| 1 | Earthwork in excavation of foundation trenches in hard of soil including dressing of sides and leveling the bed up to the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering and dewatering (if required) with cost of labour, hire & running charges of water pumps sundries & T&P required for the work complete as directed by the Engineer-in-charge. {Rate of excavation=(Ordinary soil+Hard soil+Stony earth)/3}) |
| 2 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. ` |
| 3 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. In depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. (Measurement will be taken on finished compacted section only). |
| 4 | P.C.C (1:4:8) with 40 mm size Crosser broken hard granite metal with cost of all labour & materials. |
| 5 | R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and layingDrain |
| 6 | Rcc with C/S Column base |
| 7 | Rcc with C/S plingth beam |
| 8 | Rcc with C/S Column & beam |
| 9 | Rcc with C/S roof slab |
| 10 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. |
| 11 | Construction of granular sub-base with moroum providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 12 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete SP - 63:2018. in all respect conforming to IRC |
| 13 | Brick masonary using Flyash bricks in CM (1:6) in F&P with cost of all labour and materials, etc complete.(230x110x80) |
| 14 | Brick masonary using Flyash bricks in CM (1:6) in Super-Structure with cost of all labour and materials, etc complete.(230x110x80) |
| 15 | 12mm thick Cement Plaster (1:6) for brickwork including cost conveyance and royality etc complete. (inside) |
| 16 | 1 St floor |
| 17 | Providing weather coat over a coat coat with water bound Cement primer of approved brand and manufacture on plaster surface at all elevations including all material & labour complete at all floors and all heights as per the direction of Engineer-In-Charge . |
| 18 | 16 mm thick cement plaster in (1:6) with cost of all labour & materials. |
| 19 | Supplying ,Providing & Applying plastic emulsion paint over a coat of water bound cement primer with all cost conveyane etc complete. |
| 20 | Supplying M.S. Grill, Gate made out of angle,flat and square bar including cost of transportation, taxes, painting Two coats enamel paint, one coat of priming etc.all complete. As per approved design and Direction of Engineer - In- Charge. (per Kg.) |
| 21 | Provinf enamel paint 2 coat over a coat of red oxide Primer over iron work including all coat conveyance taxes etc complete. |
| 22 | Dismantling and removing doors, windows, and ventilators including removal of frames,hinges,fastenings and stacking the usefull materials for reuse and removing the debries within 50mtr lead. (data for 2.6sqm.) |
| 23 | Providing, fitting and fixing Vitrified tile in floor of size 600x600 mm of approved make conforming to IS: 13755 laid on 20 mm thick cement mortar 1:4 (1 cement: 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-In-Charge (for New work only) |
| 24 | Supplying, fitting & fixing of 30cm x 20cm/20cm x 20cm special plain/printed series Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 in dadoes, skirting and risers of steps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 25 | Fixing Granite Stone 20mm thick. (above 0.40 sqm) in floors treads or steps and landing Fixing tiles in floors treads or steps and landing (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of precast tiles per 1 sqm |
| 26 | Supplying, fitting & fixing of Chequered tiles in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge |
| 27 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips. On new work per 1 sqm. |
| 28 | Providing & fixing UPVC Door Shutter with frame with/without 6mm thick glaass with all necessary fitting & fixture of approved hardware and all materials complete as per direction of the Engineer-In-Chareg. |
| 29 | Supplying, fitting, fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C & stainless square pipe bracing of 32mm x 32mm x 2mm in 3 rows in stair case as per approved design & specification, buffing, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required etc. complete. |
| 30 | 2.5 cm thick A.S Flooring in C.C (1:2:4) including punning using 12 mm size C.B hard granite chips with cost of all labour & other materials etc complete. |
| 31 | Providing supplying fitting and fixing of 3 seater Rcc concrete benches having back rest and arm rest and painted with enamel paint 2 coat over a coat of water bound cement primer including all cost conveyance etc complete. |
| 32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 33 | 15 mm nominal outer dia .Pipes. |
| 34 | 20 mm nominal outer dia .Pipes. |
| 35 | 25 mm nominal outer dia .Pipes. |
| 36 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 37 | 32 mm nominal bore |
| 38 | 40 mm nominal bore |
| 39 | 50 mm nominal bore |
| 40 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 41 | 15mm nominal Bor |
| 42 | 20 mm nominal bor |
| 43 | 25 mm nominal bor |
| 44 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : |
| 45 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 46 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 48 | 75 mm diameter Type -A |
| 49 | 110 mm diameter Type -A |
| 50 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 51 | Fixing wash Down water closet , (European type W.C Pan) confirming to IS 2556: Part 8 -2004 ,to the ffloor with wooden plug and chromium plated screws joining the trap with ssoiil pipe in c.m(1:1) etc all complete as per specification. |
| 52 | W.C. pan with ISI marked white solid plastic seat and lid |
| 53 | Fixing Flat back Small urinal confirming to IS 2556: Part 6 -1996 including connecting the urinal of size 31.5x26.5x44 cm sizes respectively with wash pipe by means of white lead mixed with chopped hemp etc all complete as per specifications. |
| 54 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 55 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 56 | wash basin with hole (550x400) |
| 57 | C I bracket for wash basin |
| 58 | fixing of pedestal for wash basin |
| 59 | Providing and fixing CP Brass 32 mm size bottle trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 60 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 61 | Semi rigid pipe 40 mm dia. |
| 62 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 63 | 15 mm nominal - bore |
| 64 | Installation testing and commissioning of Health faucet of approved make & model. |
| 65 | Providing and fixing in position 75 mm N.B.UPVC. Nahani traps of self cleaning design including 100 mm dia UPVC grating, joining, embedding in concrete etc. complete rate to include making of opening in floor, marble / tiles, for fixing grating.(Inside the toilets & Kitchens) |
| 66 | Providing & fixing in position 80mm NB \\"P\\" type trap of self cleaning type (inlet to \\"P\\" trap to be 100mm dia) including brass 125mm dia CP grating, lead jointing embeding in concrete etc. all complete. |
| 67 | Providing and fixing, jointing of uPVC waste pipe (IS: 4985 6Kgf/cm2)including all fittings (Plain or door) e.g. bends, junction, cowls, offsets, access pieces,jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good where required. |
| 68 | 32 mm NB |
| 69 | Providing & fixing heavy forged brass ( chrome plated ) tested ISI marked Ball valves as per ( IS:554 /B5:21/ISO : 7 full bore design ) of approved quality for 15 mm to 40 mm and Wafer type butterfly valve of pressure rating PN10 confirming to BS 5155 for 50 mm and above. |
| 70 | 32 mm |
| 71 | Providing and fixing of SWR PVC vent / waste water / waste water & soil pipes, Type 'B' conforming to I.S. - 13592, and fittings confirming to I.S. 14735/99 cut to required lengths including all necessary fittings and specials such as as 45 or 90 deg. bends, Tee's, Y's, access pipe with solvent cement jointing. Setting the pipes in cement concrete M-15 as per specifications after testing of pipes. |
| 72 | 110 MM diameter Type-C |
| 73 | Recessed wiring to light point/Fan Point/Exhaust Fan Point/ Call Bell point with 1.5 Sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 6Amp, 250V Modular switch ISI marked and ceiling rose ISI marked mounted on Metal Box having front Modular cover of suitable size, Metal box with 1.5 Sqmm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Finolex/L&T/Anchor/Havells/V-Guard/KEI/RHINO/C&S) |
| 74 | Group-A-L.P F.P- C.B.P- |
| 75 | Group-B-L.P F.P- C.B.P- |
| 76 | 6 Amp Switch (Modular Type) |
| 77 | 6 Amp Socket |
| 78 | 16 Amp Switch |
| 79 | 16 Amp Socket |
| 80 | Ceiling Rose |
| 81 | Exhaust Fan 9\\" size |
| 82 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6pin 6Amp & 16Amp socket outletand 16Amp Modular switches connection (make-Anchor/ Legrand /Roma) |
| 83 | S/F of 12watt Square Surface down light LED fitting (Make- Havels/Philips/Bajaj/Crompton/Helonix) ( GT- 04, LT- 04, PHT-02) |
| 84 | S/F of 32 AMP 25KA MCCB' of Hager Make with both side connections with all complete. Please Enable Macros to View BoQ information |