| 1 | Demolition above G.L. upto floor two level including disposal of unserviceable materials within 20 metres lead and including cutting the necessary reinforcement and separating out from R.C.C. /R.B. works:- |
| 2 | Excavation in foundations in all kinds of soil such as pick work ,jumper work, blasting hard or soft rock chiseling where blasting is prohibited or saturated soil , lift upto 1.50 mtr stacking the excavated soil not more than 3.00 mtr clear from the edge of the excavation and then returning the stacked soil in 15 cm layers when required into plinth sides of foundation consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth as directed with a lead of 20 mtrs. P/J Work . |
| 3 | Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) excluding cost of centring & Shuttering in. |
| 4 | Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centring, shuutering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 Mtrs. and removal of the same for insitu-reinforced concrete & plain concrete work in: |
| 5 | Vertical surfaces such as walls (any thickness) partitions and the like including attached pillaster buttresses, plinth and string courses and the like with in all leads and lifts. |
| 6 | Providing and laying cement concrete 1:1.5:3 (1cement :1.5 sand :3 graded stone aggregate20mm. nominal size) and curing complete excluding cost of form work and reinforcement for feinforced concrete work in: |
| 7 | Wall (any thickness but not less than 0.1 m thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level upto floor two level : |
| 8 | Providing tor steel reinforcement for RCC work including bending binding and placing in position complete upto floor two level to the entire satisfaction of the Engineer in charge.Tor steel with in all leads and lifts. |
| 9 | Providing & erecting MS rectangular water storage tank with ISMC wall stiffeners, complete. |
| 10 | Supply and applying FRP ( Fibre Reinforced plastic) lining/coating to internal surface of MS tank including surface preparation by grinding, cleaning, degreasing etc. application of FRP laminate using glass fibre mat (minimum 450 GSM), isophthalic polyester/ vinylester resin with reqired catalyst and hardener, hardener, finishing with UV-resistant top coat, including all consumables such as brushes, rollers, PPE, labour charges, testing curing including GST and freight, complete ai all respects as per specifications and direction of Engineer-in- Charge. |
| 11 | Supply of 15 KVA KIRLOSKAR LIQUID COOLED SILENT DG SET comprising of KIRLOSKAR make LIQUID Cooled Diesel Engine model 3R550 TC 4G1 (CPCB IV NORMS COMPLIANCE) developing 20.9 BHP@ 1500RPM @ 15 KVA KIRLOSKAR green make Alternator rated at 3 Phase,415 volts, 50HZ; 0.8 p.f @ 1500RPM both mounted, and aligned on a common MS base frame complete, 1 No. Volts DC Battery KIRLOSKAR Battery Leads, 1st fill of Lube oil,and other features like: Ease of information; QR enabled Genset Superior Look: New attractive color scheme Multicolour Genset Status Indicator Silencer Indside canopy with compact design AMF as standard design: Auto start Auto Stop (Type A panel) (Auto Changeover in customer's scope) |
| 12 | Providing laying and fixing of aluminium conductor, PVC insulated and PVC sheathed armoured /XLPE power cable, working voltage 1100 volts grade on surface etc, of the required size 3.5850mm 2. |
| 13 | Providing and fixing 100 ampere change over switch of make L&T as required complete in all respect including all connection with thimbles etc. complete. |
| 14 | Providing double loop earthing arrangement with copper earth plate 600mmx3mm thick including accessories i.e. G.I. pipe coper plate, Copper strip and wire for looping and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (butt without charcoal or coke and salt) complete as required. Extra for using salt and charcoal for G.I or copper plate earth electrode complete as required.Providing and fixing 25mmx5mm G.I. strip on surface or in recess for earth connection etc. as required |
| 15 | Excavation in foundations trenches etc. in earth work right work right upto 1.5m and 10cm returning and laying cement concrete 1:4:8 (1 cement 4 sand 8 graded stone aggregate 25mm nominal size) and curing complete excluding cost of form work in foundation and plinth in breast retaining wall and including cement concrete flooring 1:2:4 (1 cement 2 sand 4 gradedstone aggregate 20mm nominal size) n layer finished with a floating coat af neat cement 40mm thick. (i) Foundation size 2.0mx1.0x0.7m(0.3mtr above G.L & 0.4 mtr below G.L.) |
| 16 | Providing and fixing fire extinguishers of surperior class make as per IS specification |
| 17 | Providing and fixing rubber mat suitable and tested upto 1100 volt AC Supply having size 2mx1mx12mm thick. Please Enable Macros to View BoQ information |