| 1 | Labour only for removing blockage of WC (Indian or EWC), urinal, bath and kitchen, gully trap including cleaning of pan, floor trap and removing blockage of down pipe upto first manhole complete all as specified and as directed. Notes. (i) The item shall be operated on demand/complaint of users and shall be executed on specific written directions of Engineer-in-charge/JE.(ii) All written dockets shall be serially numbered, jointly signed including user with Bldg/Qtr No and entered in MB for the purpose of measurments and payment. (iii) A recovery of Rs. 200/- for each complaint shall be deducted from the payment due to the contractor in case the complaint is not attended and blockage is not removed within 24 hours. Decision of GE shall be final and binding in this regard. Documents in support of satisfactory completion of each complaint shall be preserved by contractor and submitted for verification. |
| 2 | Cleaning of existing SGSW/RCC pipe line of 100mm and 150mm dia pipes between manholes by mechanical operated machine for removing the blockage, debries from pipes, taking out the blocked sludge debries etc collected in the manholes from pipe, cleaning and depositing sludge/debries to excavated pit/area, spreading necessary insecticise where sludge is deposited and covered with soil all as specified and as directed. (all sludges/debries should be deposited in nearest pit & covered with soil & necessary disinfection be carried out)Note:- A recovery of Rs. 200/- for each complaint shall be deducted from the payment due to the contractor in case the complaint is not attended and line is not cleaned within 24 hours. Decision of GE shall be final and binding in this regard. |
| 3 | All as per serial item No 2 above but for 200mm to 250mm bore pipes. |
| 4 | All as per serial item No 2 above but for 300mm to 450mm bore pipes. |
| 5 | Dewatering and removing the sludge from 25 to 50 users septic tank in covered vehicle and cleaning the septic tank with water and removing the sludge outside th MD land, depositing and carrying out necessary disinfection where sludge is deposited complete all as specified and as directed by Engineer-in-charge. |
| 6 | All as per serial item No 5 above but for septic tanks of capacity 100 to 150 users. |
| 7 | All as per serial item No 5 above but for septic tanks of capacity 200 to 500 users. |
| 8 | Dewatering of sokage well of 25 to 50 users in covered vehicle and removing the sludge outside the MD land & depositing and carrying out necessary disinfection where sludge is deposited all as specified and as directed. |
| 9 | Excavation in trenches, not exc 1.50m wide and not exc 1.50m in depth; for foundations, etc. or for manholes etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in any type soil (Avg of soft soil and hard soil) all as specified and as directed. |
| 10 | All as per item No 9 above but excavation depth exc 1.50m but not exc 3.00m. |
| 11 | All as per item No 9 above but excavation depth exc 3.00m but not exc 4.50m. |
| 12 | Returning filling in soil including spreading, levelling, watering and well ramming in layers not exc 25cm thick all as specified and as directed. |
| 13 | Removing excavated soil to a distance exc 250m but n exc 500m and depositing where directed at a level not exceeding 1.50m above the starting point all as specified and as directed. |
| 14 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) and PCC haunching if any set in cement mortar, internal dia of pipe 150mm all as specified and as directed. |
| 15 | All as per serial item No 14 above but for 200mm bore pipe. |
| 16 | All as per serial item No 14 above but for 300mm bore pipe. |
| 17 | M&L for 150 mm dia (internal) reinforced concrete pipes, class NP2, laid in trenches over concrete bed, jointed and pointed in cement mortar 1:1 complete all as specified and as directed. Note: Excavation, earthwork and PCC shall be measured and paid seperately under respective item. |
| 18 | All as per serial item No 17 above but for 200mm bore pipes. |
| 19 | All as per serial item No 17 above but for 300mm bore pipes. |
| 20 | M&L for cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates for bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified and as directed. |
| 21 | All as per serial item No 20 above but for 200mm bore pipes. |
| 22 | All as per serial item No 20 above but for 300mm bore pipes. |
| 23 | M&L Cleaning and desludging of drains of C/S not exceeding 0.50 sqm and avg depth of debris/sludge not exceeding 450 mm including removing out all debris/earth/building materials/rubbish and bushes from the drain for smooth functining and disposal of debris out of defence land complete all as specified and directed by Engr-in-charge. |
| 24 | Taking down cement or cement lime plaster from brick/ stone/ concrete walls including raking out joints, hacking for key scrubbing down with water etc all as specified and as directed. |
| 25 | Cleaning of manholes up to 1.50 M depth and taking out sludge, night soil, sludge water etc manually/mechnically and removing the same to distance not exc 1.50 Km out side MoD land and buried underground, working in foul condition complete all as specified and directed. |
| 26 | All as item No 25 here-in-before but depth exc 1.50 M and not exc 3.00 M. |
| 27 | All as item No 25 here-in-before depth exc 3.00 M and not exc 4.50 M. |
| 28 | S&F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed. |
| 29 | S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed. |
| 30 | S&F in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 31 | S&F in repairs, 110mm bore PVC (SWR) bend any radius, with oval access door all as specified and as directed. |
| 32 | S&F in repairs, 75m bore PVC (SWR) bend any radius, with oval access door all as specified and as directed. |
| 33 | S&F in repairs, 110mm bore PVC (SWR) bend any radius, complete all as specified and as directed. |
| 34 | S&F in repairs, 75m bore PVC (SWR) bend any radius, complete all as specified and as directed. |
| 35 | S&F in repairs, 110mm bore PVC (SWR) , branch piece, double (double Y) equal or unequal with oval access door all as specified and as directed. |
| 36 | S&F in repairs, 75mm bore PVC (SWR) , branch piece, double (double Y) equal or unequal with oval access door all as specified and as directed. |
| 37 | S&F in repairs, 110mm bore PVC (SWR) , branch piece, single (single T) equal or unequal with oval access door all as specified and as directed. |
| 38 | S&F in repairs, 75mm bore PVC (SWR), branch piece, single (single T) equal or unequal with oval access door all as specified and as directed. |
| 39 | S&F in repairs 110mm bore PVC (SWR) reducer all as specified and as directed. |
| 40 | S&F in repairs 75mm bore PVC (SWR) vent cowl all as specified and as directed. |
| 41 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregates as in foundations filling and mass concrete all as specified and as directed. |
| 42 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specially provided for complete all as specified and as directed. |
| 43 | M&L for precast reinforced cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in manhole covers including necessary forms and moulds etc and finished surfaces even and smooth without using extra cement complete all as specified and as directed. Note: Reinforcement measured and paid seperately under respective item. |
| 44 | M&L Mild Steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including steel wire anealed not less than 0.9 mm dia or securing with clips, complete all as specified & directed. |
| 45 | M&L for precast cement concrete block masonry with solid blocks of PCC 1:5:8 using 20mm graded stone aggregates, exc 10cm in width and setting in cement mortar 1:6 and including demolition of existing brick work built in cement or cement lime mortar of any description complete all as specified and as directed. |
| 46 | M&L for brickwork with fly ash bricks , straight or curved on plan, exc 6 m mean redius, built in cement mortar 1:6 with and including demolition of existing brick work built in cement or cement lime mortar of any description complete all as specified and as directed. |
| 47 | M&L for cement concrete 1:3:6, type C-1, using 20mm graded stone aggregate as in copings, haunchings and the like including necessary formwork, weathering, slightly rounded or chamfered angles and throating, as directed complete all as spcified and as directed. |
| 48 | M&L for rendering 15mm thick on brick work or stone masonry/ concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement complete all as spcified and as directed. |
| 49 | Labour only for cleaning surrounding areas of septic tank / soakage well including removal of grass, bushes etc along the perimeter of septic tank and soakage well complete all as specified and as directed |
| 50 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 51 | M&L for chequered cement concrete tiles with grey cement and pigment, with glossy finish, rubberized of size 25cmx25cmx25mm /30cm x 30cmx25 mm thick, machine pressed, set jointed and pointed in neat cement slurry over and including 15 mm thick screed bed in CM mortar 1: 6 and pointed in coloured cement to match the tiles complete all as specified & directed. |
| 52 | M&L for PCC 1:2:4, type B1 using 20mm graded stone aggregates as in surface channels and drains complete all as specified and as directed |
| 53 | Extra for forming fair finished drain or channel, 30cm inner girth in cement concrete, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed |
| 54 | Extra for forming fair finished drain or channel, 45cm inner girth in cement concrete, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed |
| 55 | Extra for forming fair finished drain or channel, 60cm inner girth in cement concrete, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed |
| 56 | M&L for 40 mm thick PCC 1:2:4, type B1 (using 20mm graded stone aggregates) as in floor, laid in panels, finished even and smooth without using extra cement complete all as specified and as directed. |
| 57 | M&L for 100 mm thick PCC 1:2:4, type B2 (using 40 mm graded stone aggregate) as in floor, laid in panels, finished even and smooth without using extra cement complete all as specified and as directed. |
| 58 | Dismantling of stone slabs and tiles of any description of thickness in floors, aprons etc laid, bedded and pointed in any mortor all as specified and as directed. |
| 59 | M&L for 75 mm thick PCC 1:4:8, type D-2 (using 40mm stone aggregate) as in sub base of flooring, paving etc complete all as specified and as directed. |
| 60 | M&L for precast cement concrete interlocking tiles 60mm thick factory made, hydraulically pressed cemented tiles with grey cement with pigments, chamfered edge, with glossy finish, rubber moulded of M-35 grade conforming to IS-15658-2006 of approved colour, design, pattern, size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directedNote : Size, shape & pattern of tiles shall be as approved by GE. |
| 61 | M&L for precast cement concrete interlocking tiles 80mm thick factory made, hydraulically pressed cemented tiles with grey cement with pigments, chamfered edge, with glossy finish, rubber moulded of M-40 grade conforming to IS-15658-2006 of approved colour, design, pattern, size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directedNote : Size, shape & pattern of tiles shall be as approved by GE. |
| 62 | Fixing only cement concrete paver block as in footpath,parks,lawns,drive ways or light traffic parking etc,over and including 25mm thick compacted bed of coarse sand,compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and as directed.Note; Old cement concrete paver blocks of any type and size retrived from dismatling shall be resued under this item. |
| 63 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 64 | M & L preparation new plastered surfaces/ concrete surfaces of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 65 | M&L for preparation of old treated surfaces of walls by washing, rubbing down & stopping of painted surfaces and applying one coat of cement base paint, in any colour complete all as specified and as directed. |
| 66 | M&L for preparation of old treated surfaces of walls by washing, rubbing down & stopping of painted surfaces and applying two coat of cement base paint, of shade as approved complete all as specified and as directed. |
| 67 | Supply and fix stack clamp made out of 50mm by 3mm flat iron and 16 mm dia round iron stays fixed to pipe of bore 110mm complete all as specified and as directed. |
| 68 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises all as specified and directed. |
| 69 | M&L for coloured non-skid ceramic tiles, 7 to 8 mm thick (square or rectangular), area of each tiles exc 0.06 Sqm but n exc 0.11 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over & including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.Note :- Colour and shade shall be approved by Engr-in-Charge. |
| 70 | M&L for glazed coloured ceramic tiles in vertical surfaces as in dado of size 450mm x 300mm x 6-7 mm thick, set and jointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4, on other than fair faces of brick work etc complete all as specified and as directed.Note :- Colour and shade shall be approved by Engr-in-Charge. |
| 71 | SS&F in repair Vitreous China, Squatting pan Orissa pattern size 580 x 440mm, white with integral foot rests (excluding flushing cistern and flush pipe) with Vitreous China ‘P’ or ‘S’ trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe, including PCC (1:2:4) type B-1 for fixing of WC and making good the floor to match the existing complete all as specified and as directed. |
| 72 | S&F in repairs, vitreous china wash down water closet (pedestal pattern) white, including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws, etc. complete all as specified and as directed.Make: Cat No. S1053102 of CERA or equivalent model of makes specified. |
| 73 | S&F SS Grating with square frame (Grating thk- 1mm & frame thk- 1.5mm) of size 125mm (minimum) with/without waste-hole complete all as specified and directed. Note: Design of grating to be approved by Engineer-in-Charge. |
| 74 | S&F in repairs, 75 mm dia PVC(SWR) nahani/floor trap with grtaing including jointing to waste pipe with solvent cement,complete all as specified and as directed. |
| 75 | S&F SGSW pipes of grade 'A' internal dia 150 mm, of approved make, laid in trenches over PCC beds and jointed & pointed in CM 1:1 complete all as specified and directed. (PCC shall be measured and paid for seperately under respective item). |
| 76 | S&F SGSW pipes of grade 'A' internal dia 200 mm, of approved make, laid in trenches over PCC beds and jointed & pointed in CM 1:1 complete all as specified and directed. (PCC shall be measured and paid for seperately under respective item). Please Enable Macros to View BoQ information |