| 1 | Repairs, maintenance and operation of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules. a) Electrical Installations, Lights/Fans/Plug Points/Power Points and Street/Compound lighting arrangements as per I.E. b) Substation, Panel Roomc) Water Pumps d) Feeder pillars/LT panels maintenance e) Operation of DG sets, Air conditioners etc. installed in the building.f) any other related work as directed by site Engineer02 nos. skilled Electricians, and 01 no. unskilled helper to assist in Electrical Mechanical related works etc. as required on site.Skilled Electricians:- 02 nos.Unskilled helper:- 01 no. |
| 2 | Materials (as and when Required) |
| 3 | Supply of 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 4 | Supply of 2.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 5 | Supply of 4.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 6 | Supply of 6 A, to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 7 | Supply of 20 A, to 32 A, ratings, DP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 8 | Supply of 63 A, ratings, TPN MCB, \\"C\\" curve, 10 KA breaking capacity |
| 9 | Supply of 4 pole MCCB, rated current 400A having breaking capacity of 36kA at 415 V, 50 Hz. Service Breaking Capacity (Ics)= 100% of Icu, along with Phase Separators (Barriers) and Spreader Terminals etc. as required. |
| 10 | Supply of 3 pin, 5 A ceiling rose complete as required. |
| 11 | Supply of 20 mm medium class PVC conduit complete as required. |
| 12 | Supply of Power Cables, Solid Aluminum Conductor & Balance Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 or equivalent, etc. as required.3.5 x 150 sqmm Aluminium Armoured Cable |
| 13 | Supply of Call Bell suitable for single phase, 230 V, complete as required. |
| 14 | Supply of 3-Pin Plug Tops with Indicators:- |
| 15 | 15/16 Amp |
| 16 | 5/6 Amp |
| 17 | Supply of DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete as required. |
| 18 | Supply of 90 Watt Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 19 | Supply of 150 Watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 20 | Less Credit for scrap items for old dismantled/ obsolete items Please Enable Macros to View BoQ information |