Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | DSR 18.7.7 Supply, installation, testing and commissioning of ISI marked MS pipes to IS:1239 C class including all fittings like anchor fasteners, couplings, bends, elbows, tees including supports etc., welded or screwed joints as required, complete Make: Jindal / Apollo/Surya. 100 mm dia |
| 2 | DSR 18.7.6 Supply, installation, testing and commissioning of ISI marked MS pipes to IS:1239 C class including all fittings like anchor fasteners, couplings, bends, elbows, tees including supports etc., welded or screwed joints as required, complete Make: Jindal / Apollo/Surya. 80 mm dia |
| 3 | DSR 18.17 Supply, installation, testing and commissioning of First Aid Fire Hose reel wall mounting swinging type drum with 20 mm dia. x 30 mtr long ISI mark hose bracket of MS construction, spray painted in post office red complete with the following as required Make :- Atasee/ MEC |
| 4 | DSR 18.9.2 Supply, installation, testing and commissioning of landing hydrants Valve to type ‘A’ of I.S.:5290_1977 with 63 mm dia. Stainless steel instantaneous type single headed outlet, with blends caps and chain complete with instantaneous spring lock type SS female coupling of 63 mm dia. for connecting hose type. ISI mark Make :- Atasee/ MEC |
| 5 | DSR 18.16.2 Supply and installation of 63 mm dia. rubber fabric lined hose with stainless steel male female coupling 15 mtr. Long. ISI mark IS 636 type A Make :- Atasee/ MEC |
| 6 | DSR 18.18.2 Supply and installation of stainless steel branch pipe with SS nozzle with 20 mm nominal bore outlet with standard instaneous type 63 mm dia. coupling. ISI mark Make :- Atasee/ MEC |
| 7 | DSR 18.19.1 Supply and installation of 100 mm dia. Two Way Fire Brigade Connections Inlet which is connected to Hydrant main pipe line outside the building including all fitting like flange, nut bolt, gasket etc Make:- Atasee/MEC |
| 8 | DSR 18.11.5 Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required. 100 mm dia |
| 9 | `Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:80 mm dia (DSR 18.11.4) |
| 10 | Providing , installation , testing and commissioning of non return valve of following sizes confirming to IS: 5312 complete with rubber] gasket , GL bolts , nuts, washers etc. as required: ( E and M DSR 2022 , (DSR 18.14.5) 100 mm i/d |
| 11 | DSR 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 core 2.5 sq.mm |
| 12 | DSR 17.5.1 Supplying and laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring and LSZH outer sheath complete as required |
| 13 | DSR 17.1.2 Supply and installation of Photoelectric type Smoke Detector complete with base LED (light emitting diode) with accessories confirming to BS – 5446 Part – 1977 – BS 5445 (EN – 54) Part – VII 1984 dully approved by UL/FM/FOC/ULC/BSA or any other recognized international body, including all testing etc. Complete in all respect up to the satisfaction of person in charge of work. (Make: Agni / System Sensor) |
| 14 | DSR 17.1.3 Supply and installation of Manual Call Points, complete with hammer and chain in the event of smoke of fire is detected by individual so that he may activate the manual call point so as to trigger to control panel and connected alarm devices dully located in glass covering. Including all material and labour required for installation / testing etc. complete in all respect up to the satisfaction of person in charge of work. (Make: Agni) |
| 15 | DSR 17.1.6 Supply and installation of low intensity electronic Hooter Speaker with line matching transformer at working voltage of 24v DC for Fire Alarm and including all material and labour required for installation/ testing etc. Complete in all respect up to the satisfaction of person in charge of work. (Make: Agni) |
| 16 | DSR 17.1.9.2 Supply and installation of Main Fire Alarm Control Panel complete with zones and visual indication of fault and fire. Confirming to be 2189-1988 I and approval of TAC. Including 24 volts DC battery for supply and charger. The panel would be of 16SWG sheet steel rust proof and final finishing of paints including all material and labour required for installation/testing etc., complete in all respect up to the satisfaction of person in charge of work. (Make: Agni) |
| 17 | DSR 18.4.2 Providing and Fixing of Terrace Motor Pump 5 HP complete with fitting Make:- Crampton, Lubi |
| 18 | Supply and installation of 25 mm dia. Ball valve with fitting |
| 19 | Providing and Fixing of auto/manual electrical control panel |
| 20 | Providing and Fixing of Pressure switch with fitting |
| 21 | Providing and Fixing of Pressure Gauge with fitting |
| 22 | Providing and Fixing of 25 mm dia. spring loaded Air Release Valve |
| 23 | Providing and fixing of PVC Water storage terrace tank with necessary fitting 5000 Ltr./ Each Make Jindal |
| 24 | Core Cutting size 100/150 mm |
| 25 | Supply and installation of Single door Fire Hose Cabinet Box with locking arrangement, 4 mm thick glass with M.S. flats including all accessories, painting with one coat of steel primer and two coats of postal red enamel paint complete |
| 26 | Supply and installation of ABC type fire extinguisher cap. 4 Kg. ISI mark Make Atasee/Life Safety |
| 27 | Supply and installation of CO2 type fire extinguisher cap. 4.5 Kg. ISI mark Make Atasee/Life Safety |
| 28 | SITC of 4MP Fixed Bullet Camera for STQC Compliance, Image Sensor 1/2.9 inch Progressive Scan CMOS or better, Resolution Min. 2560 x 1440 @ 20 fpsor better, Video Compression MJPEG, H.264,H.265, Audio Compression `G.711/G.722.1/G.726/MP2L2/PCM/AAC-LC/MP2L2`, Streaming Min. three compressed stream (Individually Configurable), Simultaneous Live View Up to 6 channels, Lens Type 2.8/4 mm, Region of Interest (ROI) 1 fixed regions, Image Enhancement BLC, HLC, 3D DNR, Signal-to-Noise Ratio = 52dB, Wide Dynamic Range 120dB, IR Range IR Up to 30 mtrs, White Light : 20mtrs, Supplement Light Type IR, White Light, Privacy Mask 4 Privacy Masks, Electronic Shutter 1/3 s to 1/100,000 s with slow shutter support, ONVIF Profile S, G, T supported, Operating Temperature ` -30 °C to plus 60 °C Humidity 95% or less (non-condensing)`,Housing IP67, Power Source 12 VDC, PoE: 802.3at/af, Certification CE/FCC/BISER/STQC. MAKE:- PRAMA / CP PLUS / Honeywell |
| 29 | SITC of 4MP Fixed Dome Camera for STQC Compliance, Image Sensor 1/2.4 inch Progressive Scan CMOS or better, Resolution Min. 2560 x 1440 @ 20 fps or better, Video Compression MJPEG, H.264,H.265, Audio Compression `G.711/G.722.1/G.726/MP2L2/PCM/AAC-LC/MP2L`, Simultaneous Live View Up to 6 channels, Physical Layer 1 RJ45 10M/100M self-adaptive Ethernet port, HTTPS encryption, IP address filter, HTTP/HTTPS, WSSE, TLS 1.1/1.2/1.3, security audit log, watermark, Protocol Minimum TCP/IP, UDP, Multicast, NTP, DDNS, SNMP, QoS, DHCP, IPv4/v6, DNS, HTTP, HTTPS, RSTP, SRTP/RTSPS, Bonjour, NAT, UPnP, ONVIF, SSH, SMTP, ARP, FTP/SFTP, Lens Type 2.8mm, Audio Port 1IN/1OUT, Alarm Port 1IN/1OUT, Region of Interest (ROI) 1 fixed regions, Image Enhancement BLC, HLC, 3D DNR, Signal-to-Noise Ratio = 52dB, Wide Dynamic Range 120dB, MicroSD Card Slot MicroSD/MicroSDC/MicroSDXC Card Support upto 512GB, Illumination Colour: 0.005 Lux (@F1.6, AGC ON), 0 Lux with light, IR Range IR Up to 30 mtrs, Supplement Light Type IR, White Light, Privacy Mask 4 Privacy Masks, Electronic Shutter 1/3 s to 1/100,000 s with slow shutter support, ONVIF Profile S, T, G supported, Operating Temperature ` -30 °C to plus 60 °C Humidity 95% or less (non-condensing)`, Housing IP67, IK10, Power Source 12 VDC, PoE: 802.3at/af, Certification CE/FCC/BIS-ER/STQC. MAKE:- PRAMA / CP PLUS / Honeywell |
| 30 | SITC of PTZ Camera with STQC Compliance, Image sensor 1/2.8 inch or better Progressive Scan CMOS, Resolution 4MP, Frame per Second 25 FPS, Dynamic Range 120 dB, Signal to Noise Ratio 52 dB, IR Range 150m or better, Lens `Higher side of focal length should be greater than 130mm varifocal-lens or better Motorized Varifocal and Focus`, Optical Zoom 32x or better, Digital Zoom 16x or better, Horizontal Angle of View 60° to 3° or better, Vertical Tilt -15° to 90° with auto flip, Pan and Tilt Speed `Pan speed: configurable from 0.1° to 160°/s: preset speed: 240°/s Tilt speed: configurable from 0.1° to 120°/s, preset speed 200°/s`, Pan Movement 360°, Video Compression H.265,H.264, Audio 1 Input / 1 Output, Ethernet RJ45 10M/100M self-adaptive Ethernet port, Supported Protocols TCP/IP, NTP, SSL/TLS, HTTP, UDP, IPv4/IPv6, SNMP, DHCP,HTTPS, Local Storage Builtin memory card slot, support micro SD/micro SDHC/micro SDXC card, up to 512 GB, Alarms 1 Input / 1 Output, Operating Temperature -30 °C to 65 °C (-22 °F to 149 °F), Operating Humidity 90% or less (non-condensing), Environmental Protection IP67, IK10, Regulatory Approvals CE/FCC/RoHS/BIS. Make:- PRAMA / Honeywell / CP PLUS |
