| 1 | Excavation in trenches n.exc 1.5m wide and n.exc1.5 m in depth for foundation, or shafts, wells, cess pits manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil / rock (soft / hard / dense soil /rock) complete all as specified and directed. |
| 2 | Excavation in trenches n.exc 1.5m wide and n.exc1.5 m in depth for foundation, or shafts, wells, cess pits manholes, pier holes etc n.exc 10 Sqm on plan and exc 1.5 m in depth and n exc 3.00 m depth and getting out in any type of soil / rock (soft / hard / dense soil /rock) complete all as specified and directed. |
| 3 | M & L for Returning & filling in including spreading, levelling, watering & well ramming in layers n.exc 25mm thick in soft/ hard / dense soil complete all as specified and directed. |
| 4 | Removing surplus excavated material out side MOD land complete all as specified and directed. |
| 5 | M&L for PCC 1:4:8 type D-2 using (using 40 mm graded stone aggregate) as in foundation filling and mass concrete base commplete all as speified and directed. |
| 6 | Demolition & breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar, internal dia / bore of pipe 150 mm. including removing debries out site MOD land complete all as specified and directed. NOTE:- Excavation / earth work shall be measured and paid seperately. |
| 7 | Demolition & breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar, internal dia / bore of pipe 200 mm. including removing debries out site MOD land complete all as specified and directed. NOTE:- Excavation / earth work shall be measured and paid seperately. |
| 8 | Demolition & breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar, internal dia / bore of pipe 300 mm. including removing debries out site MOD land complete all as specified and directed. NOTE:- Excavation / earth work shall be measured and paid seperately. |
| 9 | S&F 150 mm bore (inner dia) double wall corrugated HDPE pipes (SN8) in any length including all fittings and jointing with elastomeric rubber rings and couplers / other jointing materials as per manufacturers instructins, laid over and including 150 mm thick sand coushning in trenches or in floors all as specified and directed. |
| 10 | S&F 200 mm bore (inner dia) double wall corrugated HDPE pipes (SN8) in any length including all fittings and jointing with elastomeric rubber rings and couplers / other jointing materials as per manufacturers instructins, laid over and including 150 mm thick sand coushning in trenches or in floors all as specified and directed. |
| 11 | S&F 300 mm bore (inner dia) double wall corrugated HDPE pipes (SN8) in any length including all fittings and jointing with elastomeric rubber rings and couplers / other jointing materials as per manufacturers instructins, laid over and including 150 mm thick sand coushning in trenches or in floors all as specified and directed. |
| 12 | S & F for 300mm dia reinforced concrete pipes class NP-2 laid and jointed with CM (1:1) complete with collars all as specified and directed. |
| 13 | M & L for concrete bed PCC 1:4:8 Type D2 (Using 40mm graded aggregate) to drain pipes 150 mm dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified and as directed. |
| 14 | M & L for concrete bed PCC 1:4:8 Type D2 (Using 40mm graded aggregate) to drain pipes 200 mm dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified and as directed. |
| 15 | M & L for concrete bed PCC 1:4:8 Type D2 (Using 40mm graded aggregate) to drain pipes 300 mm dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified and as directed. |
| 16 | Demolition of brick work built in cement mortar including all quains, arches, pillers etc and removing debries out site MOD land complete all as speified and directed. |
| 17 | M&L for brick work with sub class B bricks of old size built in cement mortar 1:4 straight or curved on plan exceeding 6m mean radius all as specified and directed. |
| 18 | M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 19 | M/L for concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping, bed plates and the like including necessary formwork and finishing the surface fair and even without using extra cement complete all as specified and directed. |
| 20 | Taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. raking out joints ,hacking for key and scrubbing down with water upto 4 storeys building, complete all as specified and directed. |
| 21 | M&L for 10 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for 15 mm thick cement plaster in cement mortar 1:6 on brick surfaces on fair face of brick work and finished even and smooth without using extra cement complete all as specified and directed. |
| 23 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed. |
| 24 | S&F in repair factory made SFRC manhole/drain cover (Grade M-25) heavy duty cover slab in rectangular / circular/ squared shaped of any size as required any thicknes incl MS sheet 2 mm thick all around the cover, set in cement mortar (1:4) , complete spefcified and directed. |
| 25 | Cleaning of all blockage of water closet ,gully/Nahani traps ,floor traps , compltete soil,waste and vent pipes etc in any situation getting out sludge or any other materials and make complete line functional incluing cleaning filling complete all as specified and directed. |
| 26 | Cleaning and removal of under ground blocked sewer line at any depth, any type and size upto any dia bore of sewer line in between manholes and making the line in working condition by Mechanically used water fitting Hydraulic pressure sewer sucker machine/ capacity min 5000lit , removing all sludge and solid, semi-solid, sludge and water or any shape from sewer line and manholes by blocking the line from one manhole to other manholes and cleaning the line by flushing with water includind loading and removing the taken out sludge/organic material in covered transort and disposing the same out side MOD land complete all as specified and directed Note - After receiving complaint from MES Rep by Contractor's supervisor / Site Engineer, job to completed within 12 working hours. (Rate include all mobilisation of machine ,labour, Operator, helper reqd to clean the machine, T &P and other minor charges for 08 working Hrs). |
| 27 | Cleaning of under ground sewer line at any depth, any type and size upto 200mm bore of sewer line in between manholes and making the line in working condition by Mechanically used water fitting Hydraulic pressure machine means removing all sludge and solid, semi-solid or sludge or any shape from sewer line and manholes by blocking the line from one manhole to other manholes and cleaning the line by flushing with water includind loading and removing the taken out sludge/organic material in covered transort and disposing the same out side MOD land complete all as specified and directed Note - After reciving complaint from MES Rep by Contractor's supervisor / Site Engineer, job to completed within 12 working hours. |
| 28 | Cleaning of under ground sewer line at any depth, any type and size exceeding 200mm and not exceeding 300mm bore of sewer line in between manholes and making the line in working condition by Mechanically used water fitting Hydraulic pressure machine means removing all sludge and solid, semi-solid or sludge or any shape from sewer line and manholes by blocking the line from one manhole to other manholes and cleaning the line by flushing with water includind loading and removing the taken out sludge/organic material in covered transort and disposing the same out side MOD land complete all as specified and directed Note - After reciving complaint from MES Rep by Contractor's supervisor / Site Engineer, job to completed within 12 working hours. |
| 29 | Dismantling to Stone slabs and tiles of any description or thickness in floors, aprons etc, and inclu removal upto 20 km from premises (defence land), complete all as specified and directed. |
| 30 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness ( below or above GL ) including removing debries out site MOD land complete all as specified and directed. |
| 31 | M&L for 75 mm thick PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) as in plinth protection, path/hardstanding/subbase etc complete all as specified and directed. |
| 32 | M&L 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded aggregate) as in sub base all complete and all as specified . |
| 33 | M&L for rubber moulded glossy finished colour Chequered cement concrete tiles with white cement and pigment 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry incl 15mm thick Screed bed or bedding layer of cement mortar 1:4 for for laying tiles including demolation all as specified and directed. |
| 34 | M & L for Machine pressed precast conctete colour interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment laid and bedded on sand cushioning complete all as specified and directed. |
| 35 | M & L for Machine pressed precast conctete colour interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade with grey cement and pigment laid and bedded on sand cushioning complete all as specified and directed. |
| 36 | M&L for Sand filling under floors or in foundations including watering and consolidation all as specified and directed. |
| 37 | M&L in repair factory made precast PCC kerb stone of size 30cmx15cmx30cm or 30cmx15cmx45cm manufactured by M-30 grade of concrete fixed in jointed with cement mortar (1:4) including necessary excavation ,returning filling, 2coats of exterior emultion over a coat of primers of existing kerb stone complete all as specified and directed. |
| 38 | M&L pure black Granite (of any type) tiles 20mm (+-2mm) thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including moulded of edges grinding and polishing complete all as specified and directed. |
| 39 | S&F in repair SFRC manhole cover(Grade M-25)of size 600mm dia x 70mm thick with MS Cover 2 mm thick alround including frame set in cement mortar 1:4 complete all as specified and as directed. |
| 40 | Taking up or down CI/PVC pipes (incl all fittings), with spigot and socket ends and lead joints incl burning out joints and removing lead of 100/75mm dia pipe complete all as specified and directed. |
| 41 | S&F PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc complete all as specified and directed. |
| 42 | S&F PVC SWR bends 110 mm dia complete all as specified and directed. |
| 43 | S&F 110 mm PVC SWR Junction single (Single T) provided with access door complete all as specified and directed. |
| 44 | S&F PVC (SWR) pipes 75 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc complete all as specified and directed. |
| 45 | S&F PVC SWR bends 75 mm dia complete all as specified and directed. |
| 46 | S&F 75 mm PVC SWR Junction single (Single T) provided with access door. |
| 47 | S&F in repair PVC (SWR) floor trap, size 75mm, plain with grating including jointing with solvent cement, complete all as specified and directed. |
| 48 | S&F UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed. |
| 49 | Cleaning of all blockage of Covered drain at any situation getting out sludge or any other materials (debries/ brocked drain cover/ vegitation / soil,) and make complete line functional incluing cleaning of drains of any size / depth and removing sludge /organic material in covered transport and disposing the same out side MOD land complete all as specified as and directed by Engr-in-charge.Note : Rate including removing cover of drains and refixing also. |
| 50 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 51 | S&F mild steel framed work such as grills,manhole cover,Drain cover, gratings, with ends of bars shouldered and/or riveted, or forged into spikes : framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 as complete all as specified and directed. |
| 52 | S&F mild steel, 1.50mm thick plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 53 | M&L Preparation of new or old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed complete all as specified and directed. |
| 54 | Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc. of capacity exc 250 ltr and n. exc. 500 ltr, incl write a letter to date of tank cleanining, complete all as specified and directed. |
| 55 | Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc. of capacity exc 500 ltr and n. exc. 1000 ltr, incl write a letter to date of tank cleanining, complete all as specified and directed. |
| 56 | Demolition of wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/ slabs/ blankets/board fixed in aluminum door or partition, any thickness, including cover fillets & framed work if necessary complete all as specified and directed. |
| 57 | S&F (3-4) mm thick ACP wall cladding sheet in colour as directed by Engr-in-charge fixed on MS frame . The size of each panel not exc 1.5sqm. MS frame to be fixed on walls, chajja,gate and fasad. including necessary repairing work as reqd, including weather sealing sealant, masking tape, including cutting of V groves to fixing moulded ACP sheet self-tapping screw complete all as specified and directed.Note:- .Work to be carried out upto four storey bldg with MS scaffolding not bamboo. |
| 58 | S&F in repairs for PVC tank cover for suitable for existing rotational moulded polyethylene water storage tanks capacity exc. 500 ltrs and n.exc. 1000 ltrs (cylindrical vertical with closed top) complete all as directed. |
| 59 | M&L for preparation on new or previously untreated wall and applying Two or more coats of 100% Premium acrylic emulsion paint having and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) over and including priming coat of exterior primer sqm over new surfaces over k wall care putty up to four stories bldgs complete all as specified and directed. |
| 60 | Material & Labour for prepration of old plastered or unplastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less applying Two or more coats of 100% Premium acrylic emulsion paint having and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) over and including priming coat of exterior primer sqm over new surfaces over wall care putty up to four stories bldgs complete all as specified and directed. |
| 61 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 62 | M&L cement concrete 1:3:6 type C-2 (40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 63 | S &F M S Work in post and struts in fencing inc cutting top to shape ,drilling holes,notching for wire etc,flat iron fillets inc all necessary drilling,bolting or rivetting and similar work cofirming to Fe -290 Gde E-165 complete all as specified and directed. |
| 64 | Supply only Chain link MS galvanised fencing, any size or type weighting complete all as specified and directed. |
| 65 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 66 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long dia of shank 5 to 10 mm complete all as specified and directed. |
| 67 | S&F for mild steel round bars, 10 mm dia and over cut to length bent to shape required including cranking binding spirally, hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality conforming to Fe-410W Gde E-250 complete all as specified and directed. |
| 68 | Supply , laying and fixing in repair of galvanized punched tape concertina coil , complete having galvanized spring steel core wire 2.5mm dia cold drawn steel, galvanized punched of low carbon steel having series of sharp barbs uniformly punched along its length 550 nos, barbs on periphery per revolution,crimped on steel spring core wire complete all as specified and directed. |
| 69 | S&F in repair painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws all as specification complete all as specified and directed. |
| 70 | M & L in repair 35mm thick louvers and jalli precast cement concrete 1:2:4 type B0 (using 12.50 mm graded stone aggregate) set in cement mortar (1:4) (measured solid), including all moldings , complete all as specified and directed. |
| 71 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut to facilitate demolition) all as specified and directed. |
| 72 | M & L reinforced cement concrete (nominal mix) 1:2:4 Type B1 (using 20 mm graded stone aggregate) as in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like all as specification complete all as specified and directed. |
| 73 | M&L for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. |
| 74 | M&L for form work to sofits of suspended slab such as roof slab, floor slab, landing and similar work not exc 200mm thick. Rough finished surfaces complete all as specified and directed. |
| 75 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 76 | M&L non skid ceramic coloured printed tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or bedding layer in cm (1:4) complete all as specified and directed. |
| 77 | M&L Glazed coloured ceramic tiles in vertical surface 450mm X 300mmX 7mm/300mmx200mmx7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 78 | S&F in repair vitreous china squatting pan “orrisa” pattern of size 580mmx440mm “white” with integral foot rest (excluding flushing cistern and flush pipe) incl provision of cement concrete bedding, ‘P’ trap 100mm dia connection to trap , anti-syphonage complete all as specified and directed. |
| 79 | S&F in repairs viterious china wash down water closet pan (Pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe) incl P or S trap etc complete all as specified and directed. |
| 80 | S&F in repair PVC flushing cistern of 10 ltr capacity valveless, symphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including flush pipe of 32mm bore PVC and connection to pipes etc and taking down existing flushing cistern complete all as specified and as directed. |
| 81 | S&F of plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 82 | S&F in repairs vitreous china wash hand basin of size 550mm x 400mm white, flat back including angle iron brackets with two coats of synthetic enamel paints including PVC waste pipe of 32mm dia of suitable length, PVC connection of 15mm dia & 450mm long with PTMT nuts, and 32mm dia brass waste fitting complete all as specified and directed. Please Enable Macros to View BoQ information |