| 1 | Labour only for attending day to day external/treated water supply complaints of all nature including grey water pipe leakage i.e leakage in water supply pipe lines , fitting/fixture, over flow of overhead tank, no water supply in supply tank/direct kitchen tap and grey water supply in graden area and AEPTA landscaping area of Golf Course. Taking out water from trenches during repair including note down the complaints in complaint register complete all as specified and as directed. (Note:- Any material required for attending complaints shall be measured and paid separately under respective item herein after) |
| 2 | Labour only for attending of Electric supply compliants of day to day maintenace of existing LT Panels including connecting electrical accessories / spares of water supply installation, borewell and electrical fitting & light, short circuits in Pump house complete all as specified and as directed.(Note:- Any material required for attending complaints shall be measured & paid separately under respectvie item hereinafter) |
| 3 | Notes for Item No 1.01 & 1.02 :-(i) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician/plumber as applicable assisted with adequate No of helpers complete all as specified and as directed.(ii) The complaints shall be attended and defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complained (iii) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made.(iv) While attending the complaint of water supply /Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' . However no extra payments shall be made for dewatering.(v) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fitting and fixtures will be measured and paid separetely under respective item of Sch A.(vi) All T & P as well as dewatering motor single phase of 3HP with including 100 mtr cable, required for attending the complaints shall be provided by the contracor. (vii) The pipe fitter shall always be in possession of die set complete with cutters , boring Tups , Pipe wrench, Chain wrench,Caulking tools, set of spanners and ladders,wehicle/Ricksha etc Complete,all as required at site. |
| 4 | (viii) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc complete all as required at site and directed by Engr-in-charge.(ix) All material reqd at site for day to day maintenance shall be issued by Deptt under respective items here in after. |
| 5 | Supply only in replacement GI Socket mediumd grade ISI Marked of following sizes ;- |
| 6 | 15 mm bore |
| 7 | 20 mm bore |
| 8 | 25 mm bore |
| 9 | 40 mm bore |
| 10 | 50 mm bore |
| 11 | Supply only in replacement GI Elbow Med grade ISI Marked of following sizes : - |
| 12 | 15 mm bore |
| 13 | 20 mm bore |
| 14 | 25 mm bore |
| 15 | 40 mm bore |
| 16 | 50mm bore |
| 17 | Supply only in replacement GI Union Med Grade ,ISI marked of following Sizes:- |
| 18 | 15 mm bