| 1 | HT. ALLUMINIUM CABLE: Supply erection testing of standard make XLPE 3 core HT / 11 KV grade ISI marked Stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of PVC, galvanised steel flat strip armoured, and overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with up to date amendments for making following connection a) from G.O switch to metering equipment . b) from metering equipment to transformer complete in all respect. Make: Indian Cables Ltd./ Polycab / RR Cables / CAPP / Finolex / Havells / Gloster / Universal / Fort Gloster Industries Ltd./ Indian Cable Co. / Asian Cables Corporation Ltd35 Sqmm size |
| 2 | LT CABLE ALLUMINIUM: Supply, erection, testing and commissioning of IS marked 3.5 core Cables, Solid Aluminum conductor up to 10sqmm and balance stranded conductor, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Aluminium wire for single core up to 70sqmm and balance Aluminium strip, Glavanised wire for cables up to2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip) extruded PVC type ST2 Outer sheathed, 650/1100V grade as per IS7098 (Part-1) 1988 with up to date amendments along with all accessories complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd. 240 Sqmm size |
| 3 | H.T. METERING PANEL: Supply, erection, testing and commissioning of 11KV Indoor H.T Metering Panel complete with suitable CTs, PTs and 3 phase, 4 wire Digital Electronic KWH Meter with accuracy class of 0.5 as per requirement and approval of DHBVN, consisting of the Cubical Panel Box of minimum size 700mm x700mm x1500mm free standing, floor mounting type made out of 14 SWG CRCA sheet steel powder coated with epoxy coated channel iron base frame. |
| 4 | Providing and fixing in position UPVC SWR Door Foot Bend (110M X 110M) as per SI 13592 of E.D.C Manufacture or of any other reputed firm complete in all respect. (Analysis Attached) |
| 5 | Providing and fixing in position UPVC SWR Reducer (110M X 90M) as per SI Manufacture of reputed firm complete in all respect. (Analysis Attached) |
| 6 | Providing and fixing in position UPVC SWR Bend (110M X 110M) as per SI Manufacture of reputed firm complete in all respect. (Analysis Attached) |
| 7 | SEWERAGE TREATMENT PLANT-BHAINSWAL.a) Design, construction, erection, testing and commissioning of 2.00 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including Landscaping, MCC Panel Room, all other contingent ie. Electrical, Mechanical, Piping and Instrumentation work with PLC and SCADA arrangement for STP integrated with MPS including furniture and laboratory equipments as per detail given in the bid document and following components.b) Supply and installation 2 Nos. fine Screens of suitable size for 2.00 MLD average flow with peak factor of 3.c) 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED suitable size, outdoor type energy efficient lamps on each pole, 20 no. LED outdoor light with 7 m. high GI pole along road / path including all accessories complete in all respect.d) Supply and installation of 1 No. 3.65 m wide Main Gate of MS and 1.25 m. wide wicket gate at STP to the entire satisfaction of Engineer-in-charge. (Total weight not less than 500 kg).e) Providing and installing 2 No. centrifuges (1Working plus 1 Stand bye) including centrifuge feed pump, all fittings, instrumentations, electric panel board etc. as per design complete in all respect including packing dry sludge in 20 Kg. bag and supplying the same in market Kisan Sewa Kendra or as directed by Engineer-in-charge within the lead as pointed at clause 4.4.4 of the DNIT. |
| 8 | ONLINE OUTLET EFFLUENT WATER QUALITY MONITORING SYSTEM-2...Supply, Installation, Testing, Commissioning, Operation and Comprehensive Annual Maintenance of effluent quality monitoring system at 2.00 MLD capacity STP at Bhainswal for online (continuous) measurement of PH, Total Suspended Solids (TSS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, HSPCB and PHED, TUV approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents and as contained in scope of work in the DNIT.a) Multi-parameter measuring converter, for connecting up to 18 intelligent sensors Scope including 8 analog inputs / outputs (4 inputs and 4 outputs) (0/4-20Ma), wide- range power supply Optical COD/BOD and TSS probe with spectral processing of the UV-VIS range, for measurement in the outlet / effluent of 2.00 MLD capacity STP at village Bhainswal with integrated with automatic cleaning.b) Robust digital pH/ORP sensor for pH/ORP electrodes, with built-in pre-amplifier and temperature sensor with Automatic Temperature Compensation (ATC) Cable length 100 Meter (minimum).c) Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to the intelligent Sensor Net system. Cable length 100 meter (minimum)d) Data transfer to CPCB, HSPCB and PHED servers.e) Providing GSM 3G, 4G modem with mobile network connectivity. |
| 9 | CC TV CAMERAS-Providing and Installing 6 CCTV Cameras (4 Cameras for STP and 2 Cameras for MPS) complete as per satisfaction of the Engineer– in- Charge, within 96 hours of signing the Agreement along with 90 days recording (DVR), 32 inch LED Screen, 16 Channel DVR at STP Site and 8 Channel DVR at MPS Site with connectors, cables, poles and power supply with online real-time output facility. The cameras at both the sites i.e. MPS and STP shall be synchronized at STP site.a) i) At STP and MPS Site- 1 No. PTZ speed dome 360 degree 50X zoom camera, 3 No. 12 mm lens size, 1 Nos. 3.6mm lens size.b) Make: - CP Plus Internet Protocol minimum 5 MP WDR, Night vision color mode 2.4.2 12 mm very focal with extra IR. CCTV Cameras should be installed and commissioned before starting of the work |
| 10 | ANNEXE BUILDING-Construction of HT / LT Panel room, PLC room, Centrifuge house, blower room and Lab cum office building including doors, windows and fittings with toilet block including all Sanitary fittings etc. as per drawings approved by SE at MPS and STP and covered area built up with RCC framed structure and brick work finished with vitrified glazed tiles flooring, powder coated aluminum frame made with 10 guage sheet having size 100mm x 45mm for chowkhat, 75mm x 45mm for door frame and 45mm x 45mm for window frame with 5mm thick glass AIS/Saint Gobain/ Modi Float. |
| 11 | Full Bore Electromagnetic Flow meterType : Full bore, Lining : Rubber, Output: 4-20mA, RS485, Internal Mounting, Input 220V AC /24 V DC, Temperature upto 80 degree, Pressure upto 20 Kg/cm2,Electrode SS316.150 mm Nominal Diameter Flow meter Rs. 70700/-Telemetry System for Flow meter Rs. 28500/- Total Rs. 99200/- |
| 12 | Glycerin filled Pressure gauge0-10kg/cm2 |
| 13 | Providing 200 mm dia. S.W. or R.C.C. pipes in vertical drop arrangement including providing 150 mm dia S.W. and R.C.C. pipe fixed in B.B. masonry of manhole at the required level including providing 150 mm dia double tee, 150 mm dia right angled bend, encasing in B.B. masonry 1:4 proportion all around the pipe, double tee, bend upto the foundation of manhole, jointing, cutting, filleting including neat cement rendering, plugging the opening with jungle wood knob complete as directed by Engineer-in-charge (0.60 M depth) excluding cost of chamber.a) As above but for 200 mm dia pipes and depth 0.60 M |
| 14 | Providing 200 mm dia. S.W. or R.C.C. pipes in vertical drop arrangement including providing 150 mm dia S.W. and R.C.C. pipe fixed in B.B. masonry of manhole at the required level including providing 150 mm dia double tee, 150 mm dia right angled bend, encasing in B.B. masonry 1:4 proportion all around the pipe, double tee, bend upto the foundation of manhole, jointing, cutting, filleting including neat cement rendering, plugging the opening with jungle wood knob complete as directed by Engineer-in-charge (0.60 M depth) excluding cost of chamber.Extra for every 0.5 M depth beyond initial depth of 0.60 M. |
| 15 | Providing 250 mm dia. S.W. or R.C.C. pipes in vertical drop arrangement including providing 150 mm dia S.W. and R.C.C. pipe fixed in B.B. masonry of manhole at the required level including providing 150 mm dia double tee, 150 mm dia right angled bend, encasing in B.B. masonry 1:4 proportion all around the pipe, double tee, bend upto the foundation of manhole, jointing, cutting, filleting including neat cement rendering, plugging the opening with jungle wood knob complete as directed by Engineer-in-charge (0.60 M depth) excluding cost of chamber.As above but for 250 mm dia pipes and depth 0.60 M |
| 16 | Providing 250 mm dia. S.W. or R.C.C. pipes in vertical drop arrangement including providing 150 mm dia S.W. and R.C.C. pipe fixed in B.B. masonry of manhole at the required level including providing 150 mm dia double tee, 150 mm dia right angled bend, encasing in B.B. masonry 1:4 proportion all around the pipe, double tee, bend upto the foundation of manhole, jointing, cutting, filleting including neat cement rendering, plugging the opening with jungle wood knob complete as directed by Engineer-in-charge (0.60 M depth) excluding cost of chamber. Extra for every 0.5 M depth beyond initial depth of 0.60 M. |
| 17 | Providing 300 mm dia. S.W. or R.C.C. pipes in vertical drop arrangement including providing 150 mm dia S.W. and R.C.C. pipe fixed in B.B. masonry of manhole at the required level including providing 150 mm dia double tee, 150 mm dia right angled bend, encasing in B.B. masonry 1:4 proportion all around the pipe, double tee, bend upto the foundation of manhole, jointing, cutting, filleting including neat cement rendering, plugging the opening with jungle wood knob complete as directed by Engineer-in-charge (0.60 M depth) excluding cost of chamber. |
| 18 | Providing 300 mm dia. S.W. or R.C.C. pipes in vertical drop arrangement including providing 150 mm dia S.W. and R.C.C. pipe fixed in B.B. masonry of manhole at the required level including providing 150 mm dia double tee, 150 mm dia right angled bend, encasing in B.B. masonry 1:4 proportion all around the pipe, double tee, bend upto the foundation of manhole, jointing, cutting, filleting including neat cement rendering, plugging the opening with jungle wood knob complete as directed by Engineer-in-charge (0.60 M depth) excluding cost of chamber. Extra for every 0.5 M depth beyond initial depth of 0.60 M. |
| 19 | Removal of Existing Pumping Machinery Labour charges for removing, disassembling, assembling and re-erection of pumps submersible pump set Labour charges for removing of 800 LPM, Head 60 m and 15 HP |
| 20 | Removal of Existing Pumping Machinary Labour charges for removing, disassembling, assembling and re-erection of pumps Submersible pump set Labour charges for removing of 600 LPM, Head 70 m and 20 HP |
| 21 | SEWERAGE TREATMENT PLANT-FARIDPUR. a) Design, construction, erection, testing and commissioning of 4.00 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including Landscaping, MCC Panel Room, all other contingent ie. Electrical, Mechanical, Piping and Instrumentation work with PLC and SCADA arrangement for STP integrated with MPS including furniture and laboratory equipments as per detail given in the bid document and following components. b) Supply and installation 2 Nos. fine Screens of suitable size for 4.00 MLD average flow with peak factor of 3. c) 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED suitable size, outdoor type energy efficient lamps on each pole, 20 no. LED outdoor light with 7 m. high GI pole along road / path including all accessories complete in all respect. d) Supply and installation of 1 No. 3.65 m wide Main Gate of MS and 1.25 m. wide wicket gate at STP to the entire satisfaction of Engineer-in-charge. (Total weight not less than 500 kg). e) Providing and installing 2 No. centrifuges (1Working plus 1 Stand bye) including centrifuge feed pump, all fittings, instrumentations, electric panel board etc. as per design complete in all respect including packing dry sludge in 20 Kg. bag and supplying the same in market Kisan Sewa Kendra or as directed by Engineer-in-charge within the lead as pointed at clause 4.4.4 of the DNIT. |
| 22 | Removal of Existing Pumping Machinary Labour charges for removing, disassembling, assembling and re-erection of pumps Submersible pump set Labour charges for removing |
| 23 | Providing, lowering in trenches to correct gradient and allignments, jointing with tytone rubber joint and cutting of RCC S/S pipes having inside HDPE. lining ISI marekd as per ISI code IS:458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc.,cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and to ensure this, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer incharge including all cartage etc copmplete in all respects. 400 mm i/d RCC NP3 pipe with inside H.D.P.E. lining |
| 24 | Providing, lowering in trenches to correct gradient and allignments, jointing with tytone rubber joint and cutting of RCC S/S pipes having inside HDPE. lining ISI marekd as per ISI code IS:458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc.,cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and to ensure this, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer incharge including all cartage etc copmplete in all respects. 450 mm i/d RCC NP3 pipe with inside H.D.P.E. lining |
| 25 | Providing, lowering in trenches to correct gradient and allignments, jointing with tytone rubber joint and cutting of RCC S/S pipes having inside HDPE. lining ISI marked as per ISI code IS:458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc.,cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and to ensure this, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer incharge including all cartage etc complete in all respects 350mm i/d pipe with inside H.D.P.E. liningR.C.C. pipe with inside H.D.P.E. lining class- NP-3 |
| 26 | Deduct -Less Credit of existing 35 No.-Submersible Pumping sets,Panel board, cable and dozzers etc |
| 27 | Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being 300mm |
| 28 | -ONLINE OUTLET EFFLUENT WATER QUALITYMONITORING SYSTEM-.Supply, Installation, Testing, Commissioning, Operation andComprehensive Annual Maintenance of effluent qualitymonitoring system at 4.00 MLD capacity STP at Faridpur foronline (continuous) measurement of PH, Total SuspendedSolids (TSS), Chemical Oxygen Demand (COD), BiologicalOxygen Demand (BOD) by single analyzer with varioussensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis withautomatic cleaning of censor, signal cables and power cables,local data acquisition and display of data on continuous basisfor up linking the data to CPCB, HSPCB and PHED, TUVapproved complete in all respect as per Central PollutionControl Board (CPCB) guidelines for online continuousmonitoring system for effluents and as contained in scope ofwork in the DNIT.a) Multi-parameter measuring converter, for connecting up to18 intelligent sensors Scope including 8 analog inputs /outputs (4 inputs and 4 outputs) (0/4-20Ma), wide- rangepower supply Optical COD/BOD and TSS probe with spectralprocessing of the UV-VIS range, for measurement in theoutlet / effluent of 4.00 MLD capacity STP at village Faridpurwith integrated with automatic cleaning.b) Robust digital pH/ORP sensor for pH/ORP electrodes, withbuilt-in pre-amplifier and temperature sensor with AutomaticTemperature Compensation (ATC) Cable length 100 Meter(minimum).c) Sensor adapter cable for all intelligent sensors, with IP68water proof connection to the intelligent Sensor Net system.Cable length 100 meter (minimum)d) Data transfer to CPCB, HSPCB and PHED servers.e) Providing GSM 3G, 4G modem with mobile networkconnectivity |
| 29 | Operation and Maintenance cum defect Liability period for 6 Years after successful completion of 3 Months trial run period for the complete scope of work taken in the DNIT. |
| 30 | Civil Work |
| 31 | HSR Items Please Enable Macros to View BoQ information |