| 1 | Earthwork in excavation of foundation trenches in hard soil including dressing of sides and leveling the bed up to the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering and dewatering (if required) with cost of labour, hire & running charges of water pumps sundries & T&P required for the work complete as directed by the Engineer-in-charge. {Rate of excavation=(Ordinary soil+Hard soil+Stony earth)/3} |
| 2 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. ` |
| 3 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. In depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. (Measurement will be taken on finished compacted section only). |
| 4 | Construction of granular sub-base by providing sub-base with morum spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 5 | P.C.C (1:4:8) with 40 mm size Crosser broken hard granite metal with cost of all labour & materials. |
| 6 | R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusherbroken) stone chips includinghoisting and laying |
| 7 | RCC with C/S for column base |
| 8 | RCC with C/S for column |
| 9 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer-In-Charge. |
| 10 | Supply & laying of 40 mm HDPE pipe for laying of cable including cost of materials, labour, T&P and Transportation as per direction of Engineer-in -charge. |
| 11 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. IS 5758:1984 complete |
| 12 | Painting two coats with Synthetic Enamel paint to all surface |
| 13 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete SP - 63:2018. in all respect conforming to IRC |
| 14 | Brick masonary using Flyash bricks in CM (1:6) in Super-Structure with cost of all labour and materials, etc complete.(230x110x80) |
| 15 | 16mm plaster in CM(1:6) |
| 16 | 12mm plaster in CM(1:6) |
| 17 | 2.5 cm thick A.S Flooring in C.C (1:2:4) including punning using 12 mm size C.B hard granite chips with cost of all labour & other materials etc complete. |
| 18 | Supplying ,Providing & applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, including all material labour complete at all floors and all heights. (External Surface)at all elevations as per the direction of Engineer-In-Charge . |
| 19 | MS Steel work in built up (round, square or rectangular hollow tubes) trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 20 | GCI Sheet - For Roofing |
| 21 | Clearing & grubbing road land including uprooting rank vegetation, grass , bushes..etc all complete. |
| 22 | Dismentalling of existing structures like culverts, bridges, retaining wall.. Etc all complete. |
| 23 | brick wall |
| 24 | Loading and carriage by mechanical means.. Etc all complete |
| 25 | Rigid smooth centering and shuttering for RCC works. |
| 26 | Point wiring in PVC conduit with Modular type Switch: Recessed/Surface wiring to Light Point / Fan Point / Exhaust Fan Point / Call Bell point with 1.5 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non- metallic PVC flexible conduit with 5 Amp. 250 Volt. modular type Switch of ISI marked and ceiling rose of ISI marked mounted on Modular box with cover of suitable size , 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard ) |
| 27 | Group - B |
| 28 | Group - C |
| 29 | Supplying and fixing of suitable modular box deep (nominal size) on surface or in recess with suitable size of modular cover in front including providing and fixing 3pin 5 / 6 amps socket outlet and 5 / 6 amps modular type switch, connection, painting etc as required. as per the direction of the Engineer-in-Charge. (make: Havells/Finolex/Anchor) |
| 30 | Supplying and fixing of suitable modular box deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3pin 15 / 16 amps socket outlet and 15 / 16 amps modular type switch, connection, painting etc as required. as per the direction of the Engineer-in-Charge. (make: Havells/Finolex/Anchor) |
| 31 | Circuit / Sub-Main wiring in PVC conduit (2 x 1.5sq.mm + 1 x 1.5sq.mm): Recessed/ Surface wiring to Sub-Main in 2 x 1.5 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694 / 1990 with 20 mm dia non- metallic heavy duty PVC flexible conduit 1.6mm along with 1 x 1.5sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required as per the direction of the Engineer-in-Charge. (Make of wire - Finolex / L&T / Anchor / Havels / V Guard) (SR Sl. No.1.8.1) |
| 32 | Circuit / Sub-Main wiring in PVC conduit (2 x 2.5sq.mm + 1 x 1.5sq.mm): Recessed wiring to Sub-Main in 2 x 2.5 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694 / 1990 with 20 mm dia non- metallic heavy duty PVC flexible conduit 1.6mm along with 1 x 1.5sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required as per the direction of the Engineer-in-Charge. (Make of wire - Finolex / L&T / Anchor / Havels / V Guard) (SR Sl. No.1.8.2) |
| 33 | Circuit / Sub-Main wiring in PVC conduit (2 x 4sq.mm + 1 x 1.5sq.mm): Recessed/Surface wiring to Sub-Main in 2 x 1.5 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694 / 1990 with 20 mm dia non- metallic heavy duty PVC flexible conduit 1.6mm along with 1 x 1.5sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required as per the direction of the Engineer-in-Charge. (Make of wire - Finolex / L&T / Anchor / Havels / V Guard) (SR Sl. No.1.8.1) |
