| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected: All kinds of soil : |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 7 | Extra for brick work with common burnt clay bricks/cement concrete bricks insuperstructure above plinth level upto floor five level |
| 8 | Half brick masonry with common burnt clay (non-modular) bricks of class designation7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 9 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 10 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Cold twisted bars. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platforms. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for:Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, pillars, piers, abutments, posts and struts. |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form work for:Under 20 cm wide |
| 18 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 19 | 15mm Cement plaster on the rough side of single or half brick wall ofmix: 1 : 4 ( 1 cement : 4 fine sand) |
| 20 | 6MM CEMENT PLASTER6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 21 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 22 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece. |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 25 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. completeSize of tile 600x600 mm |
| 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 27 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 28 | Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete. |
| 29 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 30 | Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge:19.1.1 Internal work-exposed on wall with clamps at 1.00 meter spacing 1216 (16mm OD) pipe |
| 31 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.: Internal work-Exposed on wall 20 mm dia. nominal bore |
| 32 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes 110 mm diametre |
| 33 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore |
| 34 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 35 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. Rectangular shape 600x450 internal dimensions |
| 36 | Providing and fitting of electric motor of 1 HP water pump /motor of make ISI marked,including fitting complete job as per the direction of Engineer incharge complete job |
| 37 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mmnominal size well rammed and consolidated and grouted with fine sand including finishingthe top smooth and curing complete |
| 38 | Providing and fixing CP Gratting 100 MM Dia. complete job as per the directions of the engineer in charge |
| 39 | Providing and Fixing UPVC Flow Trap 110 mm complete job as per the directions of the engineer in charge |
| 40 | 15mm cement plaster on the rough side of single or half brick wallfinished with a floating coat of neat cement of mix :1 : 4 ( 1 cement : 4 fine sand) |
| 41 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 |
| 42 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brassm pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :White Vitreous China Wash basin size 630x450 mm with asingle 15 mm C.P. brass pillar taps. |
| 43 | Providing and fixing of Inaguration Plate of size 3'-0 x2'-6 of Granite Marble stone of Black colour with carving letters (Complete Job) |
| 44 | Providing and fixing uplasticized PVC connection pipe with brass unions 15 mm nominal bore |
| 45 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 |
| 46 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mmhigh and 112 mm distance from wall of standard shape with brackets ofthe same materials with snap fittings of approved quality and colour,weighing not less than 105 gms. |
| 47 | Providing and fixing of internal electric fitting incl. Lights and conduits G.I Box and other fittings with wiring as per the direction of Engineer-in-Charge Complete Job Switch Boards incl. Pianao Switches wiring Labour all Complete |
| 48 | Providing and fixing service line (Alluminium 10 sqm mm x 2 core ) complete Job |
| 49 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 50 | Carriage of material Sand and Stone Aggregate 20 mm From Source to site of work Average 10KM by MT. including loading , unloading and stacking complete. |
| 51 | Carriage of Stone Aggregate above 40 mm in nominal size av. 10 km by MT from source to site of work including loading , unloading and stacking complete. |
| 52 | Carriage of Bricks av. 15 km by MT from source to site of work including loading , unloading and stacking complete. Please Enable Macros to View BoQ information |