| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness complete all as specified and directed. |
| 2 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws complete all as specified and directed. |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 5 | S&F 0.71 mm thick plain pre-coated Galvalume steel, (matching Sandwich Mangalore Pattern profile) factory made, hips, valley gutter, drip and strainght flashing (length and girth as fixed) etc complete all as specified and directed by Engineer-in-Charge. |
| 6 | Dismantling boarding, any description, fixed in any position if fixed with screws / nails complete all as specified and directed. |
| 7 | M&L for factory made PVC desighner weather board 18 to 20 mm thick, 300 mm wide, (density not less than 650kg/cum) fixed at eaves level of roof sheeting with screws/ fasteners including all necessary fixing arrangement, complete all as specified and directed. |
| 8 | Dismantling timber scantling 40 Sqcm and over in section and at any position as in unframed work complete all as specified and directed. |
| 9 | M&L for 2nd class hard wood in scantling exc 40 Scm in area clean sawn for unframed work complete all as specified and directed. |
| 10 | Fixng Only for IInd class hard wood in scantling clean sawn for unframed work complete all as specified and directed. |
| 11 | Dismantling timber scantling under 40 Sqcm in section and at any position as in unframed work complete all as specified and directed. |
| 12 | M&L for 2nd class hard wood plain fillets section exc 13 Sqcm and not exc 25 Sqcm, square,rectungular or tringular in section, clean sawn, secured with nails or brads for unframed work complete all as specified and directed. |
| 13 | Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with raw linseed oil complete all as specified and directed. |
| 14 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 15 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed. |
| 16 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 17 | M&L for new or previously treated surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 18 | M&L for complete removal of exisisting treatment of truss and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 19 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 20 | M&L precast cement concrete block masonry exc. 10 cm width with solid blocks of PCC ,type C 1 1 :3:6(20mm graded agg)and setting in cement mortar (1:6) complete all as specified and directed. |
| 21 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 22 | S&F 20mm thick second class hardwood, boarding as in ceilings,clean sawn with butt joints & fixed with nails in any situation complete all as specified and directed. |
| 23 | Repairs to replace old and or decayed boarding in patches including cutting out old, piecing, heading joints, etc complete all as specified and directed. |
| 24 | M&L for painting two coats of Synthetic enemal paint over a coat of pink primer on new wooden surfaces complete all as specified and directed. |
| 25 | M&L one coats of synthetic enamel painting to wooden surfaces including preparation of old surfaces complete all as specified and directed. |
| 26 | Providing & fixing false ceiling at all heights 12mm with semi perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisturecontent less than 2%, humidity resistance\ of 99%, NRC O.50 to 0.75 as per IS8225:1987, Noncombustible as per BS476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in truehorizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqmincluding both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended fromceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threadedhanger rod upto 1000mm length and L shape level adjuster ofsize 85x25x2mm. Galvanised iron perimeter wall angle ofsize 24x 24x0.40mm of length 3000 mmto be fixed on periphery wall / partitionwith the help of plastic rawl plugs at 450mm center to center and 40mm long drywall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 27 | Taking down cement plaster of any description incl racking out joints hacking for key and scrubbing down with water to remove dust etc complete all as specified and directed. |
| 28 | M&L for 15 mm thick rendering on brickwork / concrete surface on wall finished even and smooth (without using extra lime or cement in CM 1:4 using liquid water proofing compound @ 200ml of 50kg of cement, all as specified and directed by Engr-in-ChargeNote:- LWPC shall be measured & paid seperately. |
| 29 | Supply only liquid water proofing compound complete all as specified and directed. |
| 30 | M&L for complete removal of existing treatment form wall to make the surface free from dust, loose paint and loose plaster by scrapping manually / mechanically and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over 3mm thick wall care putty on wall surfaces complete all as specified and directed. |
| 31 | M&L for preparing old surfaces of walls plastered or un-plastered by brooming down with steel or wire brush and scraping down smoke soot, moulds moss & efflorescent salt and trading oil and greasy spots , washing rubbing down and stopping of distempered and painted surface & removing all vegetation growth, nails and making good holes,cracks etc complete by necessary putty and make the surface smooth by rubbing with sand papers etc and applying one coat of distemper oil emulsion on old prepared surfaces of walls complete all as specified and directed. |
| 32 | M&L for preparation of old decorated plastered or unplastered surfaces of ceiling, cornices etc by brooming down or steel wire brushing down scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of oil bound distemper complete all as specified and directed. |
| 33 | M&L for Preparing New plastered surfaces of wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over 3mm thick wall care putty on wall surfaces complete all as specified and directed. |
| 34 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 35 | S&F rainwater PVC (SWR) 110mm dia pipes as in single socketed in any length with rubber ring joints fixed to walls with heavy duty double sided clamp (Shaivi or equivalent) by interval not more than 2.00m Complete all as specified and directed. |
| 36 | S&F for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall/floors with heavy duty double sided clamp (Shaivi or equivalent) by interval not more than 2.00m Complete all as specified and directed. Notes : (i) Safety precautions scaffolding and safety measures like rope, safety belts, helmets, ladder etc shall be responsibility of contractor.(ii) Necessary scafolding required deemed to to included in rates quoted.(iii) The wk is to be carried out any height of bldg. |
| 37 | Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles complete all as specified and directed. |
| 38 | M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of size 350x250x7mm/ 450x350x7mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed. |
| 39 | M&L for non skid Ceramic tiles,first quality( of approved class , colour and design/ shade ) 6 to 7 mm thick( square/ rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, ,as in floor surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over with and including 15 mm Screed bed in Cement mortar 1: 6 Complete all as specified and directed. |
| 40 | S&F in repair white vitreous China wash down water closet pan (pedestal) pattern, and trap (excluding) fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. with and including plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device and 15mm dia chromium plated brass washing jet fixed to water closet with 15mm dia and 1.2m to 1.5m long flexible pipe with chromium plated spring type cover complete with fixing arrangement fancy look complete all as specified and directed. |
| 41 | S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest (excluding flushing cistern and flush pipe) & including CI trap & connecting fitting as required set in plain cement concrete (1:3:6) type C-1 and connecting to flusing cistern and trap & connecting fittings as required and making good to floor, complete all as specified and directed. |
| 42 | S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed |
| 43 | Taking down Cast iron/PVC pipe of any dia and size fixed on wall or floor including all fittings complete all as specified and directed. |
| 44 | S&F 110mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed. |
| 45 | S&F 110 mm dia PVC(SWR) bends/ shoes any radius complete all as specified and directed. |
| 46 | S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 47 | S&F 75 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed. |
| 48 | S&F 75 mm dia PVC(SWR) bends/ shoes any radius complete all as specified and directed. |
| 49 | Disconnecting & taking down existing water tank of capacity exc 250 litr and not exc. 500 litre and removing from site complte and S&F rotational meoulded polyethylene water storage tanks 500 lts capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed. |
| 50 | Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc., capacity of tank exc 250 & n exc 500 litres including writing date of cleaning on the tank with suitable synthetic enamel paint etc complete all as specified and directed. |
| 51 | Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc., capacity of tank exc 5000 & n exc 10000 litres including writing date of cleaning on the tank with suitable synthetic enamel paint etc complete all as specified and directed. |
| 52 | M&L for Cleaning of septic tank up to 25 users by removing sludge in semi solid sate or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5 km but n exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 53 | M&L for Cleaning of septic tank exc 25 users and not exc 50 users by removing sludge in semi solid sate or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5 km but n exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 54 | M&L for Cleaning of septic tank exc 50 users and n.exc 100 users by removing sluge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 55 | M&L for Cleaning of septic tank exc 100 users and n.exc 200 users by removing sluge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 56 | M&L for Cleaning of septic tank exc 200 users and n.exc 300 users by removing sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 57 | M&L for Dewatering of soak well or sewage of any dia and depth manully or by using pumps and rremoval of sludge if any to a distance exc1.5km but not exc 2Km out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 58 | M&L for cleaning with suitable chemical of P/S trap of WC/IWC etc by removing all blockage of any description in any situation in the system and removal of sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out ofMOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 59 | M&L for cleaning of Nahani/floor trap of Bath/kitchen/urinal incluing Ist gully trap etc by removing all blockage of any description in any situation in the system and removal of sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out ofMOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 60 | M&L for cleaning of Sewage pipe line from gully trap to ISt manhole an then upto the final drop into the septic tank an soak well /cess pool (except intermediate manholes ) by removing all blockage of any description in any situation in the system complete any ia of pipe an epth by rodding ,manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out ofMOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 61 | M&L for cleaning of manholes any type-size and any depth by removing of sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out ofMOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 62 | Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed. |
| 63 | M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dollycomplete all as specified and directed for one light/Fan point controlled by one Switch. |
| 64 | All as per Srl item No 63 above but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed. |
| 65 | All as per Srl item No 63 above for point wiring for one light point controlled by two way switch complete all as specified and directed. |
| 66 | All as per Srl item No 63 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed. |
| 67 | All as per Srl item No 63 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.omplete all as specified and directed. |
| 68 | All as per item No 63 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed.Make of cable and conduit: Havells/ Plaza/ Kalinga. |
| 69 | All as per item No 63 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed. Make of cable and conduit: Havells/ Plaza/ Kalinga. Please Enable Macros to View BoQ information |
| 70 | All as per item No 63 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed. Make of cable and conduit: Havells/ Plaza/ Kalinga. Please Enable Macros to View BoQ information |