| 1 | Supply , Installation , testing and commissioning of standard 4.0 Mtr. High (above ground) hot dip galvanized (grading of galvenisation average 70 micron or better as per IS 2629 or equivalent) Octagonal pole, with stiffener, chain, allen bolt, foundation, single arm bracket, template, nut and bolts galvanized, factory finish base plate of size 200x200x12mm etc complete as required. The pole shall be made of 3mm thickness sheet with tolerance of +/- 5%. The column shall also be provided with flush door at the bottom with proper strengthening to the cutout of the door opening, a junction/loop box with heavy duty 3 phase , 32 Amp. connector with 16A DP MCB including all accessories complete as required derected by E/I.(Make -Valmont/Bajaj/Transrail) |
| 2 | S/Fixing of LED Street Light fitting having die cast Aluminium body and difuser with driver set suitable for 52 to 72 watt. Confirming to IP-66 and above protection. Complete in all respects. (PS No. 1422) Cat-AAA.(Make - Philips/Bajaj /Crompton /Havells/Wipro/LT) |
| 3 | Supply and Fixing of 16 Mtr High Mast pole of approved make with rising system, Hot dip galvanised inside & outside, having pole sheet thickness 3mm, top dia minimum 150 mm bottom dia miimum 360 mm base plate 32 m thick, suitable for wind velicity as per IS 875 part 3 & having no circumferential weld with accessories for High Mast such as heat frame suitable for 6 luminaries & its control gear boxes, 1.5 HP power tool motor, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufacturer drawing & site requirement along with foundation bolts, nuts, washer, Anchor plate etc. Complete in all respects as per direction and satisfaction to the Engineer-in-charge (PS No. 652) (Make - valmont/Bajaj/Transrail) |
| 4 | Supply and fixing of Factory wired integral LED Flood Light Luminaires with die cast Aluminium housing build with driver set suitable for 140 to 150 watt. Confirming to IP66 and above protection. Complete in all respects. (PS No. 1454) CAT-AAA . (Make - Philips/Bajaj /Crompton /Havells/Wipro/LT) |
| 5 | S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I.(AOR) |
| 6 | Supply of Steel Tubular Pole 11 M long designated 410-SP-56 . complete in all respects as per direction of E/I. .(UPERC P-30) |
| 7 | Errection of metallic pole of following length in cement concrete 1:3:6 ( 1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required above 10.0 mtr and upto 12 mtr (DSR 2018 I. n. 11.3.4) |
| 8 | Supply and erection of overhead line with ACSR Conductor (Dog & Raccoon) poles / service bracket including binding etc. complete in all respects. P.S. No. 627 |
| 9 | Painting of the electric pole with 2 Coats of aluminium paint over red oxide primer complete in all respects. P.S. No. 634 |
| 10 | Supplying of channel iron 75mmx40mmx6mm(7.14 Kg Per mtr) pole top bracket/cross arm for single 11 kV overhead line conductor complete with 50mmx6mm flat iron clamp, bolts, nuts and washer including drilling holes for insulator pins bolts and nuts etc, and painting with primer and finish paint as required (DSR-2018 item no. 13.2 pg.44) |
| 11 | S/E of straight MS Channel 50x100 mm. (9.2 Kg/M) 2.60 M long as per design with required clamps made of M.S. flat of size 50x6 mm. with nut & bolts etc. as per direction of E/I. .((UPERC P-30) |
| 12 | Supplying and erection of 11kV pin insulator complete with large steel head G.I. Pin, nuts & washer etc. as required (DSR-2018 item no. 13.10 pg.46) |
| 13 | Supplying and erection of 11kV Disc insulator for 11kV overhead line with galvanised inculator fitting, ball and socket type and complete with galvanised strain clamp, bolts, nuts & washer etc. as required (DSR-2018 item no. 13.11 pg.45) |
| 14 | S/F of 11 KV TPMO Relco/Rama/Azad make 9 Nos. insulator of Jai shree/BHEL/ Rama/ Rastriya make complete in all respects as per direction of E/I.(UPERC page no. 58) |
| 15 | S/E Testing & Commissioning of 63 KVA Al. wound outdoor type Transformer as per ISS. Complete in all respects Make : AZAD/P.M./Kanohar/LD Power/Paramix as per direction of E/I..(RESPO page no. 51) |
| 16 | Numbering of Pole with combination of yellow and black colour paint etc. complte in all respects as per direction of E/I. (AOR) |
| 17 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (KEI/Polycab/Havell's make) |
| 18 | (1) 16 Sq.mm. X4 2Core (PS No. 501) |
| 19 | 2) 50 sq mm 3.5 core (PS No 501) |
| 20 | S/F of cable Lug(socket) to the cable lead. Complete in all respects as per PS No. 504 |
| 21 | 1- 16 Sq.mm. |
| 22 | 2- 50 Sq.mm. |
| 23 | S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/ Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49 |
| 24 | S/Laying of 63 mm dia (OD 63 mm & ID 51 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/ Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49 |
| 25 | Supply and fixing of 40 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807D |
| 26 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) |
| 27 | Supply and burrying of 75 mm Dia 3 Mtrs. Long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/Mtr) in the ratio of 3:1:1 (marconite : cement : water) on M.S. Rod with hole (16 mm diameter X3 Mtrs ) will be vertically installed for earthing with 1Mtr G.I strip (25 mm X 2.5mm) connected with SS nut bolt. The earth electrode will be installed into the 100 mm pit up to 3000 mm depth. noraml soil will be used as backfill material. Make : As approved in U.P.P.W.D & C.P.R.I. Certified. (PS no 729(c) |
| 28 | Earth work in Excavation in by mechanical means (Hydraulic excavator) manual means over areas excaading 30 mtr in depth,1.50 mtr width as well as 10sqm on plan)including out and desposal of excavated earth ,load upto 50m and lift upto 1.5 m as directed by the Engineer incharge (AOR). |
| 29 | Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) (AOR) |
| 30 | Filling available excavated earth( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. (AOR). P- |
| 31 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required (AOR) |
| 32 | a) Bituminous Portion (AOR) (2265.0+18% gst) |
| 33 | b) Water Bound Macadam (AOR) (1400.0+18% gst) |
| 34 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/ submain wiring/ cable as required.DSR 2018 item no. 5.18. page no. 27 |
| 35 | Supplying and Laying of 6 sq. mm 2 core PVC Insulated Al. moued cable for street Light pole (as per RESPO-2018) annexure -3 pg. 17. Please Enable Macros to View BoQ information |