| 31 | SITC of NVR 32 Channel Incoming bandwidth Min. 300 Mbps, Outgoing bandwidth Min. 400 Mbps, Recording resolution Upto 12MP, Video o/p interfaces `HDMI and VGA simultaneous video output HDMI port-1: Supporting 8K (7680 × 4320)/30Hz) HDMI Port-2: Supporting 4K (4K (3840 × 2160)/60Hz) VGA 1 and 2 ports: Supporting (1920 × 1080/60Hz)`, Audio o/p IN1 and OUT 2, Two-way audio input 1-ch, Compression technique H.264, H.265 or better, Live view/Playback resolution Upto 12MP resolution, Synchronous playback Up to 16 channel, SATA interfaces 8 sata interfaces with each supporting 14 TB, N plus M hot spare, RAID Type RAID0, RAID1, RAID5, RAID6, RAID10, Network interfaces 2, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface, Serial inetrfaces RS-232, RS485: Keyboard, USB interface 2x USB 2.0 and 2xUSB 3.0, Alarm I/O 16/9, Working temperature -10ºC to plus 55ºC, Working humidity 10 to 90 %, Certification BIS/ CE/FCC. MAKE:- PRAMA / CP PLUS / Honeywell |
| 32 | SITC of 6TB Hard Disk consisting of SATA 10TB Surveillance HDD complete in all respect upto entire satisfaction of Engineer-In- Charge of the work. MAKE:- WD / Seagate / Toshiba |
| 33 | SITC of HDMI 1.4 Version, 10.2 Gbps Transmission Bandwidth and 4K @ 30 H- or 4K @ 60H- 4:2:0 Resolution. 10Mtr. (complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.) |
| 34 | SITC of 55 Inch Led smart Screen Resolution - 3840 x 2160, Crystal processor 4K, Mirroring, Wireless TV On, Brightness 350cd/m2, 24/7, Inbuilt Memory 16 GB, 2GB DDR3 2133Mh- RAM, Android OS Version 9, Built in Google Play store, Screen Mirroring for Android and Windows devices, preinstalled APPs: YouTube, Netflix, etc. HDMI x 3, USB x 2, RJ45 x 1, AV IN x 1, SPDIF Out - Yes Optical, Headphone out, Viewing Angle 178/178 degree, Sound Surround Mode - Yes, Speaker output - 2 x 10W, Rated Power Consumption 150W, Standby Power Consumption 0.5W, Power Supply AC 110V — 240V. complete in all respect upto the entire satisfaction of Engineer - in - charge of the work including making necessary connections etc. MAKE:- Samsung / LG / SONY |
| 35 | SITC of 24-port 10/100/1000 Base-T Gigabit PoE plus Managed Switch, 2 dedicated 100/1000 Base-X Fiber SFP ports Bandwidth: 52 Gbps, IEEE 802.3 Ethernet IEEE 802.3u 100BASE-T IEEE 802.1Q VLAN Tagging IEEE 802.3ab 1000BASE-T IEEE 802.3af PoE IEEE 802.3at PoE plus IEEE 802.3az Energy Efficient Ethernet (EEE) IEEE 802.3ad Trunking (LACP) IEEE 802.3z Gigabit Ethernet 1000BASE-SX/LX IEEE 802.3x Full-Duplex Flow Control IEEE 802.1AB LLDP with ANSI/TIA-1057 (LLDP-MED) IEEE 802.1p Class of Service IEEE 802.1D Spanning Tree (STP) IEEE 802.1s Multiple Spanning Tree (MSTP) IEEE 802.1w Rapid Spanning Tree (RSTP) IEEE 802.1X Radius network access control IEEE 802.1x Guest VLAN RADIUS-based VLAN assignment via .1x RADIUS accounting Network Storm Protection DoS attacks prevention Broadcast, Unicast, Multicast Protection Access Control Lists (ACLs) L2 / L3 / L4 IP-based ACLs (IPv4 and IPv6) MAC-based ACL TCP/UDP-based ACL MAC lockdown MAC lockdown by the number of MACs IEEE 802.1x Radius Port Access Authentication Control MAC # Dynamic learned entries: 600 Control MAC # Static entries :20 IEEE 802.1Q VLAN Tagging Video VLAN Voice VLAN IEEE 802.3ad - LAGs - LACP ( (8 LAGS with max. of 8 members in each LAG)) Broadcast Storm Control IGMP Snooping (v1, v2 and v3) IGMP Snooping queriers 802.1ab LLDP SNMP V1, V2, V3 RMON 1,2,3,9 Port-based rate limiting Port-based QoS DiffServ QoS IEEE 802.1p COS IPv4 DSCP Diff Serv QoS IPv4 ToS Cloud/Remote management Password management Configurable Management VLAN Admin access control via Radius and TACACS plus Web-based graphical user interface (GUI) IPv6 management Dual Software (firmware) image Dual Configuration file SNTP client over UDP port 123 SNMP v1/v2 SNMP v3 with multiple IP addresses RMON 1,2,3,9 Port Mirroring Many to One Port Mirroring Cable Test utility SSL/HTTPS and TLS v1.0 for web-based access TFTP/HTTP File transfers (uploads, downloads) HTTP Download (firmware) Syslog (RFC 3164) Per port: Speed, Link, Activity Per device: Power, Fan and PoE Power Status Operating Temperature: 32° to 122°F (0° to 50°C) Operating Humidity: 95% maximum relative humidity, non-condensing Storage Temperature: – 4° to 158°F (–20° to 70°C) Storage Humidity: 95% maximum relative humidity, non-condensing Operating Altitude : 10,000ft (3,000m) maximum, True Lifetime hardware replacement warranty. MTCTE/TEC-ER. MAKE:- Netgear / Cisco / Alcatel |
| 36 | SITC of 8-port 10/100/1000 Base-T PoE Smart managed switch with 2 Fiber Uplinks, Physical Interface 8 # 10/100/1000 Mbps Base-T auto-sensing PoE plus ports 2 # 1000 Base-x SFP uplink ports 500MHz single core CPU or higher 128MB RAM, 32MB SPI FLASH Performance Packet buffer memory min. 512K Bandwidth: 20 Gbps full duplex Priority queues 8 Address database size: 8k media access control (MAC) 256 Multicast groups 32 Number of IPv4 static routes 64 VLANs 256 Number of DHCP snooping bindings 11.9 Mpps Packet forwarding rate Up to 10K Jumbo frames Acoustic noise level @ 25° C 0 dBA (fanless) 8 PoE plus ports Network Protocol and Standards IEEE 802.1Q static VLAN (64 groups, static) VLAN Tagging Protocol-based VLANs MAC-based VLANs Auto-VoIP VLAN / Auto-Voice VLAN Other Requirements Broadcast, multicast, unknown unicast , storm control Protected ports Port-based QoS prioritization on power Dynamic Power allocation DSCP-based QoS PoE timer PoE scheduling/timers Web-based configuration Remote/ Cloud managebility Password access control Multi-site, multi-network single pane-of-glass view TACACS plus and RADIUS support Firmware upgradeable through cloud 54V 1.25A external power adapter Environmental Specifications Operating temperature: 0° to 40° Storage temperature: –20° to 70°C Operating humidity: 90% maximum relative humidity, non-condensing Mean time between failures (MTBF): 1,200,041 hrs (137 yrs) Acoustic noise: 0 dB Storage humidity: 95% maximum relative humidity, Status LEDs Per RJ45 port: Link/activity, speed, PoE status Per SFP port: Link/speed Per device: Power, PoE Max Warranty and Support Lifetime hardware replacement warranty Lifetime free latest firmware support Replacement with New Product Only No refurbished Products. MTCTE/TEC-ER. MAKE:- Netgear / Cisco / Alcatel |
| 37 | SITC of 22U Equipment Rack, Locakable front glass door, cooling facility, internal wiring, front glass door, heat dessipation fans, movement wheels, power distribution units and equipment shelves as required, fully welded construction for strength. Extra-wide rackrail for cable pass-throughs to facilitate front-to-rear cabling. Make: ComRack / Volrack / D-link |
| 38 | SITC of Lockable outdoor IP 66 Junction box for Outdoor Switch and PDU with all necessary accessories, civil, electrical works and peripheral items. Standard. IP 65 Outdoor Pole Rack 9U x 550 W x 500 D Outdoor rack for switch Mounting. Mounting Options: Pole/Wall-Mount with optional Floor/Base-mounting provision. Construction: Welded GI steel, 1.2mm to 1.5mm thickness, front accessibility. Front Door: Equipped with filter, louver, and unique key lock. Material: Galvani-ed steel with anti-corrosive powder coating. Cooling: Two 90CFM, 230V AC fans on front door and top cover for rainwater and dust resistance. Thermal Management: Self-adhesive thermal foam installed inside. Additional Features: Door Hinges: 2 Nos. Gasket: As per IP55 standard. Hood for Air Inlet: Front side. Integrated Side Panels: Welded with canopy and bottom cover. Rigid Frame: For pole fixing. Internal Components: 19” Angles: 2 Nos. for equipment mounting. Hori-ontal Cable Manager: 1U loop type— 1 No. 6 Socket 5Amp PDU: 1 No. Cantilever Tray: 1U, 250mm Depth - 1 No. Load Capacity: 40 kgs or more (static load). Color: Dual-tone grey powder coating (RAL 7035/7037 Combo). Standards: Conforms to DIN 41494 or equivalent. 100% assured compatibility with equipment conforming to DIN 41494. ISO 45001, ISO 9001, ISO 14001, ISO 14064-1. |
| 39 | SITC of Cat 6 A SHIELDED TWISTED PAIR PATCH CORDS (2 Mtr): Conductors Should be of 4 twisted pairs of 26 AWG stranded copper for better flexibility, Patch cords should conform to ANSI/TIA-568-C.2 for Cat 6A, Should |
| 40 | SITC of Cat6A INFORMATION OUTLET (JACK):Should be conform to Category6A as per ANSI/TIA-568-C.2,Should be support network line speeds up to 10 Gbps, I/O operating Life should be minimum 750 insertion cycles and contact |
