| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: Executive Engineer(E) PWD M-253 Name of Work:- RMO of Electrical and Mechanical services installations at SRCASW, Vasundhara Enclave, Delhi. (Sub Head:- Repairing of EI including replacement of fan & fittings, pumps) NIT No.:06/EE(E)/PWD M-253/2026-27 Estimated Cost:-18,72,895/- Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Sub Head Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | DSR-2025 ITEMSWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C |
| 4 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 5 | 6 x 1.5 sq. mm |
| 6 | 3 x 4 sq. mm |
| 7 | 6 x 4 sq. mm |
| 8 | 3 x 6 sq. mm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 10 | 25 mm |
| 11 | Supplying & fixing following size PVC trunking along with cover & accessories on surface etc. complete as required.38 mm x 25 mm |
| 12 | 50 mm x 50 mm |
| 13 | 100 mm x 50 mm |
| 14 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 15 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 16 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door |
| 17 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 18 | Supplying and fixing following rating, 240 / 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A TPN MCB |
| 19 | 63 A TP MCB |
| 20 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A, 16 KA,TPMCCB |
| 21 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).36 watt |
| 22 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)36 watt |
| 23 | Supplying, installation, testing & commissioning of 34 to 36 Watt surface mounted LED luminaire of size 1200mm X 300mm (N.S) with white powder coated CRCA housing with PC Diffuser & integrated electronic driver having following specifications i/c suitable mounting arrangement, making connection with 1.5 sq mm FRLS PVC insulated copper conductor cable and earthing complete as required. Lumen output: ≥3800 lumensSystem efficacy: ≥105 <120 lm/WattCRI: ≥80CCT: 5500-6500kLife: 50000hours @L70THD: ≤10%Surge protection: ≥2.5KVDriver efficiency: ≥85%Power factor: ≥0.95Voltage range: 160-270V |
| 24 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 25 | Supplying, laying & fixing of following size one number XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 kV grade conforming to IS 7098 (Part 1) 1988 on existing cable tray / wall surface as required.3 x 10 sq. mm |
| 26 | 4 x 25 sq.mm. |
| 27 | Supplying and Fixing, testing & commissioning of 'B' class medium duty G.I. pipe in existing borewell conforming to IS 1239 including welding, fittings lowering and welding of GI Flange, soot safeda etc complete as required:50 mm dia |
| 28 | Supplying & replacement of 5 HP 3.70 kW Borewell submersible Pumps having head range 83-150 Mtr. with discharge 150-70 LPM suitable for operation on 415 Volt 3-Ph 50 Hz AC supply in the existing borewell i/c water & electrical connections etc. complete including credit for dismantled material under buy back etc. as reqd. |
| 29 | Providing & fixing of 6mm thick PVC coated steel wire rope with the existing pipe of submersible pump etc complete as reqd. |
| 30 | Providing & laying of the following size PVC insulated PVC sheathed copper conductor flat submersible cable in the existing pipe of submersible pump etc complete as reqd.3 core X 10 Sq.mm. |
| 31 | Supplying & fixing of 5HP 3.7KW, B38 415V, 50 Hz AC Submersible pump controller Key Features: Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1. Protections Offered - Overload, Single Phasing, Phase reversal, Phase imbalance. Auto Restart Feature. Vibration proof enclosure with IP54 protection class. Indications Offered - ON/OFF, Voltage and Ampere. Compatible with M-POWER., connection etc as reqd. q |
| 32 | Repairing of 20 HP 20HP Dewatering submersible pump, having head range 12-24 Mtr. with discharge 3790-1420 LPM suitable for operation in the existing tank i/c lifting from the tank, supplying & replacement of defective components, rewinding of motor, water & electrical connections, lowering in the tank, testing, etc. complete including credit for dismantled material under buyback, etc. as reqd. |
| 33 | Providing and laying in position M-20 (1:2:4) reinforced cement concrete foundation of size 600 mm (L) x 600 mm (W) and 1000 mm (D) i/c excavation of earth, providing cutting, bending and placing in position, reinforcement TMT bars of 12 mm dia -1100 mm long (approx)-8 nos. and reinforcement ring of cold twisted bar of 8 mm dia - 2200 mm (approx) - 6 nos. (with 150 mm spacing) as required, supplying & positioning fixing of 4 Nos 20 mm diameter x 700 mm long GI foundation bolts (EN8 Grade) with nuts, check nuts & washers including template and providing 63 mm (O.D.) DWC HPDE pipe for cable entry and exit as reqd. |
| 34 | Installation of existing 6M height octagonal pole including dismantling from the existing foundation, dismantling of existing foundation & dispossing off the malba, reinstalltion of pole on the new foundation including nut bolts, connections etc. complete as required. Total in Figures 1872895.0 33600.0 Eighteen Lakh Seventy Two Thousand Eight Hundred & Ninety Five Only Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |