| 1 | Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, modular type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 2 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, MODULAR type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 3 | Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire and MODULAR type switches & socket etc., complete in all respects as directed, including matching color wash. |
| 4 | Addition when modular type switches etc are used in place of piono type switches etc various wiring points. |
| 5 | Addition for light/fan points with modular type switch in place of piono type switch. |
| 6 | Addition for plug points with modular type switch in place of piono type switch. |
| 7 | Addition for Exhaust fan points with modular type switch in place of piono type switch. |
| 8 | Supply & wiring of submains with 2 number 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. |
| 9 | Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 4.0 Sqmm FRLSH PVC Multistand copper earth contunity wire including colour wash etc. complete in all respects. |
| 10 | Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 4.0 Sqmm FRLSH PVC Multistand copper earth contunity wire including colour wash etc. complete in all respects. |
| 11 | Supply and wiring of submain with 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 32 mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects. |
| 12 | Supply and wiring of submain with 4 number 25 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 32 mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects. |
| 13 | Supply & fixing and concealing of 20mm dia 2mm thik pvc conduit pipe with isi mark embosed and with PVC acessories Cost of Material labour and T &P etc recq. For proper completion of work (For Telephone) |
| 14 | SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS UPPWD-2018 |
| 15 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 16 | Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. |
| 17 | S/F HEXAGONAL/ROUND G.P fan box of approved make made up of1.0mm thick ISI marked G.P sheet spot weeldeed four to eigth hole of 25.4mm for pipe........ T&p etc required for proper completion of the work |
| 18 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. |
| 19 | BEE 5 STAR RATED-1200MM SWEEP |
| 20 | S/F OF electronic fan regulator 120-280 V. ISI marked, on the existing switch board included making connection ,labour T/P etc for suitable for surface complete in all respect(CAT:AAA) |
| 21 | Supply and Fixing of LED Tube Light with batten suitable for up to 2X22 watt LED tube light fitting complete including tube on surface complete in all respect. |
| 22 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. |
| 23 | S/F of recess/surface mounting round 10 to15 watt,cut out min 125mm,height min 40mm,led down lighter having powder coated die cast Al housing with heat sink respect (CAT:AAA) |
| 24 | Total Of SUB - HEAD II (UPPWD-2018) |
| 25 | SUBHEAD III - DISTRIBUTION BOARD UPPWD-2018 |
| 26 | Supply and fixing of surface/ flush mounting 6 way TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer Incharge. |
| 27 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve 6- 32 amps.Cat. A |
| 28 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) CAT A |
| 29 | Supply and fixing of 40 Amp. 4 Pole MCB (10KA) CAT A |
| 30 | Supply and fixing of surface/ flush mounting 4 way TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer Incharge.CAT A |
| 31 | S/F and making connection of following MCCBS Complete in all respect as per direction CAT.A |
| 32 | 125 Amp. FP MCCB (Cat:A) |
| 33 | S/F and making connection of following MCBS Complete in all respect as per direction CAT.A |
| 34 | 63Amp TP MCB (CAT:A) |
| 35 | 40Amp TP MCB (CAT:A) |
| 36 | Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. |
| 37 | Supply & fixing of Sheet Steel Enclosure Surface/ Flush Mounting fitted With 20/32 Amp. 2Pin and earth metal clad scraping earth plug and socket complete in all respects as per direction and satisfaction of engineer-in-charge. |
| 38 | Supply and fixing of single pole MCB blanking plate |
| 39 | Total Of Sub-Head III (UPPWD-2018) |
| 40 | SUBHEAD IV-EARTHING UPPWD-2018 |
| 41 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accesMRies, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 42 | Supplying and laying 25 mm X3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 43 | S/f of two number 8SWG G.I.wire in 15mmdia GI pipe for earthing purpose as recquired complete in all respects |
| 44 | Total Of Sub-Head IV (UPPWD-2018) |
| 45 | subhead v-cables |
| 46 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 47 | 50 sqmm 3.5 core |
| 48 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed |
| 49 | 50Sqmm 3.5 core |
| 50 | supply and fixing of palm/ pin type copper tin plated cable sockets (lugs) to the cable leads insulating with tape making |
| 51 | 50 sqmm |
| 52 | 25 sqmm |
| 53 | subhead VI Miscellaneous |
| 54 | Non Sch. |
| 55 | Supply of AC 230/250 Volts, 50htz exhaust fans including providing nuts, bolts mouting frame |
| 56 | 300mm sweep |
| 57 | supply & errection of turbo ventilator (Alumium) |
| 58 | Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, modular type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 59 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, MODULAR type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 60 | Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire and MODULAR type switches & socket etc., complete in all respects as directed, including matching color wash. |
| 61 | Addition when modular type switches etc are used in place of piono type switches etc various wiring points. |
| 62 | Addition for light/fan points with modular type switch in place of piono type switch. |
| 63 | Addition for plug points with modular type switch in place of piono type switch. |
| 64 | Addition for Exhaust fan points with modular type switch in place of piono type switch. |
| 65 | Supply & wiring of submains with 2 number 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. |
| 66 | Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 4.0 Sqmm FRLSH PVC Multistand copper earth contunity wire including colour wash etc. complete in all respects. |
| 67 | Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 4.0 Sqmm FRLSH PVC Multistand copper earth contunity wire including colour wash etc. complete in all respects. |
| 68 | Supply and wiring of submain with 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 32 mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects. |
| 69 | Supply and wiring of submain with 4 number 25 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 32 mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects. |
| 70 | Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. |
| 71 | Supply and Fixing of LED Tube Light with batten suitable for up to 2X22 watt LED tube light fitting complete including tube on surface complete in all respect. |
| 72 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. |
| 73 | S/F of recess/surface mounting round 10 to15 watt,cut out min 125mm,height min 40mm,led down lighter having powder coated die cast Al housing with heat sink respect (CAT:AAA) |
| 74 | Total Of SUB - HEAD II (UPPWD-2018) |
| 75 | SUBHEAD III - DISTRIBUTION BOARD UPPWD-2018 |
| 76 | Supply and fixing of surface/ flush mounting 6 way TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer Incharge. |
| 77 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve 6- 32 amps.Cat. A |
| 78 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) CAT A |
| 79 | Supply and fixing of 40 Amp. 4 Pole MCB (10KA) CAT A |
| 80 | Supply and fixing of surface/ flush mounting 4 way TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer Incharge.CAT A |
| 81 | S/F and making connection of following MCCBS Complete in all respect as per direction CAT.A |
| 82 | 125 Amp. FP MCCB (Cat:A) |
| 83 | S/F and making connection of following MCBS Complete in all respect as per direction CAT.A |
| 84 | 63Amp TP MCB (CAT:A) |
| 85 | 40Amp TP MCB (CAT:A) |
| 86 | Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. |
| 87 | Supply & fixing of Sheet Steel Enclosure Surface/ Flush Mounting fitted With 20/32 Amp. 2Pin and earth metal clad scraping earth plug and socket complete in all respects as per direction and satisfaction of engineer-in-charge. |
| 88 | Supply and fixing of single pole MCB blanking plate |
| 89 | Total Of Sub-Head III (UPPWD-2018) |
| 90 | SUBHEAD IV-EARTHING UPPWD-2018 |
| 91 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accesMRies, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 92 | Supplying and laying 25 mm X3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 93 | S/f of two number 8SWG G.I.wire in 15mmdia GI pipe for earthing purpose as recquired complete in all respects |
| 94 | Total Of Sub-Head IV (UPPWD-2018) |
| 95 | subhead v-cables |
| 96 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 97 | 50 sqmm 3.5 core |
| 98 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed |
| 99 | 50Sqmm 3.5 core |
| 100 | supply and fixing of palm/ pin type copper tin plated cable sockets (lugs) to the cable leads insulating with tape making |
| 101 | 50 sqmm |
| 102 | Non Sch. |
| 103 | Supply of AC 230/250 Volts, 50htz exhaust fans including providing nuts, bolts mouting frame |
| 104 | 300mm sweep Please Enable Macros to View BoQ information |