| 41 | SITC of FACEPLATE(Dual):Single square plate, 86SMx86SM, Write on labels in transparent plastic window – supplied with plate, Screw hole covers – to be supplied with plate, Plug in Icons – Icon tree – to be supplied with plate, Should be |
| 42 | SITC of CAT6 A 24 PORT Shielded JACK-k PANEL LOADED:-Should be supplied with individually replaceable 24 numbers Category-6A I/O shielded Jacks complying as per the ANSI/TIA-568C.2, Should be 19” rack mountable and of 1U |
| 43 | SITC of UTP cat-6 cable. MAKE :- finolex /molex/D-Link |
| 44 | SITC of PVC 25mm. |
| 45 | SITC of Digital Hybrid EPBAX System configured for 4 Analog Trunk Connectivity , 10 Digital Extensions, 60 Analog Extension, It should be suitable for DTMF as well as the FSK type of telephone instruments. It should have built-in multi-party conferencing without any software licensing. It should be possible to carry out 15 conferences of 3-participants at a time. The system shall have built-in web based software programming tool for system administration. The call ringing sequence would be programmable and have options such as simultaneous, hunting off, round robin and delayed simultaneous.The system shall support flexible numbering for extensions such as it may have extensions with 1 digit, 2 digits and up to 6 digits numbers as well as in combination of all.The system should have built-in outgoing Call Log buffer of 6000 calls, incoming call log buffer of 5000 and call log buffer of 1000 internal calls. Operator features shall have the assistance to extension, attended call transfer, call intercept, indication of call waiting, night service control etc. should be available by default.Make : Avaya/Alcatel/Matrix |
| 46 | SITC of Operator-cum maintenence console with large Backlit Display of 240x60 Pixels Graphic LCD, 4 Context Sensitive Keys,Built-in 16 DSS Keys,High Quality Full Duplex Speaker Phone Features Call Forward,Waiting,Transfer,Hold,Conference,Redial, Ringer Lamp.Must have storage for minimum 20 calls per call log in the console itself.Make : Avaya/Alcatel/Matrix |
| 47 | SITC of Digital DSS having 32 Direct Keys compatible with the PBX and its console.With option to add multiple DSS with the console. Phone Features Message wait Lamp, Ringer Lamp. |
| 48 | SITC of Caller ID Analog Handset with16 Digit LCD Display, Handsfree Speaker, FSK/DTMF compatible with auto detection, Incoming Call Memory of 99 Nos, Outgoing Call Memory of 18 Nos,6 One Touch Memory Keys |
| 49 | SITC of metal enclosure 100 pair mdf with copper crown |
| 50 | SITC of 10 pair telephone cable |
| 51 | SITC of 2core 1.5 sqmm power cable. MAKE:- polycab / havells / finolex |
| 52 | Supply, Carriage, erection, testing and commissioning of LED fitting with integral / non-integral driver. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from Government / NABL / UL accredited laboratory for LM79 and LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor )0.9, THD (10%. The sample of fitting can be got tested in the presence of representative of the department from NABL I UL accredited laboratory. The job includes cost of all material and erection of fitting with all accessories including anchor fasteners and connection to the nearest light point with copper wires. The work should be completed as per satisfaction of Engineer-in-charge. IP40 Batten Led fixture 4FT 40 W plus /- 1W with Surface Mounted with aluminium housing and Polycarbonate diffuser, minimum system efficacy of 110lm/W with minimum system lumens of 4400 lm with P.F.)0.95 with THD(10% ,CCT5700 K,CRI 80,Surge Protection 4 KV, IP40.The LED with Useful life of 75000 Hrs at L70. The Input voltage range shall be 150V to 270V. (Wipro Make Cat.No.LL24-541-XXX-57-XX / Havells make DURABS40WLED865SPCSS / Philips/Trilux/LT). |
| 53 | Supply, Carriage, erection, testing and commissioning of LED fitting with integral / non-integral driver. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from Government / NABL / UL accredited laboratory for LM79 and LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor )0.9, THD (10%. The sample of fitting can be got tested in the presence of representative of the department from NABL I UL accredited laboratory. The job includes cost of all material and erection of fitting with all accessories including anchor fasteners and connection to the nearest light point with copper wires. The work should be completed as per satisfaction of Engineer-in-charge. IP40 Batten Led fixture 4FT 20 W plus /- 1W with Surface Mounted with aluminium housing and Polycarbonate diffuser, minimum system efficacy of 110lm/W with minimum system lumens of 4400 lm with P.F.)0.95 with THD(10% ,CCT5700 K,CRI 80,Surge Protection 4 KV, IP40.The LED with Useful life of 75000 Hrs at L70. The Input voltage range shall be 150V to 270V. (Wipro Make Cat.No.LL24-251-XXX-57-XX / Havells make DURABS40WLED865SPCSS / Philips/Trilux/LT). |
| 54 | Supply, Carriage, erection, testing and commissioning of LED fitting with integral / non-integral driver. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from Government / NABL / UL accredited laboratory for LM79 and LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor )0.9, THD (10%. The sample of fitting can be got tested in the presence of representative of the department from NABL I UL accredited laboratory. The job includes cost of all material and erection of fitting with all accessories including anchor fasteners and connection to the nearest light point with copper wires. The work should be completed as per satisfaction of Engineer-in-charge. IP20 Batten Led fixture 2FT 10 W plus /- 1W with Surface Mounted with aluminium housing and Polycarbonate diffuser, minimum system efficacy of 100lm/W with P.F.)0.95 with THD(20% ,CCT6500 K,CRI 80,Surge Protection 2 Kv, IP20.The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 270V. (Wipro Make Cat.No.LL20-111-XXX-65AL1 / Havells make LUMILINE plus BS10WLED865SPCSS / Philips/Trilux/LT). |
| 55 | Supply, Carriage, erection, testing and commissioning of LED fitting with integral / non-integral driver. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from Government / NABL / UL accredited laboratory for LM79 and LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor )0.9, THD (10%. The sample of fitting can be got tested in the presence of representative of the department from NABL I UL accredited laboratory. The job includes cost of all material and erection of fitting with all accessories including anchor fasteners and connection to the nearest light point with copper wires. The work should be completed as per satisfaction of Engineer-in-charge. LED Foot Light Fitting 2 module in existing modular box Havells make FOOT LIGHT 3M APOGEE / Wipro / Philips make or as approved in the department). |
| 56 | Supply, Carriage, erection, testing and commissioning of LED fitting with integral / non-integral driver. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from Government / NABL / UL accredited laboratory for LM79 and LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor )0.9, THD (10%. The sample of fitting can be got tested in the presence of representative of the department from NABL I UL accredited laboratory. The job includes cost of all material and erection of fitting with all accessories including anchor fasteners and connection to the nearest light point with copper wires. The work should be completed as per satisfaction of Engineer-in-charge. 18W LED Downlighter Surface mounted round shaped Wipro make LD06-221-XXX-57 SM G1 / Philips make SM251/261 LED20S 6500 PSU WH / Havell`s make ENDURANEOHESURFACEDLS18WLED857S or its equivalent. |
| 57 | S/E of Aluminium rectangular 18x6mm LED Strip Profile Light Channel with diffuser cover, end caps and mounted clips but without LED Light. The channel is to be fixed on ceiling / false ceiling as require with the cost of all accessories. |
| 58 | Supply, Carriage, erection, testing and commissioning of LED fitting with integral / non-integral driver. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from Government / NABL / UL accredited laboratory for LM79 and LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor )0.9, THD (10%. The sample of fitting can be got tested from NABL I UL accredited laboratory by the department. The job includes cost of all material and erection of fitting in grid false ceiling / gypsum after cutting the false ceiling as required including giving support of chain from ceiling or frame including connection to the nearest light point with copper wires and petty material required to fix the fitting properly. The work should be completed as per satisfaction of Engineer-in-charge. LED downlighter in 6W plus /- 1 W LED Recess Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and HET diffuser and P.F.)0.95 ,THD(10% ,CCT 5700K, CRI 80,IP40 optical compartement with Aluminium Bottom Frame.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV. Driver. Wipro make LD06-111-XXX-57-XX / Havell`s make VIBEFLRDDLR9W LED857S / Philips/Trilux/LT |
| 59 | Supply, Carriage, erection, testing and commissioning of LED fitting with integral / non-integral driver. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from Government / NABL / UL accredited laboratory for LM79 and LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor )0.9, THD (10%. The sample of fitting can be got tested from NABL I UL accredited laboratory by the department. The job includes cost of all material and erection of fitting in grid false ceiling / gypsum after cutting the false ceiling as required including giving support of chain from ceiling or frame including connection to the nearest light point with copper wires and petty material required to fix the fitting properly. The work should be completed as per satisfaction of Engineer-in-charge. LED fixture 2`x2` Recess Mounted with PMMA diffuser with having minimum system lumen efficacy of 110 lm/W with CRCA Housing with P.F.)0.95,THD(10%,CCT 5700 K ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70. Wipro make CRCO10R038HP57GL1 / Philips make RC380B LED36S-6500 G5 L60W60 PSU OD / Havell`s make PLANO2X2PLR36WLED857S or its equivalent. |
| 60 | Supply, Carriage, erection, testing and commissioning of LED fitting with integral / non-integral driver. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from Government / NABL / UL accredited laboratory for LM79 and LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor )0.9, THD (10%. The sample of fitting can be got tested from NABL I UL accredited laboratory by the department. The job includes cost of all material and erection of fitting in grid false ceiling / gypsum after cutting the false ceiling as required including giving support of chain from ceiling or frame including connection to the nearest light point with copper wires and petty material required to fix the fitting properly. The work should be completed as per satisfaction of Engineer-in-charge. LED downlighter in 18 W plus /- 1 W LED Recess Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and HET diffuser and P.F.)0.95 ,THD(10% ,CCT 5700K, CRI 80, IP40 optical compartement with Aluminium Bottom Frame. The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2.5kV. Driver. Wipro Make LD06-221-XXX-57-XX / Havell`s make VIBEFLRDDLR18WLED857S / Philips/Trilux/LT |
| 61 | Supply, Carriage, erection, testing and commissioning of LED fitting with integral / non-integral driver. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from Government / NABL / UL accredited laboratory for LM79 and LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor )0.9, THD (10%. The sample of fitting can be got tested from NABL I UL accredited laboratory by the department. The job includes cost of all material and erection of fitting in grid false ceiling / gypsum after cutting the false ceiling as required including giving support of chain from ceiling or frame including connection to the nearest light point with copper wires and petty material required to fix the fitting properly. The work should be completed as per satisfaction of Engineer-in-charge. Supply, carriage, erection, testing and commissioning of LED strip light of wattage 15Watt per meter in existing cove of false ceiling complete with cost of driver (1 driver per five meter strip) and other accessories for indoor use of required length as per the site. (Wipro cat no. Strip : LS06-005-120-40-50 plus Driver / Havells make Strip (FLEXISTRIP5MIP2024V/2ALED865S) Driver (CVDRIVER24V2A / Philips / Trilux / LT (5mtr spool)). [For Cove Light / Profile Light]. |
| 62 | Supply, carriage, erection, testing and commissioning of LED Wall Light complete in all respect including its erection with cost of petty material required. The fitting shall be of wattage 10W to 20W and design as approved by Architect / department of Philips / Havell`s / K-Lite make. (Sample to be approved from the Client)a. Single fixture Bracket Wall Light |
| 63 | Supply, carriage, erection, testing and commissioning of LED Wall Light complete in all respect including its erection with cost of petty material required. The fitting shall be of wattage 10W to 20W and design as approved by Architect / department of Philips / Havell`s / K-Lite make. (Sample to be approved from the Client)b. Double fixture Bracket Wall Light |
| 64 | Supply, carriage, erection, testing and commissioning of LED Wall Light complete in all respect including its erection with cost of petty material required. The fitting shall be of wattage 10W to 20W and design as approved by Architect / department of Philips / Havell`s / K-Lite make. (Sample to be approved from the Client)c. LED picture wall light |
| 65 | Supply, Carriage, Erection, Testing and Commissioning of Fresh air fan 250mm complete with guard. The fresh fan is to be fixed in ventilator.The job includes connection from nearest light point with PVC Cu wire including cost of all material (ISI Marked) (Havell`s make Fresh Air fan 250mm sweep (Ventil Air DX / DX-HS) / Orient make Ventilator Fan (PB) Black 250mm or Crompton / Usha or as approved in the department. |
| 66 | Supply, carriage, erection, testing and commissioning of 380mm sweep A.C. Exhaust fan Heavy duty 900 rpm (ISI Marked Havell`s / Crompton / Orient / Usha / Bajaj make) suitable for single phase A.C. 230 Volts, 50 HZ capacitor, 900 RPM (Heavy Duty) complete with mounting ring frame with four fixing holes and automatic louver shutter but without regulator. The exhaust fan is to be fixed in the existing glazing with suitable MS frame of required thickness as per site including its painting etc. as per site requirement. |
| 67 | Supply, Carriage, Erection, Testing and Commissioning of wall fan 16` sweep (400mm) oscillating type complete with built-in regulator. The fan is to fixed on wall with suitable fixing arrangement including connection from nearest 3pin 6A socket with cost of Cu wire and 5A plug top required as per satisfaction of Engineer-in-charge. The job includes cost of all petty material required at site. Havell`s make (D’zire) / Orient 44 Azure Blue or white /Crompton make WMCressida (Light Grey) or as approved in the Haryana Police Corporation. |
| 68 | Supply, carriage, erection, testing and commissioning of 60W LED Fixtures made of Die cast aluminium housing with cast aluminium sturdy arms. Power LED’s are mounted directly on extruded Heat Sinks. A UV stabilized Clear / Frosted PMMA diffuser is provided for diffused clear finish. The fitting is to be fixed on 4m high pole / Gate Pillars including cost of all petty material required. The fitting should of Twinkle Lux Max make PT-151-03 (60W) / Havell`s make VICTORIA PT50W LED 730PSY MTOTG / K-lite or its equivalent . The work should be completed to the satisfaction of Engineer-in-charge / Architect. |
| 69 | Supply, carriage, erection, testing and commissioning of fancy steel pole 3.5mtr to 4.3mtr height complete with base plate embalishment EMB-Q4 finished with polyester / PU paint black height (Twinkle Lux Max make SP-114-402 (Z-4) / Havell`s make EROSPOLE01035M / K-Lite make KP4327 P11 or its equivalent) suitable for fancy post top lantern. The pole is to fix on existing foundation including base plate, nuts and bolts and all accessories as per manufactureer design complete with door locking arrangement. The work should be completed to the satisfaction of Engineer-in-charge / Architect. |
| 70 | Supply and erection of PVC insulated copper multistrand flexible wire 1100V grade in existing PVC conduit etc. as required from Main Panel to Various DBs. (Havell`s / Polycab / KEI or its equivalent make).4 wires of 10sqmm single core for 3 phase and neutral and 2 Nos. wires of 4sqmm single core for earths from Main Panel to various DBs. |
| 71 | Supply and erection of PVC insulated copper multistrand flexible wire 1100V grade in existing PVC conduit etc. as required from Main Panel to Various DBs. (Havell`s / Polycab / KEI or its equivalent make).4 wires of 16sqmm single core for 3 phase and neutral and 2 Nos. wires of 6sqmm single core for earths from meter panel to house DB. |
| 72 | S/F OF 55 Inch , Screen Resolution - 3840 x 2160, Brightness 350cd/m2, Inbuilt Memory 16 GB, 2GB DDR3 2133Mhz RAM, Android OS Version 9, Built in Google Play store, Screen Mirroring for Android and Windows devices, preinstalled APPs: YouTube, Netflix, etc. HDMI x 3, USB x 2, RJ45 x 1, AV IN x 1, SPDIF Out - Yes Optical, Headphone out, Viewing Angle 178/178 degree, Sound Surround Mode - Yes, Speaker output - 2 x 10W, Rated Power Consumption 150W, Standby Power Consumption 0.5W, Power Supply AC 110V – 240V. |
| 73 | S/F OF SMART LED TV 75 inch 1. RF INPUTR := 1 2. COMPANENT OUTPUT:= 1 3. SCREEN MIRRORING := YES 4. POWER CONSUMPTION := 260W 5. POWER CONSUMPT STAND BY := .05W 6. POWER SAVING MODE:= YES 7. SMAT TV:= YES 8. WIFI:= YES 9. BLUETOOTH := YES 10. SUPPORT APPS := NETFLIX,PRIME VIDEO,YOUTUBE,DISNEY plus HOTSTAR ETC 11. OTHER SMART FEATURE:=- TIZEN OS MOBILE TO TV, TV SOUND TO PHONE, SOUNDING MIRRORING, WIRELESS TV ON TAPE 12. USE PORT := 2 13. HDMI POST := 3 14. OTHER AUDIO FEATURE := 2 CHANEL SPEAKER SYSTEM ,ADAPTIVE SOUND 15. UNIVERSAL REMOTE CONTROL := YES 16. INTERNET ACCESS:= YES 17. SCREEN RESOLUTION:= 4K,3840X2160PIXL 18. DISPLAY FEATURE:= CRYSTAL PRCOESS,4K PICTURE ENGINE,1BILLION COLOR,ALLM 19. WEIGHT:- 30 TO 35 KG 20. DIMESSION :- 1673.2(W)X1050(H)X345(D) APPOX MM |
| 74 | DSR 32.2.2 Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.0 TR with 5 Star BEE Rating G.F - ROOMS (2 NOS) , F.F - ROOMS (4NOS) |
| 75 | DSR 32.2.3 Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.5 TR with 5 Star BEE Rating |
| 76 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 2.0 TR with 5 Star BEE Rating |
| 77 | Providing and fixing wall panelling with 12mm thick green make ply and finish with 4mm thick veener complete in all respect to the entire satifaction of Engineer - in - charge |
| 78 | Providing and fixing urinal partition made of frosted safety glass 8 mm thick of Model no.QU81OSC-C-STD-CR of Queo dimesnions 450x900mm. complete in all respect as per Directions of Engineer-in-Charge. |
| 79 | Providing and fixing white Vitereous- top counter wash basin rectangulare shape Queo make Model Marsala Cat No. Q257140110 size 51x41x16 cm with single lever Basin mixer with 450 mm long braided hose of Hindware make or equivalent Cat No. F280010 along Hindware make or equivalent bottle trap (Cat. No. F850003 bottle trap 32 mm with 250mm and 175 mm long wall connection pile and wall flande ), includings, cutting and making good the walls wherever require: white Vitereous- top counter wash basin rectangulare shape Queo make Model Marsala Cat No. Q257140110 size 51x41x16 cm with single lever Basin mixer. complete in all respect as per Directions of Engineer-in-Charge. |
| 80 | Poviding and fixing Single Towel Rail ( Make Jaquar FLR 5374N) or its equivalent complete in all respect 300mm long. complete in all respect as per Directions of Engineer-in-Charge. |
| 81 | Providing and fixing Soap Dish (Make Jaquar AQN 7731) or its equivalent complete in all respect as per Directions of Engineer-in-Charge. |
| 82 | Providing and fixing Paper Holder with flap Recessed Type (Stainless Steel) (Make jaquar AHS 1553) or its equivalent complete in all respect as per Directions of Engineer-in-Charge. This item is not in HSR |
| 83 | Providing and fixing CP Brass stop cock concealed of standard design and of approved make of Jaquar KUB-35083F or its equivalent. complete in all respect as per Directions of Engineer-in-Charge. |
| 84 | Providing and fixing CP Brass angle valve of approved quality Jaquar code CHR-059KN or its equivalent. complete in all respect as per Directions of Engineer-in-Charge. |
| 85 | Providing and fixing CP brass health Feccet of Jaquar make cat 573 or its equivalent complete in all respect as per Directions of Engineer-in-Charge. |
| 86 | Providing and fixing CP jali with frame heavy quality complete in all respect as per Directions of Engineer-in-Charge. |
| 87 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect. ) complete in all respect as per Directions of Engineer-in-Charge. a)110mm dia Cowel |
| 88 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect. ) complete in all respect as per Directions of Engineer-in-Charge. 110 mm dia Plain bend |
| 89 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect. ) complete in all respect as per Directions of Engineer-in-Charge. 110 mm dia Collar |
| 90 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect. ) complete in all respect as per Directions of Engineer-in-Charge. 110 mm dia Socket |
| 91 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect. ) complete in all respect as per Directions of Engineer-in-Charge. 110 mm dia P trap |
| 92 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect. ) complete in all respect as per Directions of Engineer-in-Charge. 90 mm dia Floor trap |
| 93 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect. ) complete in all respect as per Directions of Engineer-in-Charge. 90 mm dia socket |
| 94 | P/F in position of Ball valve gate valve viking make complete in all respect as per Directions of Engineer-in-Charge. |
| 95 | [10.1.1.1]Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. 1.1. Re-compacting excavated soil in plinth under floors, including watering, ramming, consolidating and dressing complete. [Through Rate] |
| 96 | [10.1]Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. [Through Rate] |
| 97 | [10.2]Supplying and filling in plinth with sand (conforming to zone-IV, IS 1542) under floors, including watering, ramming, consolidating and dressing complete. [Through Rate] |
| 98 | [10.29.1]Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 1. Light shade pigment using white cement [Through Rate] |
| 99 | [10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate] |
| 100 | [10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate] |
| 101 | [10.63.3]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mm [Through Rate] |
| 102 | [10.67.3]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm [Through Rate] |
| 103 | [10.7]Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4 [Through Rate] |
| 104 | [10.70.3]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 3. Size of Tile 800x800 mm [Through Rate] |
| 105 | [10.73]Providing and fixing ceramic and Glazed tiles/ vitrified tiles/ of any size of approved make in floors / dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands as per IS specification 15477-2004 using 5 Kg. adhesive per sqm area of tiles and jointed with white cement slurry mixed with pigment to match the shade of tiles excluding cost of tiles. [Through Rate] |
| 106 | [10.93]Providing and Laying of P.O.P on floors with polythene sheet, cleaning, wiping floor and mixing of POP with water on the polythene sheet and removing it after completion and disposing off the same complete in all respects as per direction of Engineer-in-Charge. [Through Rate] |
| 107 | [11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate] |
| 108 | [11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) [Through Rate] |
| 109 | [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 110 | [11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 111 | [11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) [Through Rate] |
| 112 | [11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate] |
| 113 | [11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate] |
| 114 | [11.77]Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. [Through Rate] |
| 115 | [11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate] |
| 116 | [11.94.1]Finishing walls with textured exterior paint of required shade : 1. New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm [Through Rate] |
| 117 | [11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate] |
| 118 | [12.1.1.3]Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid separately). 1.3. Kiln seasoned and chemically treated Hollock wood [Through Rate] |
| 119 | [12.130.1]Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 1. Frame work [Through Rate] |
| 120 | [12.130.2]Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 2. Openable shutter [Through Rate] |
| 121 | [12.136.1]Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) crescent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1. Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm up to 5.00 sqm) [Through Rate] |
| 122 | [12.157.1.3]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.3. For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) [Through Rate] |
| 123 | [12.167.3]Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge 3. Polyester powder coated minimum thickness 50 micron aluminium [Through Rate] |
