| 1 | Demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars etc., complete all as specified and directed. |
| 2 | M & L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 metre mean radius in CM 1: 4 complete all as specified and directed by Engineer-in charge. |
| 3 | M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 but except bricks (old serviceable bricks to be used) complete all as specified Note : The rate includes for cleaning of old bricks. |
| 4 | Taking down cement plaster on brick stone or concrete walls ceiling etc including racking out joints, hacking for key, scrubbing down with water etc as specified and directed |
| 5 | M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation filling in mass concrete complete all as specified. |
| 6 | M & L Cement Concrete type B1 , 1:2:4 mix (20mm graded crushed stone aggregate ) as in bedding , benching of manholes , copings, roof kerbs and surface channel etc. complete all as specified |
| 7 | M & L for rendering 15 mm thick on fair faces of brick works masonry or concrete surfaces in CM 1:4 finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 8 | M&L for Preparation of new plastered wall surfaces complete all as specified and applying the following: -(a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified.(b) Two coats of exterior acrylic emulsion by using airless spray/roller over and including a coat of acrylic emulsion external primer, complete all as specified. |
| 9 | M&L for Complete removal of existing treatment of any description on old wall surfaces of any description, preparation of surfaces by mechanized sander having suction vacuum bag using smart periodical methodology complete all as specified and applying the following: -(a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of exterior acrylic emulsion by using airless spray/roller over and including a coat of acrylic emulsion external primer, complete all as specified. |
| 10 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 12 | M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation of posts and struts complete all as specified. |
| 13 | Mild steel work angle iron fencing posts and flat iron including embedding in concrete and screwing etc posts and struts in fencing incl cutting tops to shape as directed bent to shape, drilling holes notching for wire etc flat iron fillets (fro securing wire mess etc) including all necessary drilling bolting or riveting etc of Fe 290 Gde E-185 complete all as specified. |
| 14 | Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed wire with 2mm dia barbs at 75mm spacing and straining and fixing to any type of stranded rails, straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed (each line wire to be measured) complete all as specified. |
| 15 | Two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel and iron surfaces of any description exceeding 10 cm in width or girth including preparation of surfaces complete all as specified |
| 16 | M & L Mild steel work such as grills/ gates, gratings ,etc with ends of bars shouldered and /or riveted , or forged into spikes and similar work con-forming Fe .290.Gde-E-165 |
| 17 | M&L cement concrete type C2, 1:3:6 50 mm thick (40mm graded stone aggregate) as in floors, paths, plinth protections etc.; laid in alternate panels, and finishing top surface even & smooth without using extra cement, complete all as specified |
| 18 | Demolition of cement concrete (re-inforced) of any description and in any position not otherwise specifically provided for all as specified. |
| 19 | Providing precast cement concrete type B1 1:2:4 (20 mm graded aggregate) as in manholes covers, Kitchen sink slab, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified |
| 20 | M&L for RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) for slabs supported on walls, shelves, beams and columns, lintels, fins, facia and Chajjas etc and the like, complete all as specified. |
| 21 | Formwork for rough finished surfaces to soffit of suspended slab such as roof slab, floor slab/chajjas/beams/colns/fins/facia and spiral stair case not exceeding 200mm tick complete all as specified. |
| 22 | Providing precast cement concrete type B-1 1:2:4 (20mm graded aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces Set in CM 1:4 complete all as specified and directed. |
| 23 | M & L TMT bars 8mm dia and over cut to length , bent to shape required ,including cranking ,bending spirally hooping for columns , hooping ends and binding with and including MS wire (annealed) not less than 0.90m dia or securing with clips complete all as specified and directed. |
| 24 | M&L Providing precast cement concrete louvers and jallies, type B0 (12.5mm graded aggregate) , 40mm thick (measured solid), including all mouldings etc set in cement mortar 1:4, and also including demolition of existing reed lathing/precast RCC jallies etc complete all as specified and directed. |
| 25 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,watering and removing surplus soil to a distance n. exc 50 m and making good surface in soft/loose soil complete all as specified and as directed. |
| 26 | Removal of excavated material to a distance not. exceeding 50m & depositing where directed at level not exceeding 1.5m above the starting point complete all as specified and as directed . |
| 27 | M&L for PCC (1:2:4) type B-2, using 40mm graded stone aggregate as in foundation filling & mass concrete complete all as specified and as directed. |
| 28 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 29 | M&L for 60 mm thick rubber moulded glossy finish precast concrete interlocking pavers/tiles with grey cement and no pigment, confirming to IS 15658-2006 M-35 Grade, of any size & shape as directed in floors over & including 25mm thick sand screed bedding/cushioning etc complete all as specified and directed |
| 30 | M & L for Roof Trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified and directed. |
| 31 | M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 including rolled mild steel as in joint channel, angle or tee sections fixed independently withouy connection plates etc., (cut to ordinary length ie within 20mm of tile length indicated of gde Fe 410-S complete all as specified and directed. |
| 32 | M & L for Mild steel screw bolts (machine made ) with hexagonal or square heads at one end and screwed the other or screwed both ends ,each screwed end to be fiitted with washer and one hexagonal or square nut length of bolt exc 5 cm but n exc 10cm long complete all as specified and directed. |
| 33 | M & L for 25mm thick sand filling under interlocking tiles including watering and consolidating complete all as specified and directed. Please Enable Macros to View BoQ information |