|
| 1 | Raising Work |
| 2 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 3 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres. Extra for making of structural steel work required to be re-erected. |
| 4 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. |
| 5 | Dismantling roofing including ridges, hips, valleys and rafters etc. and stacking the within 50 meter lead of: Asbestos Sheet. |
| 6 | Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 7 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 8 | Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per MoRTH Specification Clause 301.3 up to lead 20 km. |
| 9 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 10 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 11 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix |
| 12 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1743) Hot rolled deformed bars (IS : 1139). |
| 13 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). |
| 14 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 15 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) |
| 16 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 17 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. |
| 18 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.42 kg/10 sqm). |
| 19 | White washing with lime to give an even shade including all scaffolding: New work (three or more coats). |
| 20 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 21 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 22 | Repair of rolling shutter with replacement of shutter spring incl. removal of old spring in the existing rolling shutter incld. Cost of new spring |
| 23 | Applying priming coat :With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 25 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 26 | Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size. Expended metal size 20-25 mm size 18SWG |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 28 | Electrification |
| 29 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm. nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS : 694) of approved make on surface ISI marked(IS-19427-P-II) PVCcasing capping and its accessories, round tiles, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point 6 A switch, 3.0 mm. thick ISI marked phenolic laminated sheet, zinc plated/brass screw, cup washers, making connections, testing etc. as required. Short point (upto 3mtr.) Group-2 |
| 30 | (a) Short Point (upto 3 mtr.) |
| 31 | (b) Medium Point (upto 6 mtr.) |
| 32 | (c) Long Point (upto 10 mtr.) |
| 33 | Wiring for 3 pin 5 amp light plug point with 1.5 sqmm. nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 Sq. mm. nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS:694) of approved make in surface/recessed ISI marked medium duty PVC conduit and it's accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in swith board & falce ceiling point, 6 A swith, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc. as required on board. Grade-II. |
| 34 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004) with heavy duty pole clamp, Saddles suitable fastners etc. As required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure 40 mm Dia. |
| 35 | S&Ffollowingsizes(dia.)ofISImarkedmediumdutyPVCconduitalongwithaccessoriesinsurface/recessedusingsaddles,clamps,fastenerasrequiredincludingcuttingthewall,coveringconduitand making good the same as required. 25mm |
| 36 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. Group p-2 |
| 37 | 1 x 1.5 sq.mm |
| 38 | 2 x 2.5 sq.mm |
| 39 | 2 x 4.0 sq.mm for powder circuit |
| 40 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 16.0 Sq. mm 4 Core. |
| 41 | P&F two pin energy efficient compact flourscent lamp in existing holder/fixture as required. 36 watt 4 pin Group-II |
| 42 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C/D tripping characterstic) ISI marked IS 8828 (1996)/ conforming to IEC 60898 in existing boards/sheets including making connections with lugs, testing etc. as required 6 A to 32 A rating (Havells, HPL, SSK, Anchor, Khaitan).Grade-II. |
| 43 | P&F 240/415 V isolator conforming to IS:13947-III/IEC 60947-3 on existing board/sheet including making connections with lugs, testing etc. as required 63 A rating (Havells, HPL, SSK, Anchor, Khaitan) Grade-II. |
| 44 | P&F Recessed/Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ power painted complete with 100 A copper bus bar, shorting link, neutral link, earth link and din bar, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs, testing etc. as required Single door (single phase) 12 Way. Grade-II. |
| 45 | Providing and fixing of non modular power plug point accessories as per PWD specification for electrical Works with 18 SWG G I box of size 175 x 100 x 60 mm with earthing terminal/connector on recessed/surface with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet [ as per detailed in respective item in BSR], making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 46 | Providing & Fixing of ISI marked (IS:2268-1994) ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\"attached with this BSR . |
| 47 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V- 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to< 5 ) |
| 48 | Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/Extruded Al Base Housing & diffuser SMD Mid Power LED tube (withintegral driver), on existing fixture. Power Consumption of 18W / 20Wsystem lumen efficacy ≥ 110 lm/Watt output, internal surge protection of2.5 KV ,THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 35000Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR. 4', 18/ 20 Watt LED Tube Without Batten (Extruded Al Base) |
| 49 | Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaireon existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum70% lumen maintened ,color Rendering Index >70 and CCT 5700K+355K. Surge protection shall be min ≥ 4 KV internal and min 10 KVexternal. driver should be Phase to phase protection of 440 V for 4Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . LED Street Light fixture 30 Watt |
| 50 | Less :- Credit for dismantled item in Pali (Old Steel @ 25/Kg @ *500 = 5000.00) = 12500.00 |
| 51 | Note :- (1) The quantity of dismantled material are tentative which my vary depending upon actual weightment/counting/measurement respectively. |
| 52 | H- SCHEDULE |
| 53 | Removing and refixing of existing Rolling Shutter of godowns by welding drilling complete including. Cost of welding rods and hire charge of welding machine and T&P etc complete as per direction of Engineer Incharge. |
| 54 | Removing and Refixing of GI sheet including cutting jhiri and repair, cutting of sheet, removing & refixing of Turbo ventilators, fixing of sheets by self drilling screws etc. complete as per direction of Engineer Incharge. Please Enable Macros to View BoQ information |