| 124 | [12.171]Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). [Through Rate] |
| 125 | [12.177.1]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With toughened glass panes of 6 mm thickness (weight not less than 15 kg/sqm) [Through Rate] |
| 126 | [12.26.2]Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): 2. 18 mm thick [Through Rate] |
| 127 | [12.27.2]Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 2. 25 mm thick [Through Rate] |
| 128 | [12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate] |
| 129 | [12.37.3]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 3. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws [Through Rate] |
| 130 | [12.75.1]Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 1. 125 mm [Through Rate] |
| 131 | [12.80]Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. [Through Rate] |
| 132 | [12.86]Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. [Through Rate] |
| 133 | [12.87.2]Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 2. Double strip (horizontal type) [Through Rate] |
| 134 | [12.88]Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc. complete. [Through Rate] |
| 135 | [12.98.1]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm [Through Rate] |
| 136 | [12.98.2]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm [Through Rate] |
| 137 | [12.99.1]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 300x10 mm [Through Rate] |
| 138 | [12.99.2]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 250x10 mm [Through Rate] |
| 139 | [12.99.4]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm [Through Rate] |
| 140 | [13.23.3]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with Polyester paint of 12-16 microns thickness under coat of EPOXY primer and back coat with ALKYD backer of 5-7 microns, total sheet thickness with coating 0.58mm of approved shade, weld less corner assembly with brackets and screws, fixed in position by means of PVC and metal hold fastener with PVC cap complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge 3. Providing & fixing fixed beading 12mm x 12mm for fixed glass ECO fixed gasket (EPDM) [Through Rate] |
| 141 | [13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate] |
| 142 | [13.34]Supply and Fixing of Tensile Sheet Shed 650GSM sheet with M.S Iron pipe Frame Pole 125mm Heavy Truss M.S Pipe 60mm Heavy, Membrane M.S Pipe 50mm Heavy, Complete With cost of Painting and Labour for Fixing Paint Complete in all respects [Through Rate] |
| 143 | [13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate] |
| 144 | [17.14.3]Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix method Construction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 3. Grading III material [Through Rate] |
| 145 | [17.5.1]Compacting Original Ground 1. Compacting original ground below road crust Loosening of the ground up to a level of 500 mm below the road crust, watered, graded and compacted at OMC in layers to meet requirement of table 300-2 for embankment construction as per technical clause 305 of MORT&H specifications [Through Rate] |
| 146 | [18.7]Providing and fixing in position Phenol bonded Bamboo wood flooring with planks of sizes 14mm thick, 1800mm length (minimum) and 130 mm wide(minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials and Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded polyethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bamboo wood planks shall have minimum density of 1000 kg/cum and minimum Hardness 1000 kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge. [Through Rate] |
| 147 | [20.26.1]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall [Through Rate] |
| 148 | [20.26.2]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall [Through Rate] |
| 149 | [20.28.2]Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 2. 115 mm thickness of roof or floor [Through Rate] |
| 150 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) [Through Rate] |
| 151 | [20.71.2]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 2. 56\\" (1400mm) [Through Rate] |
| 152 | [20.89.6]`Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge.The rating should be at 1500 RPM.a) Diesel Engineb) Alternatorc) Battery 24 V.d) Base Plate.e) suitable sq mm suitable core copper cable upto 40 metres.f) Tools, standard panelg) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s)h) Metering set 60/5A/110V (Amp. Meter, Volt Meter)i) Overload protection for DC-1 No.j) Battery Charger 24V DC k)Copper bus bar of suitable sizel) KWH meter 96 sqmm sizem) Starting fuse button and key switch9on/off)n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, Dc control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge` 6. 100 KVA [Through Rate] |
| 153 | [21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping [Through Rate] |
| 154 | [21.84.2]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) [Through Rate] |
| 155 | [21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) [Through Rate] |
| 156 | [21.90.4.1]Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 4.1. On 200 mm internal diameter pipe sewer - for 1.80 meters depth below ground level [Through Rate] |
| 157 | [21.93.1]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening [Through Rate] |
| 158 | [21.94.2]Providing salt glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. 2. 150mm i/d [Through Rate] |
| 159 | [22.10.1.1]Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1.1. Kitchen sink with drain board 510x1040 mm bowl depth 250 mm [Through Rate] |
| 160 | [22.100.2]Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 2. 20 mm nominal bore [Through Rate] |
| 161 | [22.101.2.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore [Through Rate] |
| 162 | [22.102.1]Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 1. 100 mm diameter [Through Rate] |
| 163 | [22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore [Through Rate] |
| 164 | [22.105.1]Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore [Through Rate] |
| 165 | [22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate] |
| 166 | [22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate] |
| 167 | [22.14.1.1]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.1. Semi rigid pipe 32 mm dia [Through Rate] |
| 168 | [22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate] |
| 169 | [22.166.1.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.2. 100x100 mm size P type With Sewer bricks conforming to IS : 4885 [Through Rate] |
| 170 | [22.166.3.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.2. 180x150 mm size P type With Sewer bricks conforming to IS : 4885 [Through Rate] |
| 171 | [22.168.2]Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2. 150 mm dia. R.C.C. pipe [Through Rate] |
| 172 | [22.172]Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. [Through Rate] |
| 173 | [22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. [Through Rate] |
| 174 | [22.190.3.1]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 3.1. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 175 | [22.198.1]Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1. With 20x20 mm square bar [Through Rate] |
| 176 | [22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate] |
| 177 | [22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 178 | [22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 179 | [22.26.1]Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 1. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern [Through Rate] |
| 180 | [22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate] |
| 181 | [22.36.1]Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : 1. White solid plastic seat with lid [Through Rate] |
| 182 | [22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. [Through Rate] |
| 183 | [22.81.1]Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1. 100 mm dia [Through Rate] |
| 184 | [22.85.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate] |
| 185 | [22.85.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate] |
| 186 | [22.85.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate] |
| 187 | [22.85.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 6. 50 mm nominal outer dia Pipes [Through Rate] |
| 188 | [22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate] |
| 189 | [22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate] |
| 190 | [22.96.1]Providing and fixing brass bib cock of approved quality : 1. 15 mm nominal bore [Through Rate] |
| 191 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate] |
| 192 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 193 | [23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP [Through Rate] |
| 194 | [23.22.4.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing) [Through Rate] |
| 195 | [23.22.4.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] |
| 196 | [23.22.4.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate] |
| 197 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 198 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] |
| 199 | [23.23.8.1]MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire [Through Rate] |
| 200 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 201 | [23.24.4.2]MS STAND, BUS BAR CHAMBER AND PANELS 4.2. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 250 amp. [Through Rate] |
| 202 | [23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. [Through Rate] |
| 203 | [23.27.3]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate] |
| 204 | [23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 205 | [23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate] |
| 206 | [23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 207 | [23.3.6.8]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.8. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 208 | [23.4.1.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C [Through Rate] |
| 209 | [23.4.2.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.3. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C [Through Rate] |
| 210 | [23.4.3.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.3. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group C [Through Rate] |
| 211 | [23.4.4.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C [Through Rate] |
| 212 | [23.4.5.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C [Through Rate] |
| 213 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 214 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 215 | [23.7.6.3]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. [Through Rate] |
| 216 | [23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. [Through Rate] |
| 217 | [23.8.1.12]FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. [Through Rate] |
| 218 | [23.8.1.5]FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type [Through Rate] |
| 219 | [23.8.1.6]FITTING AND ACCESSORIES 1.6. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type [Through Rate] |
| 220 | [23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate] |
| 221 | [23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules [Through Rate] |
| 222 | [23.8.10.4]FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules [Through Rate] |
| 223 | [23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate] |
| 224 | [23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate] |
| 225 | [23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type [Through Rate] |
| 226 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate] |
| 227 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate] |
| 228 | [23.8.11.8]FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type [Through Rate] |
| 229 | [23.8.11.9]FITTING AND ACCESSORIES 11.9. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. T.V. Socket outlet modular type [Through Rate] |
| 230 | [23.8.2.2]FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick [Through Rate] |
| 231 | [23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate] |
| 232 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 233 | [24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. [Through Rate] |
| 234 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 235 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 236 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 237 | [24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate] |
| 238 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 239 | [24.13.12]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 12. 6 Sq mm 4 core (Arm.) [Through Rate] |
| 240 | [24.13.62]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95 Sq mm 3.5 core (Arm.) [Through Rate] |
| 241 | [24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate] |
| 242 | [24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core [Through Rate] |
| 243 | [24.2.8.2]LT CABLE 8.2. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 4 sqmm to 6 sqmm [Through Rate] |
| 244 | [24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm [Through Rate] |
| 245 | [24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm [Through Rate] |
| 246 | [24.4.5]STREET LIGHT 5. Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections. [Through Rate] |
| 247 | [24.4.6]STREET LIGHT 6. Supply and erection of Three Phase weather proof M.S. box of size 30 cm x 20 cm x 15 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 16 amp TP MCB and 4 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box and necessary connections. [Through Rate] |
| 248 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 249 | [24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia [Through Rate] |
| 250 | [24.7.3]RCC FOUNDATIONS FOR DG SET 3. 100 KVA DG Set [Through Rate] |
| 251 | [24.8.2]RCC FOUNDATIONS FOR OCTAGONAL POLES 2. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 4m high pole [Through Rate] |
| 252 | [26.2]Supplying and stacking of good quality top layer garden earth free from debris and weeds, at site including royalty and carriage/lead 5 km (good earth measured in stacks will be reduced by 20 % for payment) only for filling of pots and flower beds . 0.00 0.00 0.00 [Through Rate] |
| 253 | [26.269]Providing and Displaying Acalypha Different colour well developed, fresh and healthy with good foliage, multi branch 30 to 45 cm ht. in 15 cm size of Earthen Pot/ Plastic Pot bushy plant as per direction of the officer-in-charge. [Through Rate] |
| 254 | [26.280]Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh and healthy bushy plant in full bloom 75 to 90 cm ht. in 35 cm Cement Pot as per direction of the officer-in-charge. [Through Rate] |
| 255 | [26.34]Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth, mixed with farm-yard manure, supplied at the rate of 1.62 cum per 18 sqm, DAP 0.6kg, Chlorpyriphos 20%EC@ 0.20 litre per 18 sqm and supplying and planting hedge at 30 cm apart in two rows @ 202 no. well trimmed bushy ,multi-branched ,30 cm to 45 cm in height plants to be supplied in 15 cm x 15 cm poly bags per 18 sqm . [Through Rate] |
| 256 | [26.35]Maintaining the hedges for one year including watering, hoeing weeding trimming and shaping ,replacement of casualty as and when noticed, application of Farm yard manure @ 0.0127 m layer over surface, application of insecticide chlorpyriphos @ 2ml per sqm twice , urea @40gm and DAP @10 gm per sqm once in a year. [Through Rate] |
| 257 | [26.350]Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. [Through Rate] |
| 258 | [26.355]Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 30-40 cm well developed in big HDPE bags as per direction of the officer-in-charge. [Through Rate] |
| 259 | [26.359]Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. [Through Rate] |
| 260 | [26.387]Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 25-30 cm well developed in big size HDPE bags as per direction of the officer-in-charge. [Through Rate] |
| 261 | [26.418]Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. [Through Rate] |
| 262 | [26.420]Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. [Through Rate] |
| 263 | [26.426]Providing and stacking of Eugenia jambolana (Jamun) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. [Through Rate] |
| 264 | [26.428]Providing and stacking of Tamarindus indica (Imli) of height 120-150 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. [Through Rate] |
| 265 | [26.440]Providing and stacking of Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. [Through Rate] |
| 266 | [26.446]Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge. [Through Rate] |
| 267 | [26.456]`Providing and stacking of Ficus blackii (F.vivion) (bushy) of height 150-165 cm. with 8-10 branches and healthy foliage in earthen pots of size 30 cm as per direction of the officer-in- charge.` [Through Rate] |
| 268 | [26.46]`Supplying and display specimen pot plant of raphis palm , cephorthia palm 150 cm,areca palm 150-180 cm and similar high quality plants of croton petra 3 plants each in 45 cm plastic pots with plastic plate for indoor display at site of work. with fresh foliage,90 cm- 180 cm in height` 6-8 stems per pot, full of leaves, ,and displaying indoor including the cost of material ( garden soil, coco peat,FYM in 2:1:1 proportion),with ,PVC plate. complete in all respects.` [Through Rate] |
| 269 | [26.47]Maintenance of indoor specimen potted plants in 45 cm plastic pot/ earthen pot/ cement pot for one year including watering, application of fertilizer NPK 20:20:20 @30 gm and vermi compost 100 gm twice , manure, snowcem/ apex every month, replacement of pot plate, replacement of 30% pots every year with same quality plant , dead plant with same specie of plant etc. [Through Rate] |
| 270 | [26.48]Supplying decorative plant in 30 cm cement pots for outdoor display at site of work with fresh foliage of 60cm-75 cm in height` 3-4 stems per pot, full of leaves, suitable for earthen pots / plastic pots size 30cm dia and 30cm deep(average size) and displaying including the cost of material ( garden soil, coco peat, FYM in2:1:1 proportion),with ,PVC plate. complete in all respects. [Through Rate] |
| 271 | [26.49]Maintenance of outdoor potted plants in 30 cm earthen / cement pot for one year including watering, application of fertilizer NPK 20:20:20 @20 gm ,and vermi compost 50 gm , manure, snowcem/ apex every month, replacement of pot plate, broken pot, dead plant with same specie of plant etc. [Through Rate] |
| 272 | [26.512]Providing and stacking Bignonia venusta (Golden shower) of height 30 cm to 45 cm. in 20 cm size of Polybag and as per direction of the officer-in-charge. [Through Rate] |
| 273 | [26.513]Providing and stacking Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara, Mohan, Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Polybag and as per direction of the officer-in-charge. . [Through Rate] |
| 274 | [26.517]Providing and stacking Jasmine grandiflorum (chameli) of height 30 cm to 45 cm. in 20 cm size of Polybag and as per direction of the officer-in-charge. . [Through Rate] |
| 275 | [26.58.2]Supply and installation of garden bench 2. Rectangular garden bench with h-shaped sides made of reinforced concrete (M30), thickness 100 mm, back height 750 mm, base width 450 mm. Back and seat shall consist of rectangular reinforced concrete planks 1500 mm x 350 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation. All materials required to be as per BIS specifications. [Through Rate] |
| 276 | [26.71.1]Supply and installation of pop up sprinklers 1. Pop up Impact Rotors 3/4\\" inlet and radius ranging from 7-12 m with interchangeable nozzles with check valve and all accessories complete as per BIS standard specifications and setting flow rate as directed. [Through Rate] |
| 277 | [26.76]Providing and fixing pair of Plastic dustbins 100 litre volume each, of two different colours, for dry and wet waste, made of virgin plastic to be mounted on MS rectangular hollow section 50 x 25 x 3 mm frames pivoted on 3 MS square hollow section verticals, 1 m above ground, one 35 cm RHS welded to each vertical member at base and grouted in 180 x 40 x 30 cm 1:2:4 cement concrete. [Through Rate] |
| 278 | [26.9.1]Turfing lawns with fine grassing ( selection no.1/ Bermuda and Mexican/Neelgiri grass )including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying of selection no. 1 / Bermuda doob grass and Mexican/Neelgiri grass roots, including supplying and spreading of farmyard manure at the rate of 0.60 cum per 100 sqm, maintenance till weed free turf is formed 1. Planting selection no. 1 grass roots in rows 5 cm apart in both directions . [Through Rate] |
| 279 | [33.12]Supplying, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 280 | [33.13]Supplying, filling, spreading and levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 281 | [33.14]Supplying, filling, spreading and levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge. [Through Rate] |
| 282 | [33.18.3]Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 3. 200 mm dia [Through Rate] |
| 283 | [33.19]Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `V` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge. [Through Rate] |
| 284 | [33.6.1.3]Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 1.3. All types of soil 400 mm dia [Through Rate] |
| 285 | [33.8.3]Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 3. 200 mm nominal size dia [Through Rate] |
| 286 | [33.9.3]Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 3. 200 mm nominal size dia [Through Rate] |
| 287 | [4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate] |
| 288 | [4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate] |
| 289 | [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate] |
| 290 | [4.33]Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. [Through Rate] |
| 291 | [4.39]Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% [Through Rate] |
| 292 | [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 293 | [6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 294 | [6.10]Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. [Through Rate] |
| 295 | [6.13]Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. [Through Rate] |
| 296 | [6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate] |
| 297 | [6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate] |
| 298 | [6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate] |
| 299 | [6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate] |
| 300 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] |
| 301 | [6.30.4]Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) [Through Rate] |
| 302 | [6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate] |
| 303 | [6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate] |
| 304 | [6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases [Through Rate] |
| 305 | [6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate] |
| 306 | [6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate] |
| 307 | [6.39.1]Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 308 | [6.9.1]Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) 1. 50 mm thick [Through Rate] |
| 309 | [7.21.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 310 | [7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 311 | [7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) [Through Rate] |
| 312 | [7.56]Dressed or moulded three brick cornice laid in cement sand mortar 1:4 including 12 mm thick cement plaster 1:4 or pointing, as required. [Through Rate] |
| 313 | [8.17]Providing and fixing manufactured jali of reinforced cement concrete consisting of cement , coarse sand and 10mm and down gauge bajri in ratio of 1:1:2 with 8mm dia tor steel. Outer frame of the jail will be 50mm wide and 25mm thick and inner frame of jali will be 25mm wide and 25mm thick with smooth finish as per design approved by the Engineer-in-Charge including fixing in position up to any height with cement sand mortar 1:4 complete in all respect. [Through Rate] |
| 314 | [8.26.2.2]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shade Area of slab over 0.50 sqm [Through Rate] |
| 315 | [8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work [Through Rate] |
| 316 | [8.28]Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. [Through Rate] |
| 317 | [9.10.1]Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 1. With residual type petroleum bitumen of grade VG -10 [Through Rate] |
| 318 | [9.11.1]10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 [Through Rate] |
| 319 | [9.14.1]Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 1. With common burnt clay non-modular brick tiles of class designation 10 [Through Rate] |
| 320 | [9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate] |
| 321 | [9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate] |
| 322 | [9.46.1]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 1. 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) [Through Rate] |
| 323 | [9.47.1]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 1. GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. [Through Rate] |
| 324 | [9.48]Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. [Through Rate] |
| 325 | [9.52.1]Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class Kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 1. Flat surfaces [Through Rate] |
| 326 | [9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate] |
| 327 | [9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend [Through Rate] |
| 328 | [9.58.6.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.2. Shoe (Plain) 110 mm Shoe [Through Rate] Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail