| 1 | Supplying & erection of flange mounted hot dip galvanized octagonal poles of 12 mtrs. height made from 3 mm thick HT steel plate having bottom dia of 200-240 mm & top dia of 90-100 mm complete with window sleeve type cover/door (flush with exterior surface and shall have suitable locking arrangement) at a height of 2.5 mtrs from the base for cable termination block etc. and galvanized base plate of size 320 mm x 320 mm x 20 mm thick complete etc as reqd. Provision should be provided in the bottom compartment to mount PVC/Bakelite sheet along with connectors for cable looping and single pole MCB to isolate individual luminaire i/c disconnections of cable from old poles and connection of existing cable to new poles etc as required. |
| 2 | Supplying & erection of flange mounted hot dip galvanized octagonal poles of 10 mtrs. height made from 3 mm thick HT steel plate having bottom dia of 200-240 mm & top dia of 90-100 mm complete with window sleeve type cover/door (flush with exterior surface and shall have suitable locking arrangement) at a height of 2.5 mtrs from the base for cable termination block etc. and galvanized base plate of size 320 mm x 320 mm x 20 mm thick complete etc as reqd. Provision should be provided in the bottom compartment to mount PVC/Bakelite sheet along with connectors for cable looping and single pole MCB to isolate individual luminaire i/c disconnections of cable from old poles and connection of existing cable to new poles etc as required. |
| 3 | Pdg. & making RCC foundation of following size with M.20 grade concrete with foundation bolt set 750 mm x 24 mm dia J-Bolt for reinforcement along with centering & shuttering i/c anchor of size M 16 along with template suitable for 10/12 mtr pole complete with excavation the soil & refilling ramming, curring etc as reqd of size 500mm x 500mm x 1000mm (800 mm below ground level & 200 mm above ground level) (The foundation drawing shall approved by the Engineer-in-charge) |
| 4 | Supplying & fixing of Galvanized Overhang 1000mm long bracket made from 48.3 OD ERW pipe for street light Octagonal pole of following arms etc. as reqd. The design shall be approved engineer incharge . |
| 5 | Single Arm |
| 6 | Double Arm |
| 7 | Supplying, Installation, Testing & Commissioning of SMC pole Box of size 250mm x 200mm x 105mm with hinged cover on surface/ recess/pole complete with aluminium connector strip - 2 Nos, MS Clamp - 2 Nos., 6-32amp. C series SPMCB- 1 No., having IP: 66 protection connection etc. as reqd. |
| 8 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required |
| 9 | Supplying & Laying following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade in existing DWC/GI/pipe/on surface / ground or loose for connection and testing etc as reqd. |
| 10 | 4 x 16 sq mm |
| 11 | 4 x 25 sq mm |
| 12 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.. |
| 13 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 14 | 150 watt |
| 15 | 200 Watt |
| 16 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 17 | 200 watt |
| 18 | Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required. |
| 19 | Supplying and Drawing i/c connections & interconnections of following sizes of PVC Insulated and PVC Round Sheathed Multi Core Flexible Aluminium Conductor Heavy Duty Industrial Cables for Voltage Grade 1100 Volts as per IS: 694:2010 for interconnection from window to fitting of street light pole and high mast pole height of upto 30 mtrs.etc complete as reqd. |
| 20 | 3 x 4 sq.mm |
| 21 | SITC of 16 Mtr high mast shaft in two sections suitable for 50m/sec wind speed, with head frame, winch mounting bracket, luminaries carriage suitable to install 8 nos. LED luminaries up to 400 Watt in Symmetrical arrangement (0-360deg.), including supply and fixing of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual, handle, junction box, lightening finial including Construction of shallow foundation with M25 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour erecting of the same with special arrangements/ scaffolding complete with following accessories/jobs:- (i)The pole shall have following or better specifications: -Top Dia 150 mm and base Dia 410 mm, thickness of hot rolled steel plate at top 3 mm and bottom 4mm minimum, size of opening door should be 1200 mm x 250 mm, cross section pole 20 side polygon and Dia meter of base plate 570 mm and thickness 25mm, 8 nos. foundation bolts Dia 30 mm and length 850 mm, manufactured from special steel along with Nut, Washers, Anchor plate and common template i/c Suitable size steel reinforced CC foundation as per manufactures/ BIS specifications and standards.(ii) LED Aviation light as per Standards(iii) Supply of outdoor type stand mounted feeder pillar (IP 55) with 63A TPN MCB incomer, single dial time switch, 45A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, including Supplying and laying copper conductor unarmoured trailing cable from feeder pillar to respective luminaire up to 30 meter and all other required accessories. |
| 22 | Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 23 | 1 output per phase and suitable for single phase supply |
| 24 | Fabrication, supply, installation, testing and commissioning of MV compartmentalized type outdoor type double door with centre lock and also having external lock arrangement cubical feeder pillar panel, having front area not less than 1.6 sqmtr. having 400 mm depth, made out of 2 mm thick CRCA sheet with 300 Amps rated 4 strip aluminium busbar, free standing totally enclosed dust and vermin proof, suitable for operation on 3 phase 415 V, 4 wire AC supply system, having suitable cable entry arrangement with detachable gland plates, duly powder coated, interconnection with suitable size aluminium strips / bars connections, earthing labelling, quarter turn knobs, etc. with cable chamber, busbar chamber conforming to section-4 of CPWD specification for Electrical works part IV Substation 2013 etc., complete with fixing of panel on MS stand of size 50 mm x 50 mm x 6 mm thick and 1000 mm height angle iron framework grouted 500 mm deep in CC foundation i/c painting of MS frame work with synthetic enamel paint etc. as reqd. Incomer = a) 250A 4P MCCB, 415V, 36 kA (Icu=Ics), with Thermal Magnetic release (b) Metering compartment: Digital Multifunction meter (having basic parameters: Amps, Volts, W/VA, KWh /KVAh ) set of CTs - 1 Set c) Phase indicating lamps(LED type) with toggle switches, control fuses etc. - 1 set Outgoings: ) a) 250 A Power contactor three pole with 415 volt AC supply - 1 Nos. b)125 A TP MCCB, 415 V, 25 kA (Ics = Icu), with adjustable thermomagnetic release - 3 Nos. c) Astronomical time switch capable of automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF) in feeder pillars / Lighting DBs for three phase supply - 1 No. d) GI earth strip of suitable size to full width of cubicle panel with two earth studs at the ends as required - 1set e) Anodised aluminium MV danger notice plates and phenolic labeling as required - 1setdoor hinged should be properly welded on both side for security purpuse. |
| 25 | Supplying, installation, Testing & commissing of 110 Amp. power contractor with connection complete etc. as required. |
| 26 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 27 | Credit of old dismantle material (i/c labour for dismantling) |
| 28 | Aluminium cable / wire upto 35 sq.mm |
| 29 | Assorted size LED Fittings 150/180/200/ 250 watt |
| 30 | Assorted size upto 16 mtr high mast |
| 31 | Feeder Piller Please Enable Macros to View BoQ information |