| 34 | Circuit / Sub-Main wiring in PVC conduit (2 x 6sq.mm + 1 x 2.5sq.mm): Recessed/Surface wiring to Sub-Main in 2 x 6 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694 / 1990 with 25 mm dia non- metallic heavy duty PVC flexible conduit 1.6mm along with 1 x 2.5sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required as per the direction of the Engineer-in-Charge. (Make of wire - Finolex / L&T / Anchor / Havels / V Guard) (SR Sl. No.1.8.4) |
| 35 | S/F SP MCB DB: Supply and fixing of the following way single pole and neutral, sheet steel, MCB dustribution board 250 Volts on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dib bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing as required as per the direction of the Engineer-in-Charge. (But without MCB/RCCB/Isolator) (SR Sl. No.2.3) |
| 36 | B) 4 way, Single door (SR Sl. No. 2.3.2) |
| 37 | S/F \\"B\\" SERIES, SP MCB : Supply and fixing of 5 Amp to 32 Amp rating 240 Volts \\"B\\" searies Miniature Circuit Braacker (MCB) for lighting and otherr loads of the following poles in the existing MCB DB ISI marked comple with connections, testing and commissioning etc. as required as per the direction of the Engineer-in-Charge. (SR Sl. No.2.6). |
| 38 | A) Single Pole (SP) (SR Sl. No.2.6.1) |
| 39 | Supply and fixing of following rating two pole [ phase and neutral) 230 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required as per the direction of the Engineer-in-charge |
| 40 | G.I. earth pipe electrode with salt and charcoals: Earthing with G.I. earth pipe 3 Mtrs. Long 40mm dia of ISI marked including accessories and providing masonary enclosure with cover plant having locking arrangement and watering pipe etc. as per the direction of the Engineer-in-Charge. (with Charcoal and salt) (SR Sl. No. 3.2) |
| 41 | S/L No.6 SWG G.I. Wire in ground: Supply and laying of No.6 SWG G.I wire ISI Marked at 0.5 meter below ground level for conductor eath electrode including soldering etc. as required as per the direction of the Engineer-in-Charge. (SR Sl. No. 3.8) (For 2 no. Earthing) |
| 42 | Supply and stringing of 10 Sq.mm twin core PVC insulated PVC sheathed aluminum wire support with No.10 G.I. wire and binding wire including cost of materials, labour, T&P and transportation etc. complete as per direction of the Engineer-in-Charge. |
| 43 | Supply and fixing of lighting Fixtures of 120 Watt. LED flood light with accessories and 4 nos Anchor Bolt and IP 66 protection mounting on the pole with angle frame having following specification as per the direction of the Engineer-in-Charge:(i) LED :LM80 certified high power LED,ii) Lens: Suitabale secondary lens for better light distribution,iii)Gear: Integral,Electronics constant current driver of min 85% efficiency,iv Internal wiring: Teflon insulated, Cu conductor,v)Ingress protection: IP 66, vi) Lumen Maintenance: 50,000 Hrs@ L70,viii) Operating temperature: -10°C to 50°C,Lumen 10800 lm, CCT:5700K,CRI:>70 (Make : BAJAJ / CROMPTON / SURYA / PHILIPS / HPL) |
| 44 | SITC of Main Switches: Supply, installation, Testing and Commissioning of Main Switches IS- 13940 Part-III / 1983) of following capacity on existing surface / wall mounting and complete with HRC Fuse lionks, interconnections, earthing, etc. as required as per the direction of the Engineer-in-Charge. (Make- SEIMENS/ HPL / L&T / Anchor / Havels /C&S/ RK)(SR Sl. No.2.15) |
| 45 | A) 63 Amp D.P Main Switches. (SR Sl No.2.15.1) |
| 46 | Supply and fixing of (1400mm) High Speed energy efficient 53 Watt. Ceiling Fan complete with down rod without regulator etc. complete with transportatiion, T&P and labour charges as per direction of the Engineer-in-Charge.(Havells, Bajaj, Usha, Crompton) |
| 47 | Supply and fixing of Mini Fan Regulator Rotary Step for above ceiling Fan etc. complete with transportatiion, T&P and labour charges as per direction of the Engineer-in-Charge.(Make: Anchor / Havels / V Guard) |
| 48 | Supply and fixing of Baton integrated 20 Watt. LED Batten Tube Light intergral sleek extrudedmpolycabonate LED Channel with white acrylic cover etc. complete with transportation, T&P and labour chares as per direction of the Engineer-in-Charge. (MAKE: BAJAJ / HAVELLS / CROMPTON / PHILLIPS) |
| 49 | Supply, installation and commissioning of 1600VA 12 volt heavy duty inverter (UPS) including cost of materials, labour, T&P and Transportation etc. complete as per direction of the Engineer-in-charge. |
| 50 | Supply and Fixing of fully charged 150 Ah exide red tall Tubular Battery suitable for 2350 VA 12 Volt Heavy Duty Inverter(UPS) including cost of materials, labour, T&P and Transportation etc. complete as per direction of the Engineer-in-charge. |
| 51 | Supply and Fixing of Single Battery trolly(Plastic Container) suitable for 1550 VA 12 Volt Heavy Duty Inverter(UPS) including cost of materials, labour, T&P and Transportation etc. complete as per direction of the Engineer-in-charge. |
| 52 | Supply and stringing of 1.5 Sq.mm. PVC insulated, PVC shealthed multistrand single core copper wire to running the each point for Inverter as per direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |