| 1 | Supply and installation of 200 watt LED floodligths Model: LFLN-200-CDL/60M,Make Crompton , Havell, Phillips, Bajaj Efficacy> 110 LPW Warranty 5 Years luminaire comprises of die cast aluminium housing, control gear compartment, frame with toughened glass. Size 390x310x66 mm LED Floodlight 200 watt,complete in all respects as approved and desired by the Engineer in charge at site. |
| 2 | S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (CCurve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-incharge:- Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (CCurve, 10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) 34.26 B(i)(a) (Rs. 14581.00+5.35%=Rs. 15361.10) |
| 3 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Double Pole 6-32amp. (10kA, Curve-C) 34.16 A(vi) (Rs. 408.00+50%=Rs. 612.00+5.35%=Rs. 644.74) |
| 4 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- Overall size 10sq.mm (4Core) Armoured (Underground) 34.10 A (xxxvi) (Rs. 392+30%=Rs. 509.6+5.35%=Rs. 536.86) |
| 5 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Triple Pole 40amp. (10kA, Curve-C) 34.16A (xi) (Rs. 836.00+50%=Rs. 1254.00+5.35%=Rs. 1321.10) |
| 6 | Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation , stringing and jointing of pipe upto 160mm complete 28.71 (Rs. 850.46+5.35%=Rs. 895.96) |
| 7 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) 34.37 A (iii) (Rs. 189+5.35%=Rs. 199.11) |
| 8 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed) 34.09 (ii) (Rs. 18+60%= 28.8+5.35%=Rs. 30.34) |
| 9 | Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- TP&N Horizontal Double Door Distribution Board 4 way each 34.17(v) (Rs. 2406.00+15%=Rs. 2766.90+5.35%=Rs. 2914.92) Please Enable Macros to View BoQ information |