| 1 | M & L for concealed/surface conduit wiring with 2 x 2.5 sqmm (Nominal area) single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable drawn through in and including FRLS PVC Conduit medium grade with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. Note :- (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. (b) working hight upto roof level of wksp buildings for item No- 1 only |
| 2 | All as per item No. 1.00 above, but cable of size 2 x 6.0 sqmm and earth wire 1x 6 sqmm |
| 3 | All as per item No. 1.00 above, but cable of size 2 x 10.0 sqmm and earth wire 1x10 sqmm |
| 4 | All as per item No.1.00 above, but cable of size 4 x 10.0 sqmm and earth wire 2x10sqmm. |
| 5 | Supply and laying in trenches/ surface/wall/trusses PVC insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 16 Sqmm 3 core and connection complete with aluminium cable lugs incl dismantling taking down unsv one all as specified and directed. |
| 6 | S&F 6 Amp Modular switch flush type single pole one way incl dismantling taking down unsv one all as specified and as directed |
| 7 | S&F bell push modular type one way 6Amp, 240 volt incl dismantling taking down unsv one . all as specified and as directed |
| 8 | S&F modular socket outlet 3 pin 6 amps, 230v incl dismantling taking down unsv one all as specified and as directed |
| 9 | S&F modular switch socket combination multipurpose 2-in-1 flush type 3 pin 15 amps and 3 pin 5 amps, 230v incl dismantling taking down unsv one all as specified and as directed |
| 10 | S&F modular electronic fan regulator with 5 step type,120 W, AC 240 Volts, two module, 50 Hz incl dismantling taking down unsv one all as specified and as directed. |
| 11 | S&F ceiling rose surface Bakelite three terminal incl dismantling taking down unsv one all as specified and as directed. |
| 12 | S&F bell electric AC 240 volt, 50 HZ. incl dismantling taking down unsv one all as specified and as directed. |
| 13 | S&F modular coverplate with support plate for upto 4 modules including anodised metal/pvc boxes & dismantling taking down unsv one all as specified and as directed. |
| 14 | S&F modular coverplate with support plate for upto 8 modules including anodised metal/pvc boxes & dismantling taking down unsv one all as specified and as directed. |
| 15 | S&F modular coverplate with support plate for upto 16 modules including anodised metal/pvc boxes & dismantling taking down unsv one all as specified and as directed. |
| 16 | S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed. |
| 17 | S&F MCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed. |
| 18 | S&F MCB, Double Pole,63 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed. |
| 19 | S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismantling taking down unsv one all as specified and directed. |
| 20 | S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismantling taking down unsv one all as specified and directed. |
| 21 | S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 12 way incl dismantling taking down unsv one all as specified and directed. |
| 22 | S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismantling taking down unsv one all as specified and directed. |
| 23 | S&F Vertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 8 way incl dismantling taking down unsv one all as specified and directed. |
| 24 | S&F MCCB, 36KA, 3 pole, with thermal magnetic trip unit, rated current 160amps complete with spider link incl dismantling taking down unsv one all as specified and directed. |
| 25 | S&F Metal plug and socket board with MCB SP 20 amp, 16 KA incl dismantling taking down unsv one all as specified and directed. |
| 26 | M & L for concealed/surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including FRLS PVC Conduit medium grade or PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including galvanised sunk metal terminal box fixed flush to wall with 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer for mounting of switch, regulators or bell push, ceiling rose/ holders etc incl necessary chase cutting for conduits and sinking boxes and making good to walls,floors etc complete all as specified and directed dismantling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed. |
| 27 | All as per item No. 27.00 above, but for one 5 amps socket point independent all as specified and directed. |
| 28 | All as per item No. 27.00 above, but for one 5 amps socket point in same board all as specified and directed. |
| 29 | All as per item No. 27.00 above, but for one 15 amps socket point independent with 2.5 sqmm cable and 2.5 sqmm earth wire all as specified and directed. |
| 30 | S&F Metal Plug 20amps, 2 pole, 230V all as specified and directed.Make :- Schneider, Cat No-AP10 or equivalent of Legrand/L&T/ABB. |
| 31 | S&F LED batten with LED tube, 2'long, 10 watt, CDL, 230 Volts , complete with all accssories internally pre wired incl dismantling taking down unsv FTL/CFL fiitings all as specified and directed. |
| 32 | Supply & Fix LED baten, 20/22watt, 230 Volts, 4 feet long , complete with all accssories internally pre wired incl dismantling taking down unsv LED fiitings all as specified and directed. |
| 33 | Supply & Fix Square shaped recess mounted LED slim panel down lighter, 40 watt (2`x2`), to POP/grid celing/surface complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismantling taking down unsv fiitings any type all as specified and directed. |
| 34 | S&F LED recessed round or square polycarbonate housing down lighter with superior light output and integral driver , 10/12 watt, complete with fixing spring clip 2 nos, fixed flush to gypsum/grid ceiling incl dismantling taking down unsv one any type all as specified and directed. |
| 35 | S&F 10W Bulk head light fitting including taking down old unsv one all as specified and directed. |
| 36 | M & L for Earthing complete with GI Pipe electrode, 40 mm bore, Medium grade, 2.5 mtr long buried directly and vertically in ground with top edge at ground level after making manual bore hole of size not less than 300 mm dia and 2.65 Mtr long near the specified bldg, connected with galvanised steel strip earthing lead of size 32mmx 6mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 80mm thick with handle for lifting made out of 8mm dia MS rod, wiremesh, charcoal and salt in alternate 150mm thick layers around CI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion after dismantling taking out unserviceable one.. Please Enable Macros to View BoQ information |
| 37 | M & L for Earthing complete with GI Pipe electrode, 40 mm bore, Medium grade, 2.5 mtr long buried directly and vertically in ground with top edge at ground level after making manual bore hole of size not less than 300 mm dia and 2.65 Mtr long near the specified bldg, connected with galvanised steel strip earthing lead of size 32mmx 6mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 80mm thick with handle for lifting made out of 8mm dia MS rod, wiremesh, charcoal and salt in alternate 150mm thick layers around CI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion after dismantling taking out unserviceable one.. Please Enable Macros to View BoQ information |