| 1 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C ' class (Heavy) pipes conforming to IS 3589 / 1239 part-I for chilled water / Condensor water applications including cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger, vibration isolators and nuts bolts including cutting hole and chase in brick walls and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of desired shade (for condensor water only) complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). |
| 2 | 40 mm dia |
| 3 | 65 mm dia |
| 4 | 80 mm dia |
| 5 | 100 mm dia |
| 6 | 150 mm dia |
| 7 | 200 mm dia, 6.0 mm thick |
| 8 | 250 mm dia, 6.35 mm thick |
| 9 | 300 mm dia., 7.0 mm thick |
| 10 | Supplying & fixing of Thermal Insulation on Chilled Water Piping with Factory made Self Sleeve Tubes/ Pre cut Sheets of Class 'O' (FM Approved) Closed Cell Elastomeric Rubber Material, Glue, with 7 mil Glass Cloth with 3 coats of anti UV paint for thicknesses of 50/44/38/32 mm. Thermal Conductivity of this material is 0.035w/m.k. and having µ value ≥ 7000.0 - 65 mm dia : 32 mm thick , 80 -100 mm dia : 38 mm thick , 125 - 150 mm dia : 44 mm thick , 150 - 400 mm dia : 50 mm thick. (Up to 100mm dia Self Sleeve tubes &> 100 NB Pre cut sheets. etc. as required. |
| 11 | 40 mm dia |
| 12 | 65 mm dia |
| 13 | 80 mm dia |
| 14 | 100 mm dia |
| 15 | 150 mm dia |
| 16 | 200 mm dia |
| 17 | 250 mm dia |
| 18 | 300 mm dia |
| 19 | Supplying and Fixing of PN 1.6 Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. |
| 20 | 50 mm dia |
| 21 | 65 mm dia |
| 22 | 80 mm dia |
| 23 | 100 mm dia |
| 24 | 150 mm dia |
| 25 | 200 mm dia Gear Operated |
| 26 | Supplying and Fixing of PN 16 Brass/GM Ball valves with screwed end, SS Ball including teflon tape etc. as required. |
| 27 | 25 mm dia. |
| 28 | Supplying and Fixing of PN 16 Flanged Y strainer fabricated out of cast iron body, SS 304 strainer with perforated screen with 3 mm. dia holes in existing MS / GI pipe complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets etc as required of following sizes. |
| 29 | 65 mm dia |
| 30 | 80 mm dia |
| 31 | Supplying and Fixing of PN 16 Double regulating screwed balancing valve with nozzle and fabricated out of bronze, etc. as required of following sizes. |
| 32 | 40 mm |
| 33 | Supplying and Fixing of PN 16 Cast Iron Double regulating flanged balancing valve with nozzle and hand wheel complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. |
| 34 | 80 mm |
| 35 | 100 mm |
| 36 | 150 mm |
| 37 | 200 mm |
| 38 | 300 mm |
| 39 | Supplying & fixing of Thermal Insulation on Chilled Water line Butterfly valves / Sluice valves / NRV / PICV / Y strainer / Two Way Valve / Balancing valve with Class 'O' (FM Approved) Closed Cell Elastomeric Rubber Material with 7 mil Glass Cloth with 3 coats of anti UV paint for thicknesses of 32 mm. Thermal Conductivity of this material is 0.035w/m.k. and having µ value ≥ 7000. etc. as required. |
| 40 | 40 mm |
| 41 | 50 mm |
| 42 | 65 mm |
| 43 | 80 mm |
| 44 | 100 mm |
| 45 | 150 mm |
| 46 | 200 mm |
| 47 | 300 mm |
| 48 | Providing & Fixing of 26 SWG thick Aluminium sheet cladding on existing refrigerant copper pipe /insulated chiller pipe or any other surface with nut & bolts complete as required. |
| 49 | P & F of trap door for AHU / FCU's in existing false ceiling duly made from 12 mm thick laminated board, hinged with wooden frame of cheed wood size 50mm x 80mm, Frame suspended with MS strip 25 x 3 mm with anchor fastner min 8 supports from ceiling, Hinges, Locking arrangement etc as required. |
| 50 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. . |
| 51 | Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day ) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India |
| 52 | Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field ) |
| 53 | During the execution of the work labour shall be deployed for the removal and refixing of LAN/electrical fittings, fixtures and other electrical items at site. |
| 54 | Building Rubbish Stone Metal (Grit and ballast etc.) for 20 km away from site |
| 55 | The contractor is advised while shifting the debries in trolley from premises the trolley must be covered plastic terpal. |
| 56 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C ' class (Heavy) pipes conforming to IS 3589 / 1239 part-I for chilled water / Condensor water applications including cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger, vibration isolators and nuts bolts including cutting hole and chase in brick walls and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of desired shade (for condensor water only) complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). |
| 57 | 450 mm dia,10 mm thickness |
| 58 | Supplying & fixing of Thermal Insulation on Chilled Water Piping with Factory made Self Sleeve Tubes/ Pre cut Sheets of Class 'O' (FM Approved) Closed Cell Elastomeric Rubber Material, Glue, with 7 mil Glass Cloth with 3 coats of anti UV paint for thicknesses of 50/44/38/32 mm. Thermal Conductivity of this material is 0.035w/m.k. and having µ value ≥ 7000.0 - 65 mm dia : 32 mm thick , 80 -100 mm dia : 38 mm thick , 125 - 150 mm dia : 44 mm thick , 150 - 450 mm dia : 50 mm thick. (Up to 100mm dia Self Sleeve tubes &> 100 NB Pre cut sheets. etc. as required. |
| 59 | 450 mm dia |
| 60 | Supplying and Fixing of PN 1.6 Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. |
| 61 | 40 mm dia |
| 62 | 450 mm dia Gear Operated |
| 63 | Supplying & fixing of Thermal Insulation on Chilled Water line Butterfly valves / Sluice valves / NRV / PICV / Y strainer / Two Way Valve / Balancing valve with Class 'O' (FM Approved) Closed Cell Elastomeric Rubber Material with 7 mil Glass Cloth with 3 coats of anti UV paint for thicknesses of 32 mm. Thermal Conductivity of this material is 0.035w/m.k. and having µ value ≥ 7000. etc. as required. |
| 64 | 450 mm |
| 65 | SITC of following discharge and head, End suction chilled water/ Condensor water recirculation pumps complete with motor , base frame, vibration isolators, mechanical seal, Bronze/S.S. Impeller etc on buy back basis including dismentling of existing water pump set( capacity of 323 m3/h and 35.5 mtr head). The pump motor shall be suitable for 415 ± 10%, 50 cycles, 3 phase power supply, squirrel cage induction 1450 RPM TEFC, IE3 motor, class 'F' insulation, with vibration isolators on existing MS / RCC foundation. |
| 66 | Condensor water pump |
| 67 | Flow rate : 1400 USGPM, Head : 35.5 Mtr. |
| 68 | Buy back of existing heavy-duty MS “C” class old pipes of following sizes including labour charges for dismentling these pipes (alongwith associated valves) from the site in existing condition.The scope of work includes cutting and dismantling of the old pipeline, associated valves and removal of thermocol/aluminium cladding insulation using required scaffolding and safety arrangements. It also includes shifting the debries of sand, cement, plaster, thermocol insulation etc dismantled chilled water pipe from the basement area and dumping the same outside the RLA premises through tractor-trolley. the job includes dismantling of pipelines located inside false ceilings or on surface installations without causing any damage to existing structures, finishes or services.The dismantled material/scrap shall be retained by the contractor, and the corresponding buy-back value shall be deducted from the project cost. |
| 69 | 40 mm dia |
| 70 | 65 mm dia |
| 71 | 80 mm dia |
| 72 | 100 mm dia |
| 73 | 125 mm dia. |
| 74 | 150 mm dia |
| 75 | 200 mm dia, 6.0 mm thick |
| 76 | 250 mm dia, 6.35 mm thick |
| 77 | 300 mm dia., 7.0 mm thick |
| 78 | 450 mm dia, 7.94 mm thick Please Enable Macros to View BoQ information |