directed.Make:- Crompton or Equivalent as approved by GE |
| 28 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed. |
| 29 | Supply and fixing LED street light fitting 01x 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and directed. |
| 30 | Supply and fixing in replacement FRLS PVC insulated copper conductor of Size 2.5 Sqmm 3 core with cable thimble/ Lux made of copper in surface/ recessed as required for Poles/ LT panesl/ Looping box etc with necessary connections including PVC conduite 25 mm Complete all as specified and directed. Please Enable Macros to View BoQ information |