| 1 | S/F of 6 Amp. To 32 Amp. SP MCB (10KA) C curve Cat-B as per UPPPWD sch No1002 |
| 2 | S/F of heavy duty cadmium plated copper connector with end plate complete in all respects (c) four way connector HKM 100 as per UPPPWD Sch. No. 1128 |
| 3 | Supply & Erection of 8 Mtr. Long GI Octogonal Pole of Approved make having (70mm top dia, 135 mm bottom dia,base plate 12 mm thick) having 3 mm thickness with single arm bracket (1 Mtr. length) on RCC foundation including the cost of foundation, foundation bolts ,excavation & back filling and required T&P complete in all respect as per PWD Sch. No. 643 as per approved make |
| 4 | S/F of crimping, solderless copper tin electroplated lugs of Dowells/Ismail make suitable for 1.5 sq mm to 6 sq. mm cables, including tapping with insulating tape complete in all respects as per UPPWD sch. No. 1129 |
| 5 | Supply & wiring of submain with 3 Nos. of 2.5 sqmm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cables in existing conduit complete with supply of all material labour and T&P reuired for proper complation of the work as directed as site by Engineer I/C as Per UPPWD sch No. 289 (KEI/ Havells/ Grandley/gloster/Polycab Make ) |
| 6 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer - incharge as per UPPWD sch. no. 503 (I) 16 sq. mm 4 core |
| 7 | S/F ofpalm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (d) 16 sq. mm |
| 8 | S/B of 40 mm dia x 4.5 mtr. Long GI pipe vertical for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. From the bottom complete with earthing lead of no. 6 to 8 SWG GI wire in GI pipe upto appron upto switch board 30 CM square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect as per drawing as per UPPWD Sch. No. 701 |
| 9 | S/F of M.S Earthing rod (2500x20mm) in verticaly ground level and connecting the pole with the help of 6SWG GI Wire/25mm X 3mm including cost of all material men and T&P |
| 10 | Supply and laying of 25 mm x 3mm G.I. strip from earth electrode directly in the ground as required respects as per UPPWD Sch. No. 716 |
| 11 | Supply & Erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuse and The instrument chamber shall be separate and shall comprise of flush type ammeter,voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc complete in all respects. (Incoming 100 Amp., TPN-1 No. & outgoing 63 Amp. TPN-2 Nos.. as per UPPWD Sch. No. 801-a-II |
| 12 | Supply and fixing 25amp. TPN Capacity of high mast cubicle control panel painted with astronomical clock,Anti corosive alkali and acid proof paint, consisting of time switch TSO 100 serices/ Digital with ML-4 Contractor, HRC Fuses Isolating switch, metering Instrument & Instrument box with C.T. etc. Complete in all respect's.as per UPPWD Sch. No.807e (ii) |
| 13 | Supply and fixing of 200 watt factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for confirming to IP 66 protection complete in all respects. Make as per direction of the Engineer- incharge Catt. AA as per UPPWD Sch. No.1455 (Bajaj, crompton, Philips, Wipro Make) |
| 14 | Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. make as per direction of the Engineer- incharge as per UPPWD Sch. No.652, (Bajaj, crompton, Philips, Wipro Make) |
| 15 | Supply&Fixxing of of UPSIDA LOGO Plate (Retro-reflective) on High Mast including cost of clamp nut & bolts all material men and T&P complete in all respect |
| 16 | Supply and laying of aluminium conductor PVC insulated, armoured, served, sheathed cable 1100 V grade at a depth of 750 mm below ground level in existing HDPE/DWC/GI Pipe complete in all respects (KEI/ Havells/ Grandlay/Gloster/Polycab Make ){as per PWD Sch. No. 501(i) - Sch No. 507} 16 sq.mm 4 core (343-170 = 173 Rs.) |
| 17 | Supply, installation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.433 KV complete as per IS-1180-2014 Level-I as per approved list of UPPCL |
| 18 | Supply and fixing of 11KV TPMO Switch of 400 amps. Copmlete in all respect as per direction of Engineer in charge complete incuding all T&p, men and material required for proper completion.UPSIDC 35.28 |
| 19 | S/F of 11 kV three phase D.O. fuse set complete with suitable clamps, nuts & bolts, fuse wire etc. |
| 20 | Supply and erection of Double Pole structure consisting of 410-SP-55,11m long 227 Kg complete steel tubular pole (G.I. Bottom) to be grouted as 1/6th of overall length below ground level with 45 cm dia cement concrete plinth around the pole & 45 cm above the ground level. The foundation of underground will not be less than 20 cm thick layer of cement concrete in the ration of 1:3:6 ( cement : coarse sand : over burnt brick ballast/stone ballast). The brick ballast / stone ballast will be used of 1.25 cm size with stone pad of 30X30X7.5 cm at the base. The cost includes all men and material.UPSIDC schedule No E04A.1.I |
| 21 | Supply and fixing of 11 KV ordinary pole fitting with guarding Channel 2.24 M long instaed of Z clamps including all T&P,men and material for proper completion of work as per SIDC schedule no E03.02 |
| 22 | Supply and fixing of 11KV Disc fitting complete UPSIDC schedule no E03.06 |
| 23 | Supply and fixing of 11KV pin insulator complete UPSIDC schedule no E03.06 |
| 24 | Supply & fixing of danger board fabricated from 10 gauge MS sheet as approved by engineer in charge complete in all respect as per SIDC Sch.No.E27.02 |
| 25 | Supply & erection of stay of Composite mains for ST pole with GI anchor plate (152X152X6mm) stay rod (16mm dia X 1.85 m Iong),GI stay bow (16 mm dia rod,thimble,double stay tightener,clamps & stay wire (GS 7/3.15 mm) including grouting in 1:4:8 ratio of cement concrete using coarse sand,over burnt brick ballast as per direction of engineer in charge complete in all respect as per SIDC sch.No E32.01 |
| 26 | Supply and fixing of anticlimbing device fabricated from G.I. flat of 25 mmX6 mm size in a shape of ring of the pole size,having G.I.flat pointed fins of length 225 mm in 8 nos and also barbed wire in 200 mm length above the said ring including material. UPSIDC E26.01 |
| 27 | supply & Fixing of Tiranga LED light strip with tiranga colour light complete with driver etc.complete in all respect . warranty one years, ( Philips, Bajaj, Crompton, Wipro Make) |
| 28 | Supply & Fixing of 4.0 Mtr. long Decorative Ornamental Pole duly PU (Poly Urethane) Painted made of high tensile GI Steel Pipe. The Top section of pole must have Cast Aluminum Embellishments through out the length. Base Plate size 200x200x10mm with PCD of 200mm. Foundation bolts set of M16x450mmx 4 Nos made of EN8 grade steel should be used only for erection. A lockable door of suitable size should be provided at bottom section for termination and connection with backelite sheet and connector, MCB etc. on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P. Bottom dia-150mm up to 1200mm height from base plate. Top section dia-60mm & tolerance as per IS code or approved by engineer in charge. |
| 29 | Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect with 5 years warranty. Technical specification, make & profile as approved by engineer in charge.CAT AA |
| 30 | Spray Painting of ST pole and all mountings on it with two coats of aluminium paints with an under coat of red oxide paint upto10 M. support above the ground level as per direction of Engineer in-charge of work/site including T&P , men & material required for proper completion of work UPSIDC Sch No 24.20 (A) |
| 31 | Tree Branches Triming for removing dark spots including cost of all material men and T&P complete in all respect rates. |
| 32 | Supply and fixing of LED street light fitting having diming controller with smart control set suitable for 120 Watt confirming to IP 65 and bove protection complete in all respect. |
| 33 | Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 graded stone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size complete in all respect. |
| 34 | Supply and erection of steel tubular pole 410-SP-61, 12 Mtr long, 245 Kg complete with 1/6th of overall length of pole below ground level with 45 cm dia cement concrete with 45cm dia cement plinth around the pole and 45cm above the ground level.The foundation of underground will not be less than 20 cm thick layer of cement concrete in the ration of 1:2:4 ( cement : coarse sand : over burnt brick ballast/stone ballast). The brick ballast / stone ballast will be used of 1.25 cm size with stone pad of 30X30X7.5 cm at the base. The cost includes all men and materials.including C.I. Cap UPSIDC Sch No. E02.06A |
| 35 | Supply & laying of 160 mm dia (OD-160 mm & ID-136 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc.confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete in all respect .(pwd 1.16.4) |
