| 1 | CIVIL WORKExcavation in all kinds of soil with hydraulic excavator (1 cum capacity) including cutting and loading in tippers, trimming bottom and side slopes ,in accordance with requirements of lines,grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m.work complete as directed by the Engineer-in-charge. Football field |
| 2 | Atheltic track |
| 3 | Volleyball court |
| 4 | Kho kho,Kabadi court |
| 5 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as directed by the Engineer-in-charge. Football field |
| 6 | Atheltic track |
| 7 | Volleyball court |
| 8 | Kho kho,Kabadi court |
| 9 | Internal road and pathwaya |
| 10 | Approch road |
| 11 | Pathway Football field peripherial |
| 12 | Supplying and fixing of needle-punched staple fiber non-woven geotextile fabric under the fabric formed mattress, conforming to the following specifications:Minimum mass: 200GSM (MARV – Mean Average Roll Value), Minimum thickness: 0.75 mm Grab tensile strength: 700 N as per ASTM D 4632 Grab elongation: 50% as per ASTM D 4632 Trapezoidal tear strength: > 250 N as per ASTM D 4533 CBR puncture resistance: > 1800 N as per ASTM D 6241 Minimum wide width tensile strength: 12 kN/m. The geotextile shall be needle-punched staple fiber non-woven type, suitable for separation, filtration, and protection applications, and shall be installed as per detailed site requirements and technical specifications, including proper surface preparation, laying, jointing, and anchoring as per directed by the Engineer-in-charge. make- GEOQUEST,SOLMAX. |
| 13 | Providing, laying, spreading and compacting graded stone aggregate to laying in uniform layers in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density etc.including cost of all labour, material, conveyance, loading and unloading,machinery charges all complete as per the direction of Engineer-in-charge. Football field |
| 14 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (5th Revision) etc complete as per direction of Engineer-in-charge. Atheltic track |
| 15 | Volleyball court |
| 16 | Kho kho,Kabadi court |
| 17 | Internal road and pathwaya |
| 18 | Approch road |
| 19 | Pathway Football field peripherial |
| 20 | Supplying , stacking and spreading of good earth at site within initial lead including royalty and carriage transporting to site, spreading, grading to required slope and compacting to meet requirement. Football field |
| 21 | Atheltic track |
| 22 | Volleyball court |
| 23 | Kho kho,Kabadi court |
| 24 | Supplying , stacking and spreading of root zone sand as per USGA standard at site including royalty and carriage and Laying of root zone sand on the top of aggragate as per desired level.Football field |
| 25 | Supply and laying of labour and material for Base preparation of grassing and fertilizer apllication in the required proportion specified or directed by the Officer-in-charge.Football field |
| 26 | Supply & Planting Bermuda grass on site by Planting method directed by engineer in charge. The grass must be weed fee. Rate including all required fertilizer, pesticider & Chemical etc. complete for growing the turf. Spec. No.:- As directed by Engineer in charge. (Including cost of 6 month of Maintenance of football Ground) Football field |
| 27 | Supplying, stacking, laying and compaction of a consolidated layer, 50 mm thick, of graded material of 4.75 mm to 2.36 mm mixed with cohesive material for stability and grip, etc., as per the direction of the engineer-in-charge.Atheltic track |
| 28 | Volleyball court |
| 29 | Kho kho,Kabadi court |
| 30 | Providing and laying in trenches DWC perforated pipe@ 100mm dia conforming to IS 16098 (Part-2) with all fitting accessories and jointing, including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately).The cost inclusive of labour,material,fitting and fixing,conveyance,loading and unloading etc all complete as per the direction of Engineer-in-charge. |
| 31 | Providing and laying in trenches DWC non perforated pipe@ 110mm dia conforming to IS 16098 (Part-2) with all fitting accessories and jointing, including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately).The cost inclusive of labour,material,fitting and fixing, conveyance, loading and unloading etc all complete as per the direction of Engineer-in-charge. |
| 32 | Providing and laying in trenches DWC non perforated pipe@ 160mm dia conforming to IS 16098 (Part-2) with all fitting accessories and jointing, including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately).The cost inclusive of labour,material,fitting and fixing, conveyance, loading and unloading etc all complete as per the direction of Engineer-in-charge. |
| 33 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. Volleyball court |
| 34 | Kho kho,Kabadi court |
| 35 | Internal road and pathwaya |
| 36 | Approch road |
| 37 | Earth work in excavation of foundation trenches in all kind of soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge. Indoor hall |
| 38 | Facility centre |
| 39 | Internal road and pathwaya |
| 40 | Security room and Gate complex |
| 41 | Drainage |
| 42 | Approch road |
| 43 | Drainage peripherial |
| 44 | Pathway Football field peripherial |
| 45 | Land development and surface filling |
| 46 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge.Indoor hall |
| 47 | Facility centre |
| 48 | Internal road and pathwaya |
| 49 | Security room and Gate complex |
| 50 | Drainage |
| 51 | Approch road |
| 52 | Drainage peripherial |
| 53 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. Indoor hall |
| 54 | Facility centre |
| 55 | Internal road and pathwaya |
| 56 | Security room and Gate complex |
| 57 | Approch road |
| 58 | Land development and surface filling |
| 59 | Pathway Football field peripherial |
| 60 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.(make-premise-BAYER,Paxton-FMC,ozie-KALYANI). Indoor hall |
| 61 | Facility centre |
| 62 | Security room and Gate complex |
| 63 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.Indoor hall |
| 64 | Facility centre |
| 65 | Internal road and pathwaya |
| 66 | Security room and Gate complex |
| 67 | Drainage |
| 68 | Drainage peripherial |
| 69 | Pathway Football field peripherial |
| 70 | Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge.Indoor hall |
| 71 | Facility centre |
| 72 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Indoor hall |
| 73 | Facility centre |
| 74 | Security room and Gate complex |
| 75 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Indoor hallGround floor |
| 76 | First floor |
| 77 | Second floor |
| 78 | Facility centre-Ground floor |
| 79 | Security room and Gate complex |
| 80 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Indoor hall-Ground floor |
| 81 | Facility centre-Ground floor |
| 82 | Security room and Gate complex |
| 83 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.Indoor hall-Footing |
| 84 | Pedestal |
| 85 | Column upto plinth |
| 86 | Plinth beam |
| 87 | Column |
| 88 | Lintel |
| 89 | Roof Beam |
| 90 | Roof Slab |
| 91 | Stair case |
| 92 | Facility centreFooting |
| 93 | Pedestal |
| 94 | Column upto plinth |
| 95 | Plinth beam |
| 96 | Column |
| 97 | Lintel |
| 98 | Roof Beam |
| 99 | Roof Slab |
| 100 | Security room and Gate complex Footing |
| 101 | Column upto plinth |
| 102 | Plinth beam |
| 103 | Column |
| 104 | Lintel |
| 105 | Roof Beam |
| 106 | Roof Slab |
| 107 | Drainage Foundation |
| 108 | RCC wall |
| 109 | Drainage peripherialFoundation |
| 110 | RCC wall |
| 111 | First floor Indoor hall column |
| 112 | Roof Beam |
| 113 | Lintel |
| 114 | Roof Slab |
| 115 | Second floorIndoor hallcolumn |
| 116 | Roof Beam |
| 117 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.Ground floor Indoor hall |
| 118 | Facility centre |
| 119 | Security room and Gate complex |
| 120 | Drainage |
| 121 | Drainage peripherial |
| 122 | First floor Indoor hall |
| 123 | Second floor Indoor hall |
| 124 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Ground floorIndoor hall |
| 125 | Facility centre |
| 126 | Security room and Gate complex |
| 127 | First floor Indoor hall |
| 128 | Second floorIndoor hall |
| 129 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Ground floorIndoor hall |
| 130 | Facility centre |
| 131 | Security room and Gate complex |
| 132 | First floor Indoor hall |
| 133 | Second floor Indoor hall |
| 134 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Ground floorIndoor hall |
| 135 | Facility centre |
| 136 | Security room and Gate complex |
| 137 | First floorIndoor hall |
| 138 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.Indoor hall |
| 139 | Facility centre |
| 140 | Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.Indoor hall |
| 141 | Facility centre |
| 142 | Providing full body matt finish vitrified tile flooring using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 600x600 of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.Indoor hall |
| 143 | Facility centre |
| 144 | Security room and Gate complex |
| 145 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm homogeneous coloured/ printed series of approved make (JOHNSON / SOMANY/ KAJARIA/ RAK) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects.Indoor hall |
| 146 | Facility centre |
| 147 | Fixing of Ceramic wall tiles of premium grade having thickness 6.50mm to 7.00mm confirming to IS 13753 of size 60cm x 30cm special plain / printed series in dados skirting & riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.(make-Somany, Johnson, RAK, Kajaria) Security room and Gate complex |
| 148 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge.Indoor hall |
| 149 | Facility centre |
