| 1 | Providing and making steel pole collar with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) of specified size and shape including form work, plastering if required, curing etc. as required. (Volume of pipe/pole not to be deducted)(Electrical DSR-14/Ite. No. 11.5 pg.37) |
| 2 | Dismantling of pole/Street Light standard /strut embedded in cement concrete foundation etc. as required (Electrical DSR-2018/item no. 12.42 P-46) |
| 3 | Errection of metallic pole of following length in cement concrete 1:3:6 ( 1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required above 10.0 mtr and upto 12 mtr (Electrical DSR 2018 I. n. 11.3.4 ) |
| 4 | S/E of overhead line with ACSR conductor on steel tubular poles incl. compression joint, laying stringing and binding etc. as PS No. 627 |
| 5 | Supplying and Laying of 6 sq. mm 2 core PVC Insulated Al. moued cable for street Light pole (as per RESPO-2018) annexure -3 pg. 17. |
| 6 | Supply and burrying of 75 mm Dia 3 Mtrs. Long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/Mtr) in the ratio of 3:1:1 (marconite : cement : water) on M.S. Rod with hole (16 mm diameter X3 Mtrs ) will be vertically installed for earthing with 1Mtr G.I strip (25 mm X 2.5mm) connected with SS nut bolt. The earth electrode will be installed into the 100 mm pit up to 3000 mm depth. noraml soil will be used as backfill material. Make : As approved in U.P.P.W.D & C.P.R.I. Certified. (PS no 729(c) P-144) |
| 7 | Supply and fixing of 40 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807F |
| 8 | Supply and making straight through joint with cast resin compound including ferrules and other joints material for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required |
| 9 | a) 3.5x70 sq. mm ((Electrical DSR-18/Ite. No. 9.3.20 pg.35) |
| 10 | b) 2x25 sq. mm ((Electrical DSR-18/Item. No. 9.3.2 pg.34) |
| 11 | c) 2x16 sq. mm ((Electrical DSR-18/Item. No. 9.3.2 pg.34) |
| 12 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Polycab, KEI, Havell's, make) |
| 13 | (a) 16 Sq.mm. x 2 Core (PS No. 501) |
| 14 | (b) 16 Sq.mm. x 4 Core (PS No. 501) |
| 15 | (c ) 50 Sq.mm. x 3.5 Core (PS No. 501) |
| 16 | S/F of Palm or Pin type copper tin plated cable socket (lugs) to the cable lead insulation with tape and making connections complete as per direction of E/I. P.S. No. 504 |
| 17 | a)- 16 sq. mm |
| 18 | b)- 35 sq. mm |
| 19 | c)- 50 sq. mm |
| 20 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m. The contractor has detect different utilities like sewer line, water supply line, electric cable, Telephone cable, Gas pipe line etc. using utility detecting machine before start of excavatiob and shall start excavation only after permission of Engineer in charge. All kind of soil. (136.0 + 18% GST) (AOR) |
| 21 | Filling available excavated earth( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. (AOR) |
| 22 | S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along wigh all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49 through Treanchless/manually |
| 23 | S/F of jointing of 185 sq. mm out door type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion Make : Raychem/ Denson/ Capseal as per direction of E/I. (UPERC P-28) |
| 24 | S/Making of Straight through joint suitable for 185 sqmm x 3 core 11KV XLPE cable as per ISS & Complete in all respects Make: Raychem, Denson, Cabseal. As per direction of E/I. (UPERC P-41) |
| 25 | Supply and fixing of XLPE insulated Aluminium unarmoured cable for working voltage for enerizing the distribution boxes and street light of size 1x 16 Sq. mm all respect as per E/I. |
| 26 | Supply and fixing of XLPE insulated Aluminium unarmoured cable for working voltage for enerizing the distribution boxes and street light of size 1x 35 Sq. mm all respect as per E/I.(AOR) |
| 27 | Location and pin pointing of 11 KV HT cable fault exposling the same in the underground 11KV HT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR) |
| 28 | Dismantling of 30 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. Complete in all respect . As per direction of E/I. |
| 29 | Fixing of 30 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. on existing foundation. Complete in all respect . As per direction of E/I. |
| 30 | S/F of 100x110mm Shackle insulator/ 100x80 mm pin insulator including G.I. bolts/spindle nuts etc. Complete in all respects PS No. 621 |
| 31 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.(PS no 716/ P-138) |
| 32 | S/E of \\"D\\" Clamp of 50x6 mm. M.S. flat iron on steel tubular poles/steel rail poles with bolts and nuts etc. complete in all respects. As per direction of E/I. P.S. No. 623. |
| 33 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required (AOR) |
| 34 | a) Bituminous Portion (AOR) (2265.0+18% gst) |
| 35 | b) Water Bound Macadam (AOR) (1400.0+18% gst) |
| 36 | Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) (AOR) |
| 37 | Hiring of welding set charges running time @ 6 hrs .10.01.07 N.S.I Jal |
| 38 | Hiring of Gas cutter set with oxygen and LPG running time 6 hrs. 10.01.06 N.S.I Jal |
| 39 | Location and pin pointing of LT cable fault exposling the same in the underground LT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable, by making experts technical staff. Complete in all respects as per direction of Engineer in charge (AOR) |
| 40 | S/F of 11 KV TPMO Relco/Rama/Azad make 9 Nos. insulator of Jai shree/BHEL/ Rama/ Rastriya make complete in all respects as per direction of E/I.(UPERC cost data book 2019/P-48) |
| 41 | S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I..(AoR) |
| 42 | Repairing of 11KV fuse wire/Jumper i/c supply and fixing of required size conductor, fuse wire of 11KV Line/DP structure of Transformer by takinng shutdown from UPPCL Department with all safety instruments like-safety belt, Gloves, shoes and other necessary items complete including all taxes. |
| 43 | FRP fenching( 6 feet height including civil work) as per direction of E/I..(RESPO page no. 53) annexure-29 Please Enable Macros to View BoQ information |