| 36 | Supply & laying of 120 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc.confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete in all respect .(pwd 1.16.3) |
| 37 | S/Laying of 200 mm dia MS pipe ISI marked 6 mm thick as per IS 2062 grade Fe-400 including welding etc.complete laying with Bogi method , cost of all T&P men & material for proper completion of work complete in all respect. |
| 38 | S/L of 185 Sq.mm, 3 core standard aluminium conductor XLPE (cross linked polyethylene) insulated PVC bedded glavanised flat steel strip armoured cables confirming to IS 7098 (Part-II) with latest amendments, 11 KV grade at a depth of 900 mm below ground level. The armouring of cable shall be properly connected with earth conductor by clamp etc.(Polycab/Gloster/KEI /Havells/Grandlay make) (185 sq. mm 3 core cable) (When cable is passed through pipe) |
| 39 | S/F of outdoor/indoor type 11 KV jointing kit heat shrinkable type for 11 KV cable including cost of all material, labour, T&P etc. for proper completion of work. (Raychem/Denson/Birla /3M make) for 3 x 185/70 sq.mm cable. |
| 40 | Supply & fixing of 11 KV straight through jointing kit heat shrinkable type for 11 KV cable including cost of all material,labour, T&P etc. for proper completion of work (Raychem/Denson/Birla/3M make) for 3 x 185 sq.mm cable. |
| 41 | Supply,sagging,tensioning,jointing and binding of ACSR Dog conductor including cost of aluminium tape binding wire and jointing sleeves complete in all respects including materiaI,men an T&P for proper completion of work UPSIDC schedule No E10.08 |
| 42 | Supply,sagging,tensioning,jointing and binding of insulated ACSR weasel conductor including cost of aluminium tape binding wire and jointing sleeves complete in all respects including materiaI,men an T&P for proper completion of work complete in all respect. |
| 43 | Supply & sagging,tensioning,jointing,binding two parallel length of G.I. no. 6 SWG wire along the span and G.I. no. 6 SWG wire across the span each at an interval of 5m for cross lacing complete as per direction of engineer-in-charge as per SIDC schedule E12.01 |
| 44 | Supply & fixing of clamp suitable for securing the above channel 100x50 mm/75/40 mm complete as per SIDC Sch.No.3(4) |
| 45 | Supply and fixing of 100 mm dia G.l.pipes B,class for climbing up the cable from ground to over head line including all accessories,materiaIs,labours and T&P required for proper completion of work as per specification SIDC schedule No E25.01 |
| 46 | Supply & laying 120 sq mm 3.5 core Al. conductor PVC insulated armoured, served, sheathed cable 1100 V garade in The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(r) & 507 |
| 47 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (J) 120 sq. mm |
| 48 | Fabrication,Supply & Fixxing of work information board in M.S frame made by 50 mm dia sqaure pipe of stainless steel grade SS-304 &16 mm thick base plate with back supporting of bracing by MS flat of 25x6 mm and 2.85 Mtr. Long supporting leg made from 65mm pipe SS-304 grade with proper grouting arrangement. The board should be Retro reflective type in green colour with white letters as required and shall be fixed at a height of 1.2 Mtr. from ground by providing 0.45x0.45x0.60 Mtr. cement concrete stone pad |
| 49 | Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021 (11KV भूमिगत केबल ) |
| 50 | Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paint of approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P. |
| 51 | S/F of following capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint consisting of timert switch TSO 100 series/digital with ML-4 Contractor,HRC Fuses,isolating switch metering instruments box CTS etc. as per PWD sch No 807 F (40 Amp TPN ) |
| 52 | Supply & laying 70 sq mm 3.5 core Al. conductor XLPE insulated PVC bedded galvanised flat steel strip armoured, served, sheated cable 1100 V garade in existing HDPE pipe laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 506 (d) (915-170 =745) (KEI/ Havells/ Grandle/gloster/Polycab Make ) |
| 53 | Supply and laying of ISI marked alluminium conductor FR XLPE insulated cable as per IS 7098 &Cable armoured served sheathed 1100 V grade 10 sqmm 4 core (as per UPPWD approved make list) |
| 54 | S/F ofpalm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (d) 10 sq. mm Please Enable Macros to View BoQ information |