| 150 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in Dado over 12mm thick bed of cement mortar 1:3 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance & royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge.Indoor hall |
| 151 | Facility centre |
| 152 | Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness 8mm to 10mm of size 300mm x 300mm confirming to IS 4457 with colour / printed series of approved make (JOHNSON /RAK / SOMANY/ KAJARIA ) on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T&P etc. required for the work in all respect as directed by the Engineer in charge.Indoor hall |
| 153 | Facility centre |
| 154 | 25 mm. average thick artificial stone flooring with cement punning laid to proper slope with cement concrete of proportion (1:2:4) using screened and washed sharp sand for mortar with black hard crusher broken granite stone chips of approved quality and from approved quarry, washed and cleaned laid in two layers i.e. the bottom layer being 19 mm . thick and top layer of 6mm. thick with 12mm. to 20. size black hard crusher broken stone chips (20mm size chips not to exceed 25%) including chipping and chiseling and cleaning the top surface of the floor slabs in upper floors, including rounding of corners, watering and curing with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge.Indoor hall |
| 155 | Supply & installation of Sports Vinyl Flooring of 7 mm thickness EN428. Anti Virus, Anti Bacterial, Heavy Metal Free, Phthalate Free. Weight 4350 G/Sq. Mtr EN430. Impact Sound Insulation 20 - 22 EN ISO 717-2 & EN ISO 140 - 8, Flammability class CFL - S1 EN13501 - 1, VOC Indoor Air Quality Floorscore Certified ( SCS - FS - 04547), Impact Resistance >8 N.m EN1517, Shock Absorption 16% - 20% EN14808, Spectular Gloss <30 EN2813, Abrasion resistant (H 18 Wheel) <1000 Mg / 1000 Cycles EN ISO 5470-1. Colour - Blue including cost, conveyance, loading, unloading of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.Make - Responsive, Gerfloor, Mondo.Indoor hall |
| 156 | Supply & Installation of 6 mm thickness EVA foam called \\" EVA Foam SOFT\\". The is specially designed to provide cushioning system over the Concrete Badminton Arena. Suitable for Indooe Use, The mat is Precise, flexible, closed cell Non-Absorbent nature for any kind of liquid & has a smooth Finish. This cushioning System is denser and soft, Ultra light weight, highly formale with high density of 140 Kg/ Cubic Meter with a shore hardnedd of 40 - 45. It has a smooth texture on both sides, is easy to cut, shape & Paste with Adhesive. It is excellent for heat forming and scoring. The cushioning needs to be pasted on the concrete base with Adhesive & Heat Technology before laying the PVC Vinyl Sports Flooring.Indoor hall |
| 157 | Supply & Installation of 4.5 mm Sports PVC Flooring Mat for Play off Area/ Margin, EN428 Heavy Metal Free, Phthalate Free. Weight 3350 G/Sq. Mtr EN430. Impact Sound Insulation 20 - 22 EN ISO 717-2 & EN ISO 140 - 8, Flammability class CFL - S1 EN13501 - 1, VOC Indoor Air Quality Floorscore Certified ( SCS - FS - 04547), Impact Resistance >8 N.m EN1517, Shock Absorption 16% - 20% EN14808, Spectular Gloss <30 EN2813, Abrasion resistant (H 18 Wheel) <1000 Mg / 1000 Cycles EN ISO 5470-1. Colour - Green Make - Responsive, Armstrong, Mondo. Indoor hall |
| 158 | Supply & Installation of BWF Certified PVC Badminton Court Mat of 4.5mm thickness for playing area, Size Size 15.4m X 7.1m, EN/DN Tested (EN 14904: Shock Absorption>= 11%, Vertical Deformation or DIN 18032.2:Force Reduction>=11%,Standard Deformation) to be glued /taped on top of the mat, including line marking. The cost includes all materials, labour, conveyance, taxes, loading, unloading, T&P, etc. Complete as per drawing and as per relevant specification including the followings and asper the direction of the Engineer-in-charge. (Mat Colour -Green for Playing area) Must be approved by BWF. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-incharge.Brand : Yonex, Gerfloor, Mondo.Indoor hall |
| 159 | Providing & Fixinng factory made 100% Solid WPC ( Wood Polymer Composite )- Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comparising of virgin PVC polymer of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of ( Min. 990 N ),Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght, , all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company. (Make-Green Land / Century/ Alstone) Indoor hall |
| 160 | Facility centre |
| 161 | Security room and Gate complex |
| 162 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.Indoor hall |
| 163 | Facility centre |
| 164 | Security room and Gate complex |
| 165 | Supplying and fixing of Powder coated 50-60 microns approved colour of Aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 12mm clear toughened glass of make-Saint gobain/AIS/Gardian/modi. the rate quoted inclusive of hardwares like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion ,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm glass felt along with all accessories etc complete. the gap between the wall and window will be filled with silicon weather sealant in the outer side. Casement Door Outer frame - 40mm x 45.3mm Series x 1.4mm thickness, Fly mullion - 44 x 60 mm x 1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness, Transom - 40.28 x 125.8 x 1.75 mm thickness, Bottom adopter - 34.6 x 26 x 1.5mm thickness, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Jindal,Hindalco,schueco). Facility centre |
| 166 | Metal Door Providing and fixing ISI Marked un-insulated fire rated door confirming to IS 3614:2021,& tested to IS17518,and shall carry a unique label with certification/test report number.The fire rating shall be for 120minutes integrity only.Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2(18 SWG) for both frame and shutter, G.I. sheet (zinc coating 120 gsm/sqm).Frame shall be 125 x 55 grooved profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 46mm thick with required fire rating and with vision panel. The infill material shall be resin bonded honeycomb core. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers.The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 150 x 750mm (max 0.12sq.mt) on both shutters, fixing with clipon arrangement. |
| 167 | All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge. Cost of double leaf doorset shall include following hardware and accessories as a complete assembly. SS ball bearing hinges of SS-304 grade of size100x75x3mm,1no Fire rated mortise dead lock, 55mm BS, 20mm sq. forend, including escutheion, sss as per EN 12209 with both side key cylinder on active leaf and 2nos flush bolt on the inactive leaf in case of double leaf door along with dust proof socket at bottom, 1pairs Pull handle D type, 22dia, CTC 300mm, back to back per leaf, with spindle,SS 304, SS finish. 1no of Door closer with spring size of EN 2- 4, as per EN1154 and CE marked per leaf. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation.Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a un-latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report. for more info refer doors details drawings, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Shakti Hormannm,Tata pravesh). Indoor hall |
| 168 | Supplying and installing UPVC- 3 track 3 shutter sliding windows with Outer dimension - 104 x 49 sash dimension of 61mm x 39mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 5mm reflective toughened glass . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge.(Make-(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance). Indoor hall |
| 169 | Facility centre |
| 170 | Security room and Gate complex |
| 171 | Supplying and installing uPVC- Ventilator windows having section of 55 mm x 50 mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 1.5 mm. The outer will be fitted with 3.5mm pinhead glass . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge. (Make- (Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance). Indoor hall |
| 172 | Facility centre |
| 173 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. Indoor hall |
| 174 | Facility centre |
| 175 | Security room and Gate complex |
| 176 | First floor Indoor hall |
| 177 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Ground floor Indoor hall |
| 178 | Facility centre |
| 179 | Security room and Gate complex |
| 180 | First floor Indoor hall |
| 181 | Second floorIndoor hall |
| 182 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Ground floor Indoor hall |
| 183 | Facility centre |
| 184 | Security room and Gate complex |
| 185 | First floorIndoor hall |
| 186 | Second floorIndoor hall |
| 187 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground floor Indoor hall |
| 188 | Facility centre |
| 189 | Security room and Gate complex |
| 190 | First floorIndoor hall |
| 191 | Second floorIndoor hall |
| 192 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Ground floor Indoor hall |
| 193 | Facility centre |
| 194 | Security room and Gate complex |
| 195 | First floorIndoor hall |
| 196 | Second floorIndoor hall |
| 197 | Painting two coat with approved synthetic enamel paint to new wood work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Ground floor Indoor hall |
| 198 | Facility centre |
| 199 | Security room and Gate complex |
| 200 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). Indoor hall |
| 201 | Facility centre |
| 202 | Security room and Gate complex |
| 203 | Internal road |
| 204 | Pathway Football field peripherial |
| 205 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL)Indoor hall |
| 206 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. First floor Indoor hall |
| 207 | Facility centre |
| 208 | Waterproofing application:- Providing and application of two component polymer modified flexible cementitious waterproofing coating at a thickness of 1.5 -2.5 mm The membrane should have Elongation equal or more than: 30% Crack Bridging ability : Up to 1 mmAdhesive strength: 1.0 N/mm² @ 28dTensile elongation: 60% @ 20°CShore A Hardness >85 (between 3 - 7 days)etc. as per direction of E.I.C (For longer span, in terrace panel of 4m*4m should be done by groove cutting, and filling with PU Sealant)(make-Myk,Fosroc,Sika). Indoor hall |
| 209 | Facility centre |
| 210 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 6 mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. Indoor hall |
| 211 | Facility centre |
| 212 | Security room and Gate complex |
| 213 | Steel Work in built up Tubular (round,square or rectangular hollow tubes etc.)trusses etc. including cutting ,hoisting ,fixing in position and applying a priming coat of approved steel primer,including welding and bolted with special shaped washers etc.complete. Indoor hall |
| 214 | INSULATED SKIN ROOF SYSTEM:Supply and fixing of KALZIP “SELF SUPPORTED” SECRET FIX STANDING ROOFING SYSTEM IN 0.9mm THICK AA 3004/3005 ALUMINIUM ALLOY. The general roof-construction shall comprise from bottom to top: Top layer – Kalzip 65/400 Straight/ curved profile sheeting manufactured from aluminum self-supported standing seam roof system from aluminum alloy AA 3004/3005 H46 (AlMn1Mg1) as specified in BS EN 1396: 2015 material thickness of 0.9mm and in finish of Pvdf consisting of anti-corrosive primer of 5 microns, topcoat of PVDF in 20 +/-2 microns with the Total coating thickness as 25 Microns. The coil for the top panel shall have 75 microns transparent protective guard film with the roofing manufacture name printed, This Guard film prevents scratches during roll forming & handling. The standing seam sheet panel of approved make shall be fixed on to the purlin using aluminum ST clips. The head of clips shall be fixed accurately to ensure the roof sheeting expands and contracts freely during thermal movement. The material properties shall be as follows: Ultimate tensile strength minimum 200N/mm2, 0.2% Proof Stress: min 185 N/mm2, Sheets are to be laid to meet the requirements of the building geometry and fixed on aluminum clips. Clip to be fixed with SS 304 screws only. Second Layer -Insulation– One layer of Rockwool India / Roxul insulation of 50mm thickness minimum 60 kg/m³ density. Sub Girt- Top Hat and top hat bracket as required in 2.0 mm thick and 2mm thick Galvanised steel hat section to be fixed on trapezoidal Liner sheets extra. Third Layer –Vapour Control Layer– Double Sided aluminum foil. Fifth Layer – Trapezoidal Sheets Solid 30-35 /200 Galvalume steel liner 550 MPa, 0.5mm TCT 1000 mm total cover width 30-35mm deep ribs. Purlin Spacing to be advised by the roofing manufacturer and advised at 1200 mm. The panel shall be manufactured out of Hi tensile pre‐painted. Zincalume/Galvalume steel‐AZ150 (min. 150 gms/sq.mt total on both sides) having minimum yield strength of 550 MPa. The finish to the exposed surface of the liner will be polyester coating with film thickness of 15 to 20μm +/- 2 μm. Indoor hall |
| 215 | Aluminum FlashingFlashings manufactured from aluminum alloy AA 3004/3005 (AlMn1Mg1) as specified in BS EN 1396: 2015 material thickness of 0.9 mm & same finish as panel. Flashing girth to be maximum up to 578mm. Indoor hall |
| 216 | Aluminum 2mm GuttersGutters -supply and fixing of gutters as per detailed drawings consisting of and aluminum gutter of 2mm in mill finish thickness, fabricated as per the sizes required. Supply and fixing of single skin 2mm Aluminum gutter, GRADE AA1100/AA1200 ALLOY with EPDM Expansion joints for every 6.0mtr length, Down take spout of 100-250 mm at every 10mtr gutter length, & other accessories and welding at joints. The Girth of gutter shall be minimum 1200mm / as advice bythe MEP consultant. Feasibility shall be confirmed based on site conditions.. Indoor hall |
| 217 | Providing & Installation of GFRC GFRC JALI (Glass Fiber Reinforced Concrete) thickness of 25-30 mm & Border thickness of 50 mm with Pattern, design, and colour of approved make to be fixed on/between RCC /Block work Column or structural work with Dry Fixing method with appropriate SS Pipe & Cleats frame work, using fasteners, and necessary hardware etc. The element shall be made from '53 grade' Portland Cement make Birla/ 'JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass fibre make 'Owens Corning' or equivalent, Super plasticizers / Additives make by 'BASF' or equivalent, Polymers make 'BASF' or equivalent and U.V resistant Synthetic inorganic pigments shall be used for pigmentation make 'BAYFERROX (Germany)' or equivalent. The material casting shall take place in Synthetic Rubber / FRP Mould manufactured by Mould / Tool / Mould Grade Resin of Revex/ 'Reckli'.(Make-Unistone,Samudyam,Eco Vision) Indoor hall |
| 218 | Facility centre |
| 219 | Supply and Installation of System comprises of Semi unitized extruded aluminum Structural Glazing wall panels comprising of extruded Vertical Aluminium mullions and Horizontal transoms (JINDAL/HINDALCO/EQUEVALENT ) with super Durable Powder Coating finish of minimum 60 Microns confirming standards to withstand wind pressure. The mullions and transoms are installed on locations as indicated in the architectural drawings. The framing members provide no structural support for the building and the Structural Glazing wall is deemed to be a lightweight façade which is intended to separate the external from the internal of the building and provides natural light into the building. The curtain wall system is designed to have internal drainage system within the extruded sections with 6MM Blue toughened glass. Gaskets are employed as water barrier between the aluminum gridwork and the glazed sashframe, which are fully drained in the event of leakage past the primary seal. The external grooves are covered with application of backer rod with weather sealant of approved make as indicated in the concept drawing. Fabricating and supplying Mild Steel ( HDG coated ) Brackets to accommodate 3 Dimensional movement for achieving perfect verticality and proper fixing of structural glazing system with the RCC/ masonry/structural steel framework of building structure, using stainless steel (chemical/mechanical) anchor fasteners/ bolts, Teflon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel Grade 316, of the required capacity and in required numbers.Indoor hall |
| 220 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x600x50mm, reinforced with 8mm dia four nos longitudinal & 9 nos cross sectional T.M.T hoop bars, including providing 50mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50mmx1.6 mm complete, all as per direction of Engineer-in-charge. Drainage |
| 221 | Drainage peripherial |
| 222 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works (4th Revision). Internal road and pathwaya |
| 223 | Approch road |
| 224 | Providing and laying of 80mm thick factory made cement concrete interlocking Paver block of M-40 grade and approved make ,variety,colour and size made by block making machine with strong vibratory compaction of approved design and shape laid in required colour and pattern over 50 mm thick compacted bed of coarse sand filling the joint with fine sand etc.all complete including cost ,conveyance ,royalty of all materials, labour,T&P etc.Complete as per direction of all Engineer-in-charge. Internal road and pathwaya |
| 225 | Pathway Football field peripherial |
| 226 | Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. Internal road and pathwaya |
| 227 | Pathway Football field peripherial |
| 228 | Construction , Providing , Supplying and fixing the pre-cast , pre-tensioned SFRC compound wall poles having finished dimention of 2000mm x 200mm x 50mm long, (providing the construction joint at the interval of 15.4 mtr) made in M-30 grade concrete with 10 Nos of 4mm dea. HTPC ( High Tension Pre-Coated) wire, fixed in cast –in-situ PCC m-20 concrete in foundation footing of size 600 mm dia 750 mm depth from top inside the pre-cast RCC collar ( NP-2) of 600 mm Internal dia. & length of 750 mm placed over a base of PCC (1:4:8) of size 680mm dia, 100 mm depth including excavating foundation pit for each pole, kind of soil of size 680mm dia, 850mm depth ( at expansion joint of 15.4 m interval where combined poles are to be places with 900mm internal dia of NP-2 collar of 750mm height) including watering & curing for required days along with supplying, fitting & fixing of pre-cast , pre-tensioned, SFRC slab having dimention of 2100mm (long) x 300mm (Wide)x 50 ( thick) 7.5 Nos. per span, made with M-30 grade concrete with 4mm dia. GI HTPC wire 4 Nos. covering the top of the compound wall poles with a pre-cast SFRC cover of size ( 300x300x150) mm in order the prevent the slab panels from removing . all complete as a set to be measured in term of running meter including such pre-cast , SFRC top cover, slab, pole, including painting two coats of approved weather coat paint over a coat of wall primer including curing cost and conveyance of all materials, royalties, taxes all labour, labour cess, T&P required for the work etc. complete including dewatering if required as per the direction of the Engineer-in-Charge(Excluding cost of GST) Compound wall |
| 229 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre. Compound wall |
| 230 | EARTH FILLING-Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. Land development and surface filling |
| 231 | Supply & Installation of AIFF/FIFA Compliant Portable & Movable Football Goal Post , Size 7.32 M X 2.44 M Inner to Inner, With 8 Inch Non Marking solid Galvanised Wheels for smooth movement, Main pipe made of 100mm Round Powder Coated High Grade Aluminium Alloy Pipe of 3mm thickness, Back Support made of 60mm Round Powder Coated High Grade Aluminium Alloy Pipe of 2.5 mm thickness, No sharp edges, All corners fully welded and ground smooth, 220 Pcs Polyproplene unbreakable net clips no sharp edges, including transportation, Installation, testing & commissioning as per Engineer-In-Charge Must be of reputed make like Stag Global, Nelco, SodexSport. |
| 232 | Supply & Installation of FIVB Compliant Portable & Movable telescopic Volleyball Post, Made of heavy duty 100mm round Aluminium Alloy Pipe with crank system for height adjustment 2.43 m for mens & 2.24m for womens, With 120kgs Weight Stacks for stability. Steel pulley on top, including transportation, Installation, testing & commissioning as per Engineer-In-Charge. Must be of reputed make like Stag Global, Nelco, Senoh |
| 233 | Supply & Installation of Kho Kho Pole,Two rigid poles of 1.20 m height from ground level, Heavy Duty 4 inch Dia Smooth & Round Steel Uprights, No sharp edges to prevent injury. Must be of reputed brands like Nelco, StagGlobal, Gravolite |
| 234 | Supply & Installation of TTFI/ITTF Certified Table Tennis Table, Size 274cm X 152.5cm X 76cm, 25mm Top to ensure consistent bounce & optimal Spin Performance. 25 X 50 mm Heavy-duty alloy steel frame for superior durability and strength. Smooth, Axalta Polyurethane Anti-Glare top Finish for clear visibility and accurate play. Top Colour Black. Must have 100 mm eight wheels for easy mobility, with four being lockable for added stability. Premium Professional T T Tables with Foldable Design. N. W. / G. W. - 116 Kgs / 123 Kgs, including transportation, Installation, testing & commissioning as per Engineer-In Charge. Make - Stag Global, Donic or Stiga |
| 235 | Supply & Installation of BWF Certified Movable Badminton Post With 80 Kg Cast Iron Base for stability, 75 mm Nylon Wheels & Anti Stick PU Rubber Sheet Inside Base and Weights. 95x46mm Square Steel Pipe Connecting the Base & Uprights. 39mm Round Uprights of 4mm thickness. Uprights Height Must be 1.55 Mtr. Stainless Steel Pully Strong System. Powder Coated Rustproof. Must be approved by BWF. Make - Yonex AC 357-1, Stag Global SGBAPO10, Li Ning OP80 |
| 236 | Providing, supplying Nyon BADMINTON NET With 4 side tape (Tournament Quality) of approved quality, size as per specificationand direction of Engineer-In-ChargeMust be Approved by - BWFMust be of reputed make like Yonex, Li Ning, Cougar |
| 237 | Providing, supplying Badminton racket of approved quality, size as per specification and direction of Engineer-In-Charge.Must be of reputed make like Yonex, Vextor-X or Li Ning |
| 238 | Providing, supplying Nylon Shuttle Cock Tournament approved quality, size as per specificationand direction of Engineer-In-Charge.Must be of reputed make like Yonex, Li Ning, Vector X |
| 239 | Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification and direction of Engineer-in-charge. Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm. |
| 240 | Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm. |
| 241 | Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.( Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). |
| 242 | Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge. |
| 243 | Providing and fixing post delineators made of ABS round body fitted with 2 nos 100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder coated anti-rust and anti theft steel to be installed as per direction of Engineer-in-charge. |
| 244 | Providing and fixing letters made out of acrylic sheet with light arrangement as per the architectural drawing/design complete with all materials cost, coveyance, loading and unloading, royalties and cost of all labour, T&P, sundries, with necessary scafolding & accessories complete in all respects as per the direction of architect / engineer in charge.600mm height |
| 245 | 300mm height |
| 246 | Plastic Waste bin Rectangular alongwith fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity-60 350x350 mm Top Dia.250x250 mm Bottom Dia.850 mm Height pair Sintex, Nilkamal, Otto, Aristo |
| 247 | Plastic Waste bin without Wheel with Push type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level capacity 60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo |
| 248 | Plastic Waste bin without Wheel with Swing lid type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity-60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo |
| 249 | Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of land manure before and after flooding trench with water (excluding the cost of imported earth, sludge or manure). |
| 250 | Supplying and stacking of good earth at site (Earth measured in stacks will be reduced by 20% for payment) with all lead and lift. |
| 251 | Supplying and stacking sludge at site (sludge measured in stacks will be reduced by 8% for payment) with all lead and lift. |
| 252 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment).Screened through sieve of I.S. designation 20 mm. |
| 253 | Screened through sieve of I.S. designation 16 mm |
| 254 | Screened through sieve of I.S. designation 4.75 mm |
| 255 | Rough Dressing the trenched ground including breaking clods etc.all complete as per the direction of Engineer-in-charge. |
| 256 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
| 257 | Fine dressing of the ground |
| 258 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 259 | Mixing earth and sludge or manure in proportion specified or directed. |
| 260 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge |
| 261 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. |
| 262 | Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 60 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (The manure/sludge shall be paid for separately). |
| 263 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately). Holes 60 cm dia, and 60 cm deep |
| 264 | Holes 45 cm dia, and 45 cm deep |
| 265 | Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. |
| 266 | Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge.Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4 mm |
| 267 | Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer incharge. (The cost of good earth, earthen pots & manure will be paid separately.) Size of Empty Pots 35cm Top dia, 25cm Bottom Dia & 35cm Perpendicular height. |
| 268 | Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. |
| 269 | Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. |
| 270 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water). Trees Plant |
| 271 | Shrubs Plant |
| 272 | Hedge Plant |
| 273 | Providing and displaying of Aglaonema dove variety Plant, having ht. 30 cm to 45 cm with 8 to 10 leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. |
| 274 | Providing and displaying of Aglaonema Snow-White hybrid plant (three in one), having ht. 30 cm & above with 6 to 8 leaves, bright colour, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot . (Specimen Plant) & as per direction of the officer-in-charge. |
| 275 | Providing and displaying of Areca Palm plant, having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 20 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. |
| 276 | Providing and displaying of Croton Challanger variety plant, having ht. 30cm and above, well developed with full of fresh and healthy leaves in 20 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. |
| 277 | Providing and displaying of Croton Baby Golden plant (three in one), having ht. 30cm, multi branches, well developed with fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot. as per direction of the officer-incharge. |
| 278 | Providing and displaying of Dracaena Song of India plant (three in one), having ht. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. |
| 279 | Providing and displaying of Money Plant Broad Leaves mounted on moss stick 90 cm ht., 3 to 4 plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot . & as per direction of the officer-in-charge. |
| 280 | Providing and displaying of Phoenix palm plant, having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. |
| 281 | Providing and Displaying plants Cladium Hybrid variety 3 to 4 plants in a pot well developed with fresh & healthy foliage 30 to 45 cm ht. in different colour 25 cm Earthen Pot/Plastic Pot and as per direction of the officer incharge. |
| 282 | Providing and Displaying plants Cosmos well developed fresh & healthy 20 to 25 cm ht. attractive colours multi branching at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 283 | Providing and Displaying plants Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 284 | Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 285 | Providing and Displaying Acalypha green plant well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot bushy plant as per direction of the officer-in-charge. |
| 286 | Providing and Displaying Bamboo Buddha vally variety with umbrella shape plant having 120 to 135 ht. with fresh & healthy foliage well developed in 40 cm Cement pot multy branch, bushy plant as per direction of the officer-in-charge. |
| 287 | Providing and fixing overhead type sprinkler system with self closing valve type 25mm X 20mm with self closing spring made up of alluminium alloy and brass fittings including cost of all materials, labour, T & P etc complete as per direction of Engineer-in-charge. |
| 288 | Supplying all materials, labour, T&P and fixing 15mm dia CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 289 | Supplying all materials, labours, T&P and fitting and fixing of the 20mm dia CPVC pipe confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge. (Concealed) |
| 290 | RECEPTION CHAIR MODEL-BRAVO MID BACK CHAIR Providing and Supplying of furniture 1.SEAT/BACK ASSEMBLY: The seat and back should be made up of 1.2 ±0.1cm. thick hot-pressed plywood and upholstered with .fabric upholstery covers and moulded Polyurethane foam. The back foam should be designed with contoured lumbar support for extra comfort. The seat has extra thick foam on front edge to give comfort to popliteal area.BACK SIZE 47.5 cm. (W) x 69.5 cm (H)SEAT SIZE 47.0 cm. (W) x 48.0 cm. (D) 2.. HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density = 45±2 kg/m3 and hardness load 16 ± 2 kgf for 25% compression. 4. CENTER TILT SYNCHRO mechanism: The mechanism should be designed with the following features: • 360° revolving type. • Upright-position locking • Tilt tension adjustment • Seat/back tilting ratio of 1:3. 5.PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 12.0 ±0.3cm.6.TELESCOPIC BELLOW ASSEMBLYThe bellow should be 3 piece telescopic type and injection moulded in black Polypropylene at the site as per approved design and direction of Engineer-in-Charge. (Make-Godrej, Steel Case, Herman Miller.) Indoor hall. |
| 291 | RECEPTION TABLE MODEL-REFLECTION 5FT WIDTH LEANER DESK Providing and Supplying of furniture Work Surface: Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Access Flap provided on work surface for wire management. Wire Management: Power box made with 0.8 mm thick CRCA (IS: 513), with switch plate (8+3 Module cutout provision for Anchor Roma), Edge banded with matching 2 mm thick PVC lipping. TOP shelf: Made of 18mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Essential Accessories:Wire Riser made of 0.8mm CRCA (IS-513) is provided for magnetic sticky notes. Bag Hanger Hook made of 1.2mm CRCA (IS-513) is provided for bag hanging at the site as per approved design and direction of Engineer-in-Charge. (Make-Godrej, Steel Case, Herman Miller.) Indoor hall. |
| 292 | Table - TABLE CIGNUS 2100 + ERU+ PEDESTAL + BACK UNIT 1800 (TABLE MAIN DESK SIZE - 2100W X1050D x 750H, ERU-1200Wx450Dx750H),BACK UNIT SIZE - 1800Wx500Dx1800H) IN MM Providing and Supplying of furniture Primary Work Surface:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Secondary Work Surface:Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top.Softclosing access flap with in-build power box are provided on work surface for wire management.Modesty Panel:Made of 25mm thick MDF one side laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to topUnder- structure:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Integrated Pedestal:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping at the site as per approved design and direction of Engineer-in-Charge. Indoor hall. |
| 293 | Chair - BEAT HIGH BACK-SEAT/ BACK ASSEMBLY: The seat & back is made up of 1.2 ± 0.1cm thk. hot pressed plywood measured as per QA method described in OCP-QLTA-PL14-18 ; upholstered with synthetic leather over moulded High Resilience . • Fixed Armrest Top is PU moulded over metal insert.FRONT PIVOT SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features.• 360° revolving type. • Single point control. • Front-pivot for tilt with feet resting on ground ensuring more comfort. • Tilt tension adjustment. • 4-position locking with anti-shock feature. Back height adjustability is applicable for for High back and Mid back chair.PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 10.0 ± 0.3 cm. Indoor hall. |
| 294 | Facility centre |
| 295 | VISITOR CHAIR MODEL-BEAT VISITORProviding and Supplying of furniture SEAT/BACK ASSEMBLY: The seat & back is made up of 1.2 ± 0.1cm thk. hot pressed plywood measured as per QA method described in OCP-QLTA-PL14-18 upholstered with knitted fabric , over moulded High Resilience Polyurethane foam SEAT SIZE : 49.0 cm. (W) x 51.4 cm. (D)TUBULAR VISITOR FRAME (Visitor Chair): The tubular frame is powder coated ( DFT 40-60 microns ) cantilever structure & made of Dia.Ø 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. M.S. E.R.W. Tube with a connecting M.S. Spine welded to it. Back spine is fitted to the frame assembly.( at the site as per approved design and direction of Engineer-in-Charge. (Make-Godrej, Steel Case, Herman Miller.) Indoor hall. |
| 296 | Almirah - Storwel Plain (1981H x 916W x 486D)Storwel plain shall have an overall size of 916mm(W)x486mm(D)x1980mm(H) with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (,/- 10). Plenty of colour options and shelving options shall be available. Indoor hall. |
| 297 | Facility centre |
| 298 | EASY RACK 6615 (SIZE - 1800Hx900Wx450) IN MMSlotted Angle 4 nos, with 6 nos Self. Indoor hall. |
| 299 | Facility centre |
| 300 | Table Model- Enterprise 1500 W/o CPU hanger (SIZE - 1500W x 750D x 740H) IN MMOverall size of 4 - Door PLU + Lkr (Base) shall be 380mm(W)x450mm(D)x1830mm(H). Stackability shall have add - on units that can be stacked width wise to form bank of lockers having common side panel. Locking shall have 10 Lever cam lock with lock lever plus option of hasp arrangement . Material shall be CRCA 0.6 mm thickness . Construction shall be Rigid Knockdown construction , shelf shall be uniformly distributed load capacity per each shelf level is 35 Kg maximum . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Handle/Label holder shall be Aesthetically appealing Snap fit ABS plastic handle . Ventilation shall be attractive punched pattern for ventilation. Indoor hall. |
| 301 | Facility centre |
| 302 | Teacher Chair Model - Beat Mid Back ChairSEAT/BACK ASSEMBLY: The seat & back is made up of 1.2 ± 0.1cm thk. hot pressed plywood measured as per QA method described in OCP-QLTA-PL14-18 ; upholstered with synthetic leather over moulded High Resilience Polyurethane foam.* MID BACK SIZE: 51.6 cm. (W) x 65.7 cm. (H) ,* SEAT SIZE: 49.0 cm. (W) x 51.4 cm. (D) • Up-Down adjustment– 8 steps (8.0±0.5cm range) • Height adjustable armrest structure which is chrome plated & fitted with an armrest top. • Fixed Armrest Top is PU moulded over metal insert.FRONT PIVOT SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features.• 360° revolving type. • Single point control. • Front-pivot for tilt with feet resting on ground ensuring more comfort. • Tilt tension adjustment. • 4-position locking with anti-shock feature. • Seat/back tilting ratio of 1:2.BACK HEIGHT ADJUSTABILITY: Back can be adjusted in 5 positions by manually. Stroke of height adjustable spine is 7 cm. Back height adjustability is applicable for for High back and Mid back chair.PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 10.0 ± 0.3 cm. Indoor hall. |
| 303 | 4 - Door PLU LockerOverall size of 4 - Door PLU + Lkr (Base) shall be 380mm(W)x450mm(D)x1830mm(H). Stackability shall have add - on units that can be stacked width wise to form bank of lockers having common side panel. Locking shall have 10 Lever cam lock with lock lever plus option of hasp arrangement . Material shall be CRCA 0.6 mm thickness . Construction shall be Rigid Knockdown construction , shelf shall be uniformly distributed load capacity per each shelf level is 35 Kg maximum . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Handle/Label holder shall be Aesthetically appealing Snap fit ABS plastic handle . Ventilation shall be attractive punched pattern for ventilation. Indoor hall. |
| 304 | Facility centre |
| 305 | LOOP BENCH INGRID V2Overall size of 4 - Door PLU + Lkr (Base) shall be 380mm(W)x450mm(D)x1830mm(H). Stackability shall have add - on units that can be stacked width wise to form bank of lockers having common side panel. Locking shall have 10 Lever cam lock with lock lever plus option of hasp arrangement . Material shall be CRCA 0.6 mm thickness . Construction shall be Rigid Knockdown construction , shelf shall be uniformly distributed load capacity per each shelf level is 35 Kg maximum . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Handle/Label holder shall be Aesthetically appealing Snap fit ABS plastic handle . Ventilation shall be attractive punched pattern for ventilation. Indoor hall. |
| 306 | Facility centre |
| 307 | E.I. WORKCOMMON FACILITY CENTERRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box - Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)NB:All the electrical,Fire fighting,HVAC,ELV drawings,LUX Level design of the arena lighting, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A |
| 308 | GROUP-B |
| 309 | GROUP-C |
| 310 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 311 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 312 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 313 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 314 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 315 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 316 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 317 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 318 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4) |
| 319 | Supply, delivery, installation & testing of Modular G.I. box 18 SWG Sheet ISI marked with Modular base & cover for 2 moudle tv socket outlet.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 320 | Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm2 Four Pair Copper Conductor Telephone Wire run inside prelaid PVC Conduit complete including termination, testing etc complete as required and as per Direction of Engineer-In-Charge. |
| 321 | Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as per Direction of Engineer-In-Charge. |
| 322 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 323 | Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . In case, the distance between ODU and IDU exceeds 3 mtr, then only the item of copper pipe shall be executed without any joint and equivalent mtr shall be deducted from the copper pipe item.1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-ASGG18CGWA-B/ Daikin-FTKU50XV16) |
| 324 | Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 325 | Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job. |
| 326 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)20 MM |
| 327 | 25 MM |
| 328 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 329 | Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow1500 CFM @ 15mm MMWG static pressure |
| 330 | Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness) |
| 331 | 24 gauge (0.63 mm thickness) |
| 332 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 333 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) . |
| 334 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 335 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 336 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 337 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 338 | Supply, Installation, Testing & Commissioning of of IP65 (10-12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 339 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 340 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 341 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year. |
| 342 | Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year. |
| 343 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 344 | Supply ,installation ,testing & commissioning of 5KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer of 1ph in put to 1 ph output,230V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 26AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for services building |
| 345 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (with charcoal and salt) as required and as per direction of Engineer-in-charge. |
| 346 | Providing and fixing 6 swg GI wire on surface or in recess for loop earthing as required and as per direction of Engineer-in-charge.. |
| 347 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 348 | S/I/T&Commissioning of LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA..In commer--01 number of 125 Amps MCCB 25 KA , 01 number of 125 Amps 4P onload type Changeover with both source ON/OFF indication (Make-Siemens/Schneider/ABB/LEGRAND)Busbar- 04 numbers of 125Amps 50kA Aluinuium busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (ii) 03 nos 63A 4P MCB 10kA,C series , 03 nos 63A DP MCB 10kA,C series, 02 nos 32A DP MCB 10kA,C series LIGHT BDB AC IDU BDB/LIGHT BDB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication for both the source with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)..(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 63/5A 3 nos class 1 type(Make-Siemens/Schneider/ABB/Legrand) |
| 349 | Supplying and fixing 32amps rating,double pole mcb type changeover 240 volts, C series,10KA breaking capacity, of Make-LEGRAND/ Siemens/ Schneider/ABB the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. for UPS Outgoing ) |
| 350 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm |
| 351 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x50 sq mm |
| 352 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 353 | Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m) |
| 354 | Danger Board. |
| 355 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 356 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog .4.5 kg capacity |
| 357 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog.6 kg capacity |
| 358 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit. |
| 359 | SITC of Cat6 I/O with single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 360 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 361 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length) |
| 362 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length) |
| 363 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 364 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 365 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit |
| 366 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 367 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 380W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP |
| 368 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 369 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 370 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch |
| 371 | Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).Make-Honeywell value series /Pelco/Axis/Bosch |
| 372 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 373 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 374 | INDOOR HALLRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box - Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)NB:All the electrical,Fire fighting,HVAC,ELV drawings,LUX Level design of the arena lighting, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. Group-A |
| 375 | Group B |
| 376 | Group C |
| 377 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 378 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 379 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 380 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 381 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 382 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 383 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 384 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 385 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4) |
| 386 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 387 | Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABBSB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 388 | Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 1 year. |
| 389 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 390 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 391 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 392 | Supply, Installation, Testing & Commissioning of of IP65 (10-12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 393 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 394 | Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 395 | Supplying, installation, of 100W WALL Mounted industrial metallic fan of 450 mm sweep 1440 rpm, 150 cum/min. aluminium blade , 100% copper winding, 3 speed control (Make- Havells/Crompton/Usha/Bajaj /Orient) of wall fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 396 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Bajaj/Orient ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 397 | Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow1500 CFM @ 15mm MMWG static pressure |
| 398 | Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness) |
| 399 | 24 gauge (0.63 mm thickness) |
| 400 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 401 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) . |
| 402 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 403 | Supply, Installation, Testing and Commissioning of Linear LED SPorts light with Max system power of 80W , CCT 5700K +/-355K as per ANSI , CRI>80, SDCM<3 , with Minimum delivered lumen of >11,500 lumens . The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66 and Impact Resistance of IK08. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare & best in class uniformity( Glass cover not allowed) . Luminaire housing should carry OEM's logo embossed / engraved (no stickering is allowed). the Length of Luminaire should be between 900mm-1000mm or as per approved design . The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-305V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : DM 4kV, CM 6kV and upgraded with integrated External IP67 protected SPD of 20KV/10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. All supporting documents like Technical data sheet of Luminaire & Driver, LM79 test reports including test reports photometry , TTC, IP, IK, Vibration and salt spray test from third party NABL accredited Laboratory. LM80 from LED OEM .BIS of the Luminaire should carry the Own factory address of OEM, vendor facilities are not acceptable.(5 years warranty)All arena light shall be supplied from UPS DB. Make- Philips/ Lighting Technologies/ Schréder/Equivalent |
| 404 | SITC of high-quality integrated LED Flood Light with a minimum system lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with SDCM of < 5 and CRI >=80. The housing should be of pressure die-cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF > 0.95, THD<10%, Lifetime of 50K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be >=500 LUX ,min to average shall be >=0.7, min to max shall be >=0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement.(4 Nos. for each pole) Only sport series flood light will be accepted.Make- Philips/ Lighting Technologies/ Schréder/Equivalent |
| 405 | Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 6nos. or more of flood light as per final lux level design) manufactured from HT steel having base dia if 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Valmont /Vakrangee |
| 406 | Construction of pedestal type foundation with M20 grade concrete for pole 2000mm depth x 550mm length x 550mm breadth including all material and labour as per the direction of Engineer-in-charge. The structural calculation and civil foundation shall be duly approved by the competant authority from civil wing before execution of the work. |
| 407 | Supply ,installation ,testing & commissioning of 10 KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 1 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 42AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for INDOOR HALL building |
| 408 | Main panel :S/I/T&Commissioning of LT OUTdoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 50X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 65 kA 3P+N type 1+2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given.In commer- 01 no 400 A 4P MCCB 36kA LSIG Microprocessor release ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) Busbar- 04 numbers of 500 Amps aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 04 nos 125 A 4P TMR MCCB 25kA with Ics=100%Icu01 nos 250 A 4P MCCB 25kA TMR MCCB 25kA with Ics=100%Icu Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 , Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-400Amps Ammeter with CTS.(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)(iii) 01 set of 0-500 voltmeter .(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)Make of SPD-Legrand/ABB/schneider/Siemens/obo/dehn |
| 409 | CONTROL PANEL:S/I/T&Commissioning of LT OUTdoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given.In commer1- 01 no 125A 4P MCCB 25 kA tmr ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) with125A 4P Manual changeover In commer2- 01 no 125A 4P MCCB 25 kA tmr ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) with125A 4P Manual changeover Busbar- 04 numbers of 300 Amps Aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 12 nos 100-63 A 4P MCCB 16kA TMR with Ics=100%Icu ,02 nos 63/40 A 4P MCB 10KA C series, 02 nos 63/40 A DP MCB 10KA C seriesInstrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 02 set of 0-300Amps Ammeter with CTS.(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)(iii) 02 set of 0-500 voltmeter .(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)Make of SPD-Legrand/ABB/schneider/Siemens/obo/dehn(iv) 02 sets of 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA |
| 410 | INDOOR LIGHT PANEL FOR ARENA :S/I/T&Commissioning of LT OUTdoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed..All the incomers shall have 20kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given. Incomer: 32 A DP MCB (10 KA) , C series Bus bar: 2 numbers of 63Amps copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. VMR with microprocessor based overvoltage,over current protector OUTGOING : 26 NOS 6 A DP MCB 10KA , C series Instruments: Instrument- (i) 01 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(Make-Legrand/ABB/schneider/Siemens) below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge..MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FormulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9/ABB SB200 |
| 411 | OUTDOOR LIGHT PANEL:S/I/T&Commissioning of LT outdoor floor mounted doubledoor CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given.Incomer:63 A 4P MCCB (16 KA) with adjustable thermal setting Ics = 100% of Icu Busbar- 04 numbers of 300 Amps Aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. OUTGOING : 5 Nos 40A 4P MCB. (10 KA), C series , Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-200Amps Ammeter with CTS.(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)(iii) 01 set of 0-500 voltmeter .(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FormulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9/ABB SB200 |
| 412 | outdoor light sub panel :Design, Supply, Installation, Testing and Commissioning of LT outdoor floor mounted doubledoor type with CRCA 2mm thick Mast Lighting Distribution Boards ( MLDB) for operation of the lights on Stadium masts.Mandatory provision of Cable alley is to be given.incomer-40A, FP MCB, C series,10kA , 100 Amp.aluminum Bus Bar - 4 Nos. by color coded PVC sleeve & supported by suitable size DMC insulator and outgoing 6A DP MCB, C series,10kA-10 nos with one no.40kA type 2 3P+N SPD with 63A 4P MCB, C series, 10kA in the incomer and other accessories as per direction of Eng-in-charge.Make of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 413 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)20 MM |
| 414 | 25 MM |
| 415 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.3.5 core x 240 sq mm Aluminium armoured Cable.(FOR control /MAIN PANEL) |
| 416 | 3.5 core x 70 sq mm Aluminium armoured Cable.(FOR dg) |
| 417 | 3.5 core x 50 sq mm Aluminium armoured Cable.(FOR OUTDOOR LIGHT PANEL) |
| 418 | 3.5 core x 25 sq mm Aluminium armoured Cable.(for INDOOR & SUB OUTDOOR light) |
| 419 | Supply and laying of 4 core x 10 sq mm Aluminium armoured Cable.(for VENTALLATION ) |
| 420 | Supply and laying of3 core 2.5 sqmm Flexiable copper cable (for Hall light and flood light) |
| 421 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.3.5 core x 240 sq mm brass double compression gland and aluminium lugs |
| 422 | 3.5 core x 70 sq mm brass double compression gland and aluminium lugs |
| 423 | 3.5 core x 50 sq mm brass double compression gland and aluminium lugs |
| 424 | 3.5 core x 25 sq mm brass double compression gland and aluminium lugs |
| 425 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 426 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 427 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 428 | Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.18 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 429 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 430 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including the cost of material ,labor T & P as required as EIC. |
| 431 | Supplying,fixing of hot dip galvanized powder coated GI perforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 432 | Supplying,fixing of perforated cable trays with horizontal & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 433 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 434 | Supply installation, testing and commissioning of single piece long casing (motor should completely be accommodated inside the fan casing, multi piece casing are not acceptable) Tube Axial Fan in MS with powder coated / GSS, Al impeller with adjustable blade angles (Manually Adjustable at Site), bird screen ,gravity louvers, fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (IE3) F Class insulation for pressurization suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. All offered fans pitch angle shall be AMCA Certified & Listed on AMCA website (Interpolation of pitch angle shall not be acceptable) and Fan Efficiency Grade ( Min FEG 71, lesser is not acceptable).Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm & Dia 1600 – 5 mm. All fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade.Fans for emergency application Tube axial are to be used. Sound level for emergency operation it should not exceed 818 Db(A)@ 3 meter (Room condition).Incase of not achieving sound , attenutor has to be added. Outlet velocity of the fans should not exceed 16 m/s for emergency application. (For Exhaust) Make-Krugger/Nikotra/Greenheck/ELTA/Airflow4500 cfm, st pressure 30mm for HALL AREA |
| 435 | SITC of two-stage Indirect-Direct Evaporative Cooling (IDEC) unit with Air Flow Capacity: 12,700 CMH (7,500 CFM), External Static Pressure (ESP): 300 Pa, Cooling Type: Indirect + Direct Evaporative, Supply Air Fan Motor: 5.5 kW, Working / Secondary Air Fan Motor: 1.1 kW, Water Pump: 0.25 kW x 2 Nos, Power Supply: 415 V / 3 Phase / 50 Hz designed to supply 100% fresh, cooled outdoor air.The fan should have Double skin casing with thermal insulation,Outer skin: PPGI,Inner skin & wet section: SS 304, High efficiency polymer air-to-air heat exchanger, High efficiency antibacterial cellulose cooling pads,Stainless steel water tank with corrosion resistant coatingThe first stage uses an air-to-air indirect evaporative heat exchanger, followed by a second stage of direct evaporative cooling using high-efficiency cellulose pads. Make-DRI/OXYCOM/FLAKTGROUP |
| 436 | Supply, Manufacturing, fixing,testing and commisioning of Factory Made Flat Oval Spiral Duct with 10 mm open cell antimicrobial 180kg/cum class 'O' ACOUSTIC AND THERMAL insulation .The cost of Insulation shall be included in the ducting Cost with adhasive and all necessary accessores. The Thickness of the Duct shall be of 22 G only shall be as per Ducting SMACNA standards of Flat Ovel Duct . The Cost of Hanging arrangemnet shall be included as per OEM standards and also the GI Hook or GI angle, support clamp shall be used . all nut Bolt shall be of Hot Dipped Galvanized GI nut with washer shall be Used . The Cost of Threaded Rod and Necessary fastner shall be included in the Cost of Ducting Its Self .The Duct Shall be Joint with the POP up rivit or Self Fasting GI screw with Sealent . the Length of Duct Shall be either 4 , 10 or 12 Feet . Branch Peices can be as per the Site Design Requirment . The Duct Collar Can be of Single layer with Insulation to acomodate the Air Distribution Product MakeTATA/SAIL/JINDAL22 GAUGE (0.80 mm thickness) |
| 437 | Supply, Manufacturing, fixing,testing and commisioning of GI ducting (180 gsm)complete with supports,dampers etc.as per specifications. MakeTATA/SAIL/JINDAL22 GAUGE (0.80 mm thickness) |
| 438 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 439 | Supplying, Fixing, testing and commissioning of fire dampers of minimum 90 minutes fire rated in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required.. |
| 440 | Smoke & Fire Dampers. (Make: Air Flow/ Systemair/ Dynacraft) |
| 441 | Actuators and control panel. (Make:- Belimo/ Siemens/ Danfoss) |
| 442 | Design, manufacture, supply, installation, testing and commissioning of the following OUTDOOR TYPE cubicle type, wall mounted control panels including anchoring into the wall, wiring and earthing terminating into MPCB in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contact for Connections to Building Automation System, single phase preventer (Electronics type) as per the ratings given below. Terminal block for power distribution, Power Contactor.Phase indicating lights and indicating light for ON/OFF/TRIP status phase sequence relay shall also be provided.96 mm x 96 mm digital voltmeter and ammeter with selector switches. Suitable rating starter required as a bypass arrangement in case of VFD failure.Time delay relay for delayed automatic restart of air handling unit motor.(0-180 Sec).Make of switchgear-Legrand/ABB/Siemens/Schneider Make of VFD-HVAC Series of Siemens/Schneider/ABB/DANFOSSWiring for microswitch for starting / stopping the fan when fire damper closes / Power supply for fire damper control panel.For on/off/remote and local operation, 3 pole single throw switch shall be provided in each ventilation fan panel to facilitate override of the automatic operation.All starters shall be provided with suitable potential free contract for connections to the Building Automation System.The number of AHU control panels shall be as follows.63 TPN MPCB with 7.5 HP Three phase Motor with Star Delta Starter. Each of these compartment shall contain indicating lamp with ON/ OFF/ TRIP status of the motors. (Cost of VFD is part of Panel) |
| 443 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 444 | Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB |
| 445 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 446 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 447 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 448 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 449 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 450 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OOBO/Dehn/ABB |
| 451 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB |
| 452 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 453 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 454 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 455 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 456 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 457 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 458 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 459 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB |
| 460 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 461 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB |
| 462 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 463 | Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m) |
| 464 | Danger Board. |
| 465 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 466 | Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room.. |
| 467 | SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages |
| 468 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 469 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch |
| 470 | Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).Make-Honeywell value series /Pelco/Axis/Bosch |
| 471 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 472 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 473 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit. |
| 474 | SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 475 | SITC of Cat 6, 24-port loaded, 1U Modular patch Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 476 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length) |
| 477 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(3 mtr length) |
| 478 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 479 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 480 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit |
| 481 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 482 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP |
| 483 | Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.Make-Wilo/KSB/Kirloskar/Grundfoss |
| 484 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make-Legrand/schneider/Siemens/ABB |
| 485 | Supply & Laying ofAl armoured XLPE power cable of 1.1 KV grade of following size on Cable3C X 16 sqmm xlpe Armoued cable |
| 486 | Cable laying Laying & fixing of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on Cable Tray as required.Upto 35 Sqmm |
| 487 | End Termination 3C X 16 sqmm |
| 488 | Supplying, installation testing and commissioning of the following-: ‘C’ class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pyp kote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation.Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete. Make-TATA/JINDAL/SAIL100mm NB |
| 489 | 80mm NB |
| 490 | 25mm NB |
| 491 | Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C.Make-Zoloto/AUDCO/Leader100mm NB |
| 492 | Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/AUDCO/Leader100mm NB |
| 493 | Supply,Installation,Testing & Commissioning of orifice plate made of 6mm thick stainless steel with orifice of required size in between flane and landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 Kg/ sq cm complete as required. |
| 494 | Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: H.GURU/G.GURU |
| 495 | Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: DANFOSS/INDFOSS make |
| 496 | Supply,Installation,Testing & Commissioning of 100 MM stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/AUDCO/Leader |
| 497 | Supply,Installation,Testing & Commissioning of Air vessel made of 250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint as required. |
| 498 | Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 499 | Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 500 | Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 501 | Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 502 | Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 503 | Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge. |
| 504 | Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 100mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Minimax/Newage/Fireshield/Safex |
| 505 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog .4.5 kg capacity |
| 506 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog.6 kg capacity |
| 507 | Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets. |
| 508 | Supplying, installing, testing and commissioning of photo electric adressable multi sense smoke detector with inbuilt isolator module/isolator base ,base, junction box and other accessories.Make-Morley IAS/Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 509 | SITC of Response Indicator..Make-Morley IAS/Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 510 | Supplying, installation, testing and commissioning of Intelligent Reflective Beam Detector with 4 pieces Reflectors, Capable used as Conventional detector, Fire and Fault signal relays available, 24VDC required, Detection Range 8-100 Meters (Certified by LPCB): GREEN / AMBER / RED Make-Morley IAS/Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 511 | Supply, installing, testing and commissioning of of 2 Loop Network Panel Micro processor based 2 wire fault tolerant loop,with inbuilt network port (each loop accessing 99 or more detectors and 99 or more modules ) fire alarm/detection control panel. The Panel shall have 10000 or more event log history . Panel shall be capable of having 1600 or more configurable zones .The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFFrespective control module when ever any alarm is triggered. The panel shall have 7 Inch Touch Screen unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have provision for 40 or more Zones with Individual LED Indicators expdable upto 200 Zones or higher. The panel shall have a built in power supply and battery charger along with maintenance free 7 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54 The panel shall support detection logics like coincidence & verification detections for the false alarm management. The Panel shall adjust the sensitivity between day and night to maintain the better detection/reponse time. The Panel shall be capabale of programming through PC ; Touch Screen of USB .This panel having facility of MODBUS protocol over TCP/IP for BMS integration.The panel should have provision for inbuilt RJ45 connection terminal for connecting to the LAN with inbuilt BACNET Protocol. Make- Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 512 | Supplying, installation, testing & commissioning of Addressable Single Output Module,Single Output Module, provides dry contact (Loop powered) or active output (24VDC required, cable monitored) (Certified by LPCB)) indicates system status: GREEN / AMBER / RED.Make-Morley IAS/Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 513 | Supplying, installing, testing and commissioning of Addressable Manual Call Point with back box.Make-Morley IAS/Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 514 | Supplying, installing, testing and commissioning of Analogue Addressable Loop powered Sounder with strobe light.MakeMorley IAS/Siemens/Bosch/Edward/NOTIFIER/GST/Schneider Please Enable Macros to View BoQ information |
| 515 | Supplying, installing, testing and commissioning of Analogue Addressable Loop powered Sounder with strobe light.MakeMorley IAS/Siemens/Bosch/Edward/NOTIFIER/GST/Schneider Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail