| 1 | Labour for dismanteling all members of the timber bridge (except piles) and stacking them at sutiable places as directed( all members will be under custody of the contractor till taken over by th department.)scarfing and joining piles 25 cm to 30 cm dia Dressed to heartwood 90 cm. In length includng supplying, fitting and fixing with 2 nos. of 50 mmX 10 mm MS FI clamps and 16 mm dia MS bolts and nuts etc. complete as directed |
| 2 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.I. ordinary soil. By Manual Means. (I) Without dewatering. Upto 3 m depth |
| 3 | Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999) (Pile diameter-1000 mm) |
| 4 | Levelling course for Pile cap |
| 5 | Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification. C) RCC Grade M30(i) Using concrete mixer. |
| 6 | Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 |
| 7 | Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork(N) without plasticiser G. RCC Grade M30 Case – II : With Batching Plant, Transit Mixer and Concrete Pump |
| 8 | Supplying, fitting and placing Mild steel reinforcement complete in sub-structure as per drawing and technical specification |
| 9 | Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications. |
| 10 | Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (N) Without plasticiserB. RCC Grade M 25, Case I-Using Concrete Mixerii) For T-beam and slab. (b) Height 5m to 10m |
| 11 | Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications.(i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 |
| 12 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications |
| 13 | Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. |
| 14 | Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation |
| 15 | Drainage Spouts complete as per drawing and Technical specification |
| 16 | Construction of temporary Bamboo bridge of 3.70m clear road way with Bholuka or Barua Bamboo post 5nos. in each rows driven at least180cm. below ground level and rows not more than 150cm apart from center to center Bholuka or Barua Bamboo dham longitudinal groth both closely placed and tied with half bamboo 90cm to 120cm apart in both layers and ttwo layers of jati bamboo chattais ( top layer should be digonally woven), 70 mm to 100 mm thick brushwood in between chattias should be tied with half jati bamboo on both ends, bamboo railing with bholuka or barua bamboo post placed at150cm apart jati or betua bamboo hand rails of two lines both side of every alternate rows.All tying must be done with cane or coir string and only mature bamboo should be used in work. |
| 17 | Providing and laying pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and technical specificationsA. Stone/Boulder |
| 18 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification |
| 19 | Providing and laying of boulder apron laid in wire crates made with 4mm dia GI wire conforming to IS: 280 & IS:4826 in 100mm x 100mm mesh (weaved diagonally) including 10% extra for laps and joints laid with stone boulders weighting not less than 40Kg each. |
| 20 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned up to lead of 1000 metres including removal and disposal of top organic soil not exceeding 150mm thickness. By Manual Means. In area of light jungle. |
| 21 | Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirment of table 300-2 ( including compensation of earth.)( Including cost of testing of materials at site and laboratory as directed by the deptt. (a) from private land. |
| 22 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2) (including compensation of earth.)(a), ( Including cost of testing of materials at site and laboratory as directed by the deptt. (a) from private land |
| 23 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density,complete as per cl. 401( with an initial lead of 5 Km.)( Including cost of testing of materials at site and laboratory as directed by the deptt. (ii) for grading- II Material. |
| 24 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. By Manual Means. Grading- III. Using Screening Type-B (11.2mm Agg.). |
| 25 | Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and of specific 28 days compressive strength over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer in charge and in proper level and grade and compacted with appropriate equipment such as plate vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawing and technical specification clause 1504 of MORD. |
| 26 | Providing and Fixing 'Logo' of CMGSY Project Providing and fixing of typical PMGSY informatory sign board with logo as per MORD specifications and drawing. Three MS plates of 1.6mm thick, top and middle plate will be welded with MS flat iron 25mmx5mmx size on back on edge. The lower plate will be welded with MS iangle iron 25mmx5mmx5mm. The anfle iron frame of the lower most plate and flate iron frameof middle plate will be welde to 2 nos. 75mmx75mm of 12SWG sheet tube posts duly embeded in cement concrete M15 grade blocks of 450mmx450mmx600mm, 600mm below ground level . The top most diamond plate will be welded to middle plate by 47mmx47mm of 12SWG steel plate tube . All MS will be stove enameled on both sides. Lettering and printing arrows, bordes etc. will be painted with ready mixed synthetic emnamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted and two coats of epoxypaint as per specification clause 1701 and Annexure 1700.1 i) PMGSY Logo Board @ 2.0 KM Interval |
| 27 | Supplying,fitting and fixing RCC guard post size 15 cm dia,150cm long,75cm above the ground and 75cm below the ground, with 4-12mm Tor steel main steel and 6mm MS stirrups at 30cm c/c tied in position with annealed black wire, cement concrete proportin 1:2:4 with broken stone aggregate up to 20mm size including centering,moulding the top.curing,painted black and white alternately in 23cm strips upto 0.75m from the top having reflective band 2 nos. of desired shade etc. as per design and direction complete. (ii) 30 cm dia with 6-12mmTor bar. |
| 28 | Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). (ii) 60 cm equilateral triangle |
| 29 | Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). (iii) 60 cm circular |
| 30 | Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). (v) 60cmm x 45 cm rectangular Please Enable Macros to View BoQ information |