| 1 | Supply, Installation, Testing & Commissioning of energy efficient LED outdoor luminaires suitable for street.perimeter lighting, shall be supplied alongwith necessary accessories, BIS certified potted driver & required fixing/installation hardware, metallic powder coated/G.I. mounting bracket. Specifications to be read in conjuction with detailed description of item and as shall be intalled as per directions from Engineer-in-charge. Note: 1. The design of illumination shall be done by OEM of luminaire @ avg. 15 Lux for the boundary wall/fencing area & same shall be submitted for approval. 2. The performance (Electrical & mechanical) of the luminaires shall be WARRANTEED for a period of minimum 5 Years from the date of commissioning. 3. Additional Security deposit amount @ 10% of total value of this item shall be withheld by the department for a period of 5 years from the date of completion of work.4. The technical datasheet along with LM-79, LM-80 & LED driver reports issued from NABL accredited lab for all the luminaires shall be submitted for approval. |
| 2 | LED street light luminaire: The specifications/desired parameters are as follows: Type of installation: Pole arm mountableHousing material : High pressure aluminium die cast housing , glass coverNominal Lumen output & overall lumen efficacy: 6000 lumen, >130 lumen/watt, Correlated Colour Tempreture(CCT): 4000/5700K, pf ≥ 0.95 (min),CoIor Rendering Index(CRI) ≥ 70, IP: 66, IK: 08, Surge protection level ≥ 4 kV internal, ≥ 10 kV external, THD ≤ 10 % Beam angle ≥ 120°, Life class: L70B50 @ 50 K hrs or better. |
| 3 | LED Street light luminaire: The specifications/desired parameters are as follows: Type of installation: Pole arm mountableHousing material : High pressure aluminium die cast housing , glass coverNominal Lumen output & overall lumen efficacy: 9000 lumen, >130 lumen/watt, Correlated Colour Tempreture(CCT): 4000/5700K, pf ≥ 0.95 (min),CoIor Rendering Index(CRI) ≥ 70, IP: 66, IK: 10, Surge protection level ≥ 4 kV internal, ≥ 10 kV external, THD ≤ 10 % Beam angle ≥ 120°, Life class: L70B50 @ 50 K hrs or better. |
| 4 | LED street light luminaire: The specifications/desired parameters are as follows: Type of installation: Street light pole arm mountableHousing material : High pressure aluminium die cast housing , glass coverNominal Lumen output & overall lumen efficacy: 16000 lumen, >130 lumen/watt, Correlated Colour Tempreture(CCT): 4000/5700K, pf ≥ 0.95 (min),CoIor Rendering Index(CRI) ≥ 70, IP: 66, IK: 10, Surge protection level ≥ 4 kV internal, ≥ 10 kV external, THD ≤ 10 % Beam angle ≥ 120°, Life class: L70B50 @ 50 K hrs or better. |
| 5 | LEDTop Post luminaire: The specifications/desired parameters are as follows: Type of installation: Pole top postMounting: on existing poleHousing material : High pressure aluminium die cast housing , poly carbonate optical coverNominal Lumen output & overall lumen efficacy: 4500 lumen, >100 lumen/watt, Correlated Colour Tempreture(CCT): 4000/5700K, pf ≥ 0.95 (min),CoIor Rendering Index(CRI) ≥ 70, IP: 66, IK: 10, Surge protection level ≥ 4 kV internal,THD ≤ 10 % Symmentry: Asymmetrical, Life class: L70B50 @ 50 K hrs or better. |
| 6 | Retrofitting of conventional street light/top post with LED Top post luminaire on existing pole: The specifications/desired parameters are as follows: Type of installation: Pole top postMounting: on existing poleHousing material : High pressure aluminium die cast.Nominal Lumen output & overall lumen efficacy: 4500 lumen, >100 lumen/watt, Correlated Colour Tempreture(CCT): 4000/5700K, pf ≥ 0.95 (min),CoIor Rendering Index(CRI) ≥ 70, IP: 66, IK: 08, Surge protection level ≥ 4 kV internalTHD ≤ 10 % Symmentry: Asymmetrical, Life class: L70B50 @ 50 K hrs or better.Exsiting old luminare shall be removed and shifted to stores at RRCAT. |
| 7 | Supply, erection and installation of octagonal G.I. pole alongwith welded base plate and foundation bolts for street light: 5 metre length GI Octagonal Pole with overhang arm decorative bracket of following sizes with angle of tilt as per the Luminaire OEM design. The G.I. structure shall be continuously tapered having 3 mm thickness throughout the length of the pole. The bottom diameter shall be 130 mm and top diameter shall be 70 mm. The base plate size shall be 200x200x12 mm and 4 Nos. 16 mm diameter 600 mm long J type anchor bolts. The door for control gear and cable jointing shall be flush with pole external surface and shall provide easy access for electrical connections, earthing of pole shall be done with earth driven rod and GI wire/strip as per detailed specification. The scope includes excavation in groud work, supply of material and preparation of RCC foundation, min two (02) 50 mm dia HDPE pipes inserted for cable entries, 6A, SP (Ics ≥ 10 kA) MCB, heavy duty 16A-4 pole connector for cable end terminations and 3Core x1.5 sqmm FR PVC insulated flexible cables for inside connection are included in the scope of this item. Detailed description of item and direction of engineer in charge shall be referred. |
| 8 | GI Octagonal pole with 1metre double/differential arm decorative Bracket (single/separate mounting) bracket & complete with foundation, base plate, anchor bolts & all required accessories & G.I. hardware. |
| 9 | GI Octagonal pole with 1 metre single arm decorative bracket & complete with foundation, base plate, anchor bolts & all required accessories & hardware |
| 10 | Design, Fabrication, Supply, Installation, Testing & Commissioning of 4 meter Height (from FGL) Street Light Pole (50 mm dia GI pipe) for mounting of top post LED outdoor light Luminaire as per our tender specifications & tender drawing. The design & construction of pole mounting / foundation, Powder coated MS pole box & other required material & hardware for installation of the Street Light Pole are also included in the scope of this item. |
| 11 | Design, Fabrication, Supply, Installation, Testing & Commissioning of floor/wall/MS stand/trench mounted, MS fabricated and powder coated Power Distribution Board Panel as per following brief details & our tender specifications: Incomer: 63A FP MCCB (Ics≥36kA) with microprocessor based trip release for over load, short circuit short time delay & instantaneous both & earth fault protection(LSIG) having independent adjustable current & time settings for all protections- 01 No. Outgoings: 63A, FP, AC-3 type Contactor- 01 No. Outdoor type light depending sensor based switch (Nature Switch) with multi choice control options- 02 Nos. Auto/Manual selector switch- 01 No. ON/OFF/Trip Indication Lamps backed up with control MCBs for MCCB & Contactor.Note: MCCB shall be independant for use without any external accesory/power supply for undercurrent tripping allowed. |
| 12 | Supply and Installation of Hot Dipped Galvanised Iron (GI) earthing conductor (50x6/32x6/25x3strip/wire) including required hardware for installation |
| 13 | Supply, fabricating, cutting, erecting, and fixing in position structural steel works of any shape using ISMBs, Joists, channels, angles, flats, Tees etc., at all levels including welding, painting with a primary coat of steel primer & 2 coat of black paint and transportation etc. complete as per specifications and as directed by Engineer-in-Charge. |
| 14 | Supply, Installation, Testing & Commissioning(SITC) of 1100 V grade, 4 core 10 sq. mm stranded Aluminium conductor, XLPE insulated, Extruded PVC inner sheath, FR PVC outer sheathed & G.I. round armoured power cables as per IS: 7098 part-1. All required material (Power cable, manual excavation for trench in ground (brick, sand, pipe etc), transportation, material handling, manpower, fixing material & hardware, use of testing tools & personal safety equipment etc. required for cable installation, testing & commissioning are included in this item. |
| 15 | In ground |
| 16 | In/on/at existing: hume pipe/wall/cable tray/MS support etc |
| 17 | Only Installation, Testing & Commissioning(ITC) of 1100 V, 4 core 25/16 sq. mm Copper/Aluminium armoured/unarmoured Aluminium/copper conductor, XLPE/PVC insulated, power cable in/on/at Hume pipe/wall/cable tray/MS support etc , to be installed as per IS: 1255. All required fixing material & hardware for cable installation, testing & commissioning are included in this item |
| 18 | Supply, Installation, Testing & commissioning of End termination of Aluminium, armoured power cables of following sizes with double compression gland |
| 19 | 4 core 25/16 sq. mm, Aluminium conductor G.I. armoured power cable |
| 20 | 4 core 10 sq. mm Aluminium conductor G.I. armoured power cable |
| 21 | Supply & Installation of Cable Route Marker made out of ready made \\"LT Cable\\" marking plate fixed on ISA 50x50x5 mm/ 50 mm dia Class-B MS pipe with masonry work of 200x200x200 mm. |
| 22 | Supply, installation of 50 mm dia HDPE Pipe of 4 kg. pressure on wall / trench by supply and fixing of MS clamps and other hardware as required at site. |
| 23 | Supplying, lowering, laying, RCC spun pipes (Class NP2) of IS:458 with necessary collars, laid to correct grade and level sat all depths including cutting to length, jointing with hemp yarn and C.M. 1:1, caulking the joints and finishing, curing, testing etc. complete |
| 24 | 300 mm dia |
| 25 | 150 mm dia |
| 26 | Excavation in all type of soil for foundation/trenches for cable/Earthing route etc. |
| 27 | Road/RCC Path cutting: Bituminous/WBM/PCC path cutting for laying power cable/Hume pipes/ GI pipes etc as per site requirement including disposal of unserviceable materials within 500 metres area etc. |
| 28 | Repairing of road cutting of all types as per site requirements Please Enable Macros to View BoQ information |