| 1 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 m depth for foundation etc. and getting out in soft/loose soil complete all as specified and as directed |
| 2 | M & L for PCC (1:5:10) type E-2, using 40mm graded stone aggregates as in foundation filling & mass concrete complete all as specified and as directed |
| 3 | M & L 75mm thick PCC (1:4:8) type D-2, using 40mm graded stone aggregate as in sub base for flooring complete all as specified and as directed |
| 4 | M & L Brick work built in CM 1:6 with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed |
| 5 | Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed |
| 6 | M&L for providing RCC M25 design mix as in footings , foundations beams , plinth beams etc complete all as specified and as directed |
| 7 | M&L for providing RCC M25 design mix as in columns , pillers , piers , posts and struts complete etc complete all as specified and as directed |
| 8 | M & L for providing RCC M 25 using 20 mm graded aggregate in for beams, cantilevers, bressummers, lintels complete all as specified and as directed |
| 9 | M & L for providing RCC M 25 using 20 mm graded aggregate in for slab supported on walls complete all as specified and as directed |
| 10 | M&L for form work to sides of foundation sides & sofits of foundation beams plinth beam etc and similar work verticle or batter for rough finished surface of concrete flats complete all as specified and as directed. |
| 11 | Use and waste Formwork to sides of pillars, posts, struts, piers,columns, and stanchionsfor fair finished surfaces of concrete , square complete all as specified and as directed |
| 12 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick flat fair finished surfaces of concrete complete all as specified and as directed |
| 13 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide complete all as specified and as directed |
| 14 | Formwork to sides and soffits of Roof beams,Gable beams & lintel beam rough finished surfaces of concrete complete all as specified and as directed |
| 15 | S&F Mild steel bars TMT 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to Fe - 410 - 0 or Fe - 310 - 0 complete all as specified and as directed |
| 16 | Same as item No. 15 above but 8 mm dia stirupps , spacers and binders complete all as specified and as directed |
| 17 | Rendering 15mm thick in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and as directed. |
| 18 | Rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smoothe without using extra cement & with using integral water proofing compound complete all as specified and as directed. |
| 19 | M&L for rendering 5 mm thick in cement mortar in (1:3) finishing the surfaces even and smooth on ceiling complete all as specified and as directed. |
| 20 | S&F Solid PVC Door Frame of Size 50 mm X 47 mm made out of 5 mm plain colour PVC Sheet reinforced with MS Square tube, suppling and fixing in opening as per specification & drawing and complete all as specified and as directed. |
| 21 | S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed. |
| 22 | S&F aluminium anodised 100 mm long butt hinges with galvanised mild steel screws complete all as specified and as directed. |
| 23 | S&F aluminum anodised tower bolts 150 mm long complete all as specified and as directed. |
| 24 | S&F aluminum anodised handles , cast type anodised 125mm long complete all as specified and as directed. |
| 25 | S7F 2nd class HW 35mm thick facotry made panelled shutters with lock rail and panel of 9 mm bwp commercial ply of 12 mm veneered particle board with commercial veneering on both faces . The size of rail and stylr as per IS-1003 (pt-I) klin seasoned and chemically pressure treated complete all as specified and as directed. . |
| 26 | S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt 300 mm complete all as specified and as directed. |
| 27 | S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm complete all as specified and as directed. |
| 28 | S & F 150 mm mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed. |
| 29 | Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed |
| 30 | S & F 4 mm thick figured glass, pin head type and glazing with oil putty in ventilator complete all as specified and as directed. |
| 31 | S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and avarage width of aparture 1.18 mm and fixed with tinned tacks ro galvanised wire stapple complete all as specified and as directed. |
| 32 | M & L hard core of gauge not exceeding 63 mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface with broken bricks bats complete all as specified and as directed. |
| 33 | M&L for 15 mm thick Screed bed or bedding layer in CM (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and as directed. Note : Using only course sand in screed bed. |
| 34 | M&L Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but n.exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 35 | M&L for 10 mm thick rendering in cement mortar 1:4 and finish the surface rough to receive the tile finish etc complete all as specified and as directed. Note :- Rendering will be done in course sand (Toka sand) only |
| 36 | S&F glazed ceramic coloured tiles 7mm thick 450 x 300mm size in verticle surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. etc complete all as specified and as directed. |
| 37 | S&F vitreous china squatting pan Orissa pattern of size 580mm x 440mm with integral foot rest and 'P' or 'S' trap including Cement concrete bedding , connecting flushing pipe and `P' trap, complete all as specified and as directed. |
| 38 | S & F 10 litre capacity PVC valve less syphonic action type flushing cistern low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. |
| 39 | S & F tubes medium grade galvanised with all fittings 15 mm bore and fixed complete to walls and ceiling or laid in floor etc. complete all as specified and as directed. |
| 40 | S & F tubes medium grade galvanised with all fittings 20 mm bore and fixed complete to walls and ceiling or laid in floor etc. complete all as specified and as directed. |
| 41 | S&F 500 litres capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. |
| 42 | S & F cast copper fancy type chromium plated alloy bib tap for 15 mm bore of pipe screwed down, screwed for iron pipe or for brass furrel and fixed complete all as specified and as directed. |
| 43 | S & F cast copper alloy chromium plated fancy type stop valves for 15 mm bore of pipe screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 44 | S & F cast copper alloy chromium plated fancy type stop valves (Concealed type) for 15 mm bore of pipe screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 45 | S & F Ball brass valves high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed for 20 mm dia bore of pipe complete all as specified and as directed. |
| 46 | S & F 100 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps / laid in trenches complete all as specified and as directed. |
| 47 | S & F 75 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps / laid in trenches complete all as specified and as directed. |
| 48 | S & F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified and as directed. |
| 49 | S & F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified and as directed. |
| 50 | S&F 75 mm dia CI floor trap with grating incluing jointing to waste pipe fixed in cement concrete (1:2:4) type B-1, complete all as specified and as directed. |
| 51 | S & F 100 mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed. |
| 52 | S&F 100 mm bore CI cowl complete all as specified and directed |
| 53 | S&F 75 mm bore CI cowl Complete all as specified and directed |
| 54 | M&L for in repair 100 mm dia of CI P trap long with grating incl jointing to waste pipe fixed in cement mortar 1:2:4 type B-1, complete all as specified and as directed. |
| 55 | S&F pressed steel frames of size 105x60 mm for doors with one or more rebates incl necessary fixing lugs , hinges , lock strike plate etc ( thickness of sheet shall be 1.25 mm) and making good the wall with plaster in CM 1:6 complete all as specified and as directed. |
| 56 | M&L PCC 1:3:6 type c-1 using 20mm graded stone aggreegates for filling in bed block of hold fast etc complete all as specified and as directed |
| 57 | S&F brass chromium plated shower rose 125 mm size with or without swivel joints fix to steel pipe or union complete all as specified and directed |
| 58 | PCC (1:3:6) type C-2 (using 40mm graded agg) 75mm thick as in plinth protection complete all as specified and as directed. |
| 59 | M & L preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed. |
| 60 | M & L preparation of newly plastered surfaces of wallsand applying three coat of white wash on walls complete all as specified and as directed. |
| 61 | M&L for prepairing new surfaces of ceiling and applying two coat of white wash etc complete all as specified and as directed. |
| 62 | M & L returning filling including spreading levelling watering and well ramming in layers n exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 63 | M & L removing excavated material exc 250n exc 500 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed. |
| 64 | Supply only liquid integral water proofing compound of approved quality and make confirming to IS. complete all as specified and as directed. |
| 65 | S & F vitreous china white wash hand basin white flat back size 450 x 300 mm excluding waste chain and plug on porcelain stopper butt including brackets complete all as specified and as directed. |
| 66 | S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including connections to flushing pipe and out going pipes etc complete all as specified and directed. |
| 67 | S & F pillar taps cast copper alloy chromium plated fancy type with Capstan Head CP fixed connects with 15mm dia bore of pipe complete all as specified and as directed. |
| 68 | S&F brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed. |
| 69 | S & F PVC connections 15 mm dia with PTMT Nuts of length for 600 mm Long complete all as specified and as directed. |
| 70 | S & F 600 x 450mm bevelled edge selected quality looking mirror complete all as specified and as directed. |
| 71 | M&L preparation of newly wooden surface of any description & applying two coats of synthetic enamel paints over ofpin primer includ preparation of surface complete all as specified and as directed. |
| 72 | M&L preparation of newly steel surface of any description & applying two coats of synthetic enamel paints over red oxideprimer includ preparation of surface complete all as specified and as directed. |
| 73 | S&F urinal spredaer of PTMT any colour for fixing with 15mm dia pipe (minimum weight 60 gms) complete all as specified and as directed. |
| 74 | Concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete type D-2 1:4:8 using 20 mm graded curshed stone aggregates for 150mm bore pipes complete all as specified and as directed. |
| 75 | Salt glazed stoneware (SGSW) grade `A' drain pipes 150mm bore laid and jointed on concrete bed, complete including testing etc all as specified and shown drawings (Concrete bed shall be assured and paid for separately) complete all as specified and as directed. |
| 76 | M & L for Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: - |
| 77 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and as directed. |
| 78 | One Socket outlet three pin, 6 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and as directed. |
| 79 | One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and as directed. |
| 80 | Note for serial item No 76 to 79:1. Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. 2. GI boxes shall be fixed flush in position with cement mortar (1:4) complete all as directed. |
| 81 | S&F Switch modular type single pole, one way, 6 Amp, one module, complete all as specified and as directed. |
| 82 | S&F Switch modular type single pole one way, 16 Amp, one module, complete all as specified and as directed. |
| 83 | S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6 Amp, two module, complete all as specified and as directed. |
| 84 | S&F Socket outlet modular type multipurpose 2/3 pin single pole one way 6/16 Amp, two module, complete all as specified and as directed. |
| 85 | S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed. |
| 86 | S&F sheet metal encloser double door 8 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 87 | S&F MCB 6-32 Amp SP 10 KA ‘B’ series complete all as specified and as directed. |
| 88 | S&F RCBO for EARTH LEAKAGE, Overload & Short circuit protection 230V 32A AC type 10kA Double pole 30mA ISI marked complete all as specified and as directed. |
| 89 | S&F wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 20watt, 1.2 m T5, 6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete all as specified and as directed. |
| 90 | S&F wall mounted LED batten fitting 1X10 watt, 6500K, 2 ft complete with decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviroment friendly, energy efficient complete with all light fittings connection complete all as specified and as directed. |
| 91 | S&F angle lamp holder polycarbonate type with back plate complete all as specified and as directed. |
| 92 | S&F LED 7W Lamp base B-22 complete all as specified and as directed. |
| 93 | S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete all as specified and directed |
| 94 | M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed |
| 95 | S&F Heavy duty plastic body ventilation fan of 250mm sweep ,240 volt, having RPM not less than 1200, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including grouting of bolts and making good to distubed wall complete all as specified and directed |
| 96 | S&F & testing for storage type water heater (Geyser) electrical operated 230/240 Volts 25 ltr capacity, BEE 5 star rated complete including manufactured recommended multipurpose valve, NRV, plugtop, flexible pipe of set of two, sheathed cable etc. & including electric/earth connections and carrying out grounting & complete installations with mounting bolts,nuts complete all as specified & directed |
| 97 | Supplying and fixing 1100volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10.0 sqmm including 01x house service brackets made up of 40mm dia medium grade GI pipe bent at 90° angle of length not more than 3.0m complete all as specified and as directed. |
| 98 | M & L for Cutting existing steel tubing 25/32 mm for alterations or additions (Each cut measured) including screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector complete all as specified and directed. |
| 99 | Design,Supply, installation, testing and commissioning of Double Skin Water Cooled Air Washer Unit minimum capacity of 10000 CFM having outside precoated sheet 0.63 mm and inner side sheet 0.63 mm plain GI , 23+2mm puff panel Draw through type Air Washer complete with Hollow Aluminium profile consisting of blower section with imported DIDW forward curved centrifugal blower, cellulose Pad 200 mm thick , pvc eliminator , SS 304 tank 1.2 mm mono block pump with EU-4 (The velocity across filter not to exceed 500 FPM) . Air Washer Unit shall be PUF injected (CFC Free) , AMCA approved forward curvedCentrifugal blowers , TEFC weather proof motor IP-55 Class F insulation, belt drive multi sheave pulley mounted on motor and fan shaft , belt guard, motor & fan mounted on comman base frame vibration isolator , fire retardant double canvass connection (fungal resistant and lint free), internal lights, limit switches, canvas connection , viewing glass doors necessary instruments Area .Internal electrical connection upto starter complete with suitable size of copper wiring complete . MS stand for air washer unit of MS angle 50x50x5mm angle with support angle 06 nos, vibration insulation pads 06 nos, complete with coats of epoxy primer and 2 coat of black paint complete all as specified and directed.Minimum specification are as under:- Make:- Humidin/Zeco/Edgetech Air Flow Capacity:- 10000 CFMSize of blower- 560mm dia Motor Capacity:- 5.0HP 3PH, 1440 RPM ( ABB/Crompton Greaves/havells)Thick of cellulose pads - 200mm ThickWater Pump -0.5 HP, 230 Volts -02 Nos ( 01No for Standby)PUF material density:- 40 Kg/CumThickness of insulated panels:- 25 mm thick panel , PUF injected |
| 100 | The Air Washer Unit shall be specification as per below:-Housing/CasingThe housing/casing of the cooling unit shall be of double skin construction. The frame work shall be of extruded aluminum hollow sections. All the frames shall be assembled using, pressure die cast aluminum joints to make a sturdy strong & self supporting frame work for various sections. 25mm thick double skin panels shall be made of 0.63mm pre-plasticized / pre-coated plasticized sheets GSS on outside and 0.63mm Galvanized sheet inside with CFC-free PUF,38 kg per Cu M density insulation injected in between. These panel shall be fitted on to the frame-work with soft rubber gaskets fixed in built-in grooves of Aluminum frame in between to make the joints airtight.The entire housing shall be mounted on extruded aluminum channel frame work having pressure die cast aluminum jointers. Tank:- Tank shall be constructed of 18 G Stainless Steel 304 Grade with necessary slope on both sides to facilitate fast removal of drain water. The tank shall extend over the cellulose pads. This tank shall be of sufficient cross sectional dimensions to hold a large quantity of water. The design shall allow sufficient and easy access for cleaning the tray. The tank shall be provided with suitable connections to connect Inlet pipe line coming from Water tank.Make up water arrangement provided shall be complete with a brass ball float valve to maintain the water level in the tank. |
| 101 | Motor and Drive:-Fan motors shall be 415 ± 10% volts 50 cycles 3 phase squirrel cage, totally enclosed fan cooled with IP-55 protection. Motor shall be specially designed for quite operation and motor speed shall not exceed 1440 RPM. Drive to fan shall be provided through belt drive arrangement. Belts shall be of oil-resistant type. Adjustable sheaves shall be provided. Blower fan :- The fan shall be forward, curved double inlet double width type complete with motor and drive package. The wheel and housing shall be fabricated from heavy gauge galvanized steel. The fan impeller shall be mounted on a solid shaft supported to housing with angle iron frame and pillow block heavy duty ball bearings. The impeller and fan shaft shall be statically and dynamically balanced. The fan outlet velocity shall not be more than 12 M/Sec. The fan housing with motor shall be mounted on a channel base mounted inside the housing on anti vibration springs mounts. The fan outlet shall be connected with casing through fire retardant canvass. Wet Deck Humidifiers: Wet deck humidifiers pads shall be cellulose pad minimum 200mm thick to provide at least 90% saturation efficiency at 2.5 M/sec or less air face velocity. The Cellulose paper pads shall be housed in a galvanized steel casing complete with water distribution header and interconnecting heavy duty G I or PVC pipes between pump and distribution header. The media shall be of 100% imported origin of Munters/Glacier make. |
| 102 | Supply and installation of GI, Pre fabricated rectangular GI ducts, of 24 SWG, Glavanised Iron Sheet thickness 0.70 mm complete with MS flanges and bracing (as specified), necessary supports using thread rods (as directed) and anchor bolts, supply air collars, vanes, splitters,any retrofit work complete with for suitable air flow incl cutting on wall and make a good to disturbed area as per existing complete all as specified and directed. |
| 103 | Supply and installation of GI, Pre fabricated rectangular GI ducts, of 22 SWG, Glavanised Iron Sheet thickness 0.70 mm complete with MS flanges and bracing (as specified), necessary supports using thread rods (as directed) and anchor bolts, supply air collars, vanes, splitters,any retrofit work complete with for suitable air flow incl cutting on wall and make a good to disturbed area as per existing complete all as specified and directed. |
| 104 | Supply, installation, Exhaust air rectangular Grill of size 275X 550mm \\" with powder coating with Damper including civil work with core cut, chieseiling , cutting of wall , plaster etc and making good disturbed surfaces area after fitting the all respect complete all as specified and directed. |
| 105 | supply and, Installation , testing and commisioning of control panel with star delta starter and one DOL starter for water pump & three pahse indicator , Amp meter , voltmeter,overload protection relay, single phase preventor & MCCB 100 A 25 KA complete all as specified & directed. |
| 106 | Supply , installation , testing and commissioning of Pramount/Nitrile rubber close cell flat insulation 06 mm thick on SA Duct ony required sun expose area apllied on Newly installed Ducting line complete all as specified and directed. |
| 107 | Supplying, Laying ,and testing in of XLPE insulated armoured heavy duty electric cable of the size 25 Sqmm 4 core following size ,1100 Volts grade , with stranded aluminium conductor served with aninner sheathing of PVC tape armoured with GI wire and over all PVC sheathed in laid trenches/ passing through pipe/duct/road crossing/surface of wall/in hume pipe etc including fixing hardware,clamps,gland, thimble and making good the damaged surfaces etc complete all as specified and as directed. |
| 108 | Material and labour sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to matched and finised with existing surface are included in the rate complete all as specified and directed.Note:- (i) 4 run of 6.0 Sqmm main cable, one run of 6.0 Sqmm earth wire and two run length of PVC conduit of size 32mm shall be considered as one running length.(ii) The wiring shall be done in proper color coding using Red,Yellow, Blue for phases, Black for neutral and Green for earth. |
| 109 | M&L labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed. |
| 110 | Supply and fixing of 3 layer PVC water Tank capacity of 1000 Ltr incl ball brass valve high pressure ,with polythene float and flynut complete fiitting on existing roof complete all as specified and directed. |
| 111 | Supply & laying on wall /floor/ ceiling Galvanized water Tubing 25 mm medium grade with all fitting complete all as specified and as directed |
| 112 | Supply & laying on wall /floor/ ceiling Galvanized water Tubing 15 mm medium grade with all fitting complete all as specified and as directed |
| 113 | M&L , Gun metal globe valve 25 mm with iron wheel head heavy duty screwed both ends for iron pipe for union , ISI marked complete all as specified & directed |
| 114 | M&L , Gun metal globe valve 15 mm with iron wheel head heavy duty screwed both ends for iron pipe for union , ISI marked complete all as specified & directed |
| 115 | Note:- 1. All civil work as per site requirement for installation of Air washer Unit and fixing/hanging of Air Duct will be included in the overall rate quoted by the firm.2. Work of Air washer Unit will be executed through specialized agency having minimum 03 year experience in this field.3. The access door of air washer unit shall be equipped with a micro switch interlocked with the motor to ensure switching off of the motor automatically in the event of door opening. Please Enable Macros to View BoQ information |