| 1 | Earthwork in excavation of all kinds of soil and deposited the excavated earth within a lead of 5M by Mechanical means including laoding and unloading from truck with all cost of labour T&P etc.reqd. for the work complete as per direction of Engineer-in-charge. |
| 2 | Supplying,filling foundation and plinth with excavated earth well watered and rammed including all cost of materials and labour T&P etc. comple as directed by Engineer-in-charge. |
| 3 | Filling foundation with sand well watered and rammed with appropriate rammer /Mechanical compactor and top surface dressed and levelled to proper gradient including all cost of materials and labour T&P etc. comple as directed by Engineer-in-charge. |
| 4 | Providing Plain cement concrete (1:3:6) by using 4cm size BHG(C.B) metal of appd.quality from appd.quarry including hoisting,lowering and laying concrete in layers to the reqd.levels ramming watering, curing etc. complete including cost,conveyance,royalties and taxes of all materials with all labour T&P reqd. for the work etc.complete in all respect and as per direction of Engineer-in-charge. |
| 5 | Providing Plain cement concrete (1:2:4) by using12mm size BHG(C.B) Chips of appd.quality from appd.quarry including hoisting,lowering and laying concrete in layers to the reqd.levels ramming watering, curing etc. complete including cost,conveyance,royalties and taxes of all materials with all labour T&P reqd. for the work etc.complete in all respect and as per direction of Engineer-in-charge. |
| 6 | RCC work of Prop (M-20) using 20mm and down graded BHG(C.B) stone of appd.quality from appd. Quarry including hoisting,lowering,laying and compacting concrete,watering and curing centering,shuttering and finishing the exposed surface smooth with cost,conveyance,royalties and taxes including all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge. (A)Footing |
| 7 | (B) Plinth Beam |
| 8 | (C ) Column / Beam |
| 9 | (D ) Lintel |
| 10 | (E ) Sunshades Ground Floor |
| 11 | ( C) Roof Slab,lamdings & Chajjas Ground Floor |
| 12 | Cutting straightening of steel HYSD (Fe-415) conforming to (IS-1786) with bending, binding, cranking, hooking, welding or joining if necessary & tying the grills and placing in position as required for the Rod work in all floors and & for providing fan hooks hosting lowering & laying steels including cost conveyance taxes & royalties of alol materials and binding wires of 18 to 20 gauge & cost of all labour T&P required for the work etc. complete in all respect as per the direction of Engineer in charges (payment will be made on weight of MS rod or tersteel only basing on the co-efficient of MS rod or for steel bars approved by SAIL/TATA/competent authority and (No separate payment will be made towards the cost of binding wires over lapping, wastage coupling welded, joints,spacer bars, chairs stays,hangers and annealed steel wire o9r other methods for binding and placing etc. complete as per the direction of Engineer-in-charge. |
| 13 | 20mm thick Cement plaster in C.M(1:4) as grading plaster including watering, curing conveyance, royality & all taxes of materials & labour with T&P T&P required for the work with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge. |
| 14 | Fly Ash brick masonary in C.M(1:6)using bricks of size 25cmx12cmx8cm having crushing strength 75kg/cm2 after immersing the bricks for six hours in water before use in Foundation and plinth with all necessary projections, cutting,moulding,corebelling, champering, watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge. |
| 15 | Fly Ash brick masonary in C.M(1:6)using bricks of size 25cmx12cmx8cm having crushing strength 75kg/cm2 after immersing the bricks for six hours in water before use in Superstructure with all necessary projections, cutting,moulding,corebelling, champering, watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge. |
| 16 | 16mm thick Cement plaster in C.M(1:6)over brick walls after rackingout joint including watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge. |
| 17 | 12mm thick Cement plaster in C.M(1:6)over brick walls after rackingout joint including watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge. |
| 18 | 6 mm thick Cement plaster in C.M(1:4) as ceiling plaster after rackingout joint including watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge. |
| 19 | Providing,fitting and fixing Vetrified floor tiles in floors,treads and steps over 20mm thick bed of C.M(1:4) jointed with application of Polymer modified cement based water resistant adhesive mixed with pigment to match the shades of tiles including all cost of materials and labour T&P etc. reqd. for the work complete as per direction of Engineer-in-charge. |
| 20 | Providing,fitting and fixing Vetrified tiles in Dados,riser and sterps over 12mm thick bed of C.M(1:3) jointed with application of Polymer modified cement based water resistant adhesive mixed with pigment to match the shades of tiles including all cost of materials and labour T&P etc. reqd. for the work complete as per direction of Engineer-in-charge. |
| 21 | Providing,fitting and fixing (Vetrified Industrial tiles) Floors trads or steps and laniing on 20 mm thick bed of C.M(1:4) jointed with application of Polymer modified cement based water resistant adhesive mixed with pigment to match the shades of tiles including all cost of materials and labour T&P etc. reqd. for the work complete as per direction of Engineer-in-charge. |
| 22 | Supplying fitting and fixing of M.S.Grills, Grill gate, M.S.Gates, M.S.door, M.S.Angle , M.S.Shutter with Choukaaths ,Collapsible gates with top and bottom rails,steeel windows critical frames for windows ,staircase and parapet railing made out of M.S.Square bar / flat including .as per approved drawing and design with cost of all materials and labour, taxes, labour cess, T&P sundries etc.complete in all respect as per specification and direction of the Engineer-in-charge. |
| 23 | Supplying and fitting, fixing of Un-plasticised polyviny) chioride (UPVC) (FENESTA/ NCL/VEKA LTD) Casement Door-60-Series duly manufactured using (UPVC reinforced profiles of 60mmx55mmx2.5mm for outer frames, 102mmx60mm x 2.25mm for casement door sash profile and 74mmx60mmx2.5mm mution profile capable of mounting single glazing system, structurally reinforced with not dip galvanised up t0 50 microns of minimum thickness of 2.0 mm prefabricated and welded through fushion welding the door sash shall be fitted with 12mm thick WPC board of arren, |
| 24 | Supplying and fitting, fixing of Un-plasticised polyviny) chioride (UPVC) (FENESTA/ NCL/VEKA LTD) Three silding window -60-Series duly manufactured using (UPVC reinforced profiles of , 108mmx45mm x2.5mm of outer frames and window sash of and window 2.25mm for casement door sash profile and 39mm x 58mm x 2.5mm capable of mounting single glazing system, structurally reinforced with not dip galvanised up t0 50 microns of minimum thickness of 2.0 mm prefabricated and welded through fushion welding the door sash shall be fitted with 12mm thick WPC board of arren, |
| 25 | Painting two coats to wall surface with approved plastic emulsion paint of appd.shade including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge. |
| 26 | Finishing wall surface with Acrylic wall putty (Water based) of appd.make and finished smooth and even surface to receive painting including cost of scaffolding stagging charges with all cost of materials and labour T&P etc.complete as per direction of the Engineer-in-charge. |
| 27 | Painting two coats with enamel paint of appd. shade Door/window over wood / Iron work over a coat of primer including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge. |
| 28 | Finishing out side wall surface with Weather Coat (I.S.I )two coats with any approved shade over coat of primong including cost of sil materials and labour T&P etc. complete as per direction of Engineer-in-Charge. |
| 29 | Providing , fitting & fixing of fales ceilling with Aluminium anodised .'T' Section No.3215 with 2'-0\\" c/c L. Section No.1708m up to 15 micron on 4 walls to be fixed by means of steel scrrew and P.V.C plug and the Aluminium grid 2'-0\\" 2'-0\\" with prelaminated particie suspended from celling etc. complete. |
| 30 | EI Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Raw power switchboard shall be separate from emergency switch board.Each light point should have provision for ceiling rose and angle holder point. Light Point GROUP-A |
| 31 | Light Point GROUP-B |
| 32 | Light Point GROUP-C |
| 33 | Fan Point GROUP-B |
| 34 | Fan Point GROUP-C |
| 35 | Call Bell Point GROUP-C |
| 36 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 37 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 38 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 39 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 40 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 41 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 42 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit . (2X6+1X1.5) |
| 43 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 44 | S/F of Computer Board Consisting 3 Nos of 5Amp 5Pin 240V F.T. socket and Switch ISI marked on M.S Board with all connection complete in all respect as per direction of Engineer in charge -(Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) ) |
| 45 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- legrand Myrius /Schneider(Zencelo)/Panasonic(Vision) , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 46 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision)) |
| 47 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. |
| 48 | Supplying and fixing of Energy efficient recessed mounted LED luminaire made up of CRCA powder coated housing, bottom opening clean room LED luminaire of 600 X 600 x 65 mm size with of 36 W and system lumens output not less than 3600 lumens , IP65 ,dust free & zero maintenance , anti glare high transmittance PMMA diffuser , operating volatge range 150-265 V, high performance potentiometric electronic driver for zero maintenance , 2.5 KV internal urge protection, L70 B 50: 50,000 hrs., CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,,IP 65 protection complete with all other accessories suitable for operation on 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2years. .Each CLEAN ROOM FITTING . |
| 49 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years |
| 50 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 51 | Supplying and fixing 63 amps rating, 240 volts, C series,10KA breaking capacity, double poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 52 | Supplying and fixing 32 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 53 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 54 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 55 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 56 | Supply Of 1.5Ton Split Type A.C Machine ( 5 Star ) ( Make- Carrier / Voltas/ Blue star ) |
| 57 | S/F of 5 KVA Voltage Stabiliser ( 130 Volt-300 Volt ) ( Make- V-Guard / Voltas/ ) |
| 58 | Installation Charges OF Split Type A.C Machine |
| 59 | S//F of Copper Colling Pipe with Insullation Packing and Fexible Copper Cable |
| 60 | S/F of Nylon Netted Drain Pipe With C Clamp |
| 61 | S/F of Powder Coated Wall Stand with Anchor Faster |
| 62 | Supply & Fixing Of 220 AH inverter Batterywith all Connection & acessoseries(Make-Luminous/exide/Microtek) |
| 63 | Supply & Fixing of 2.3 KW Inverter Machinewith all Connection & acessoseries (Make-Luminous/exide/Microtek) |
| 64 | Supply and installation of 63Amp ICDP main switches with MS board Please Enable Macros to View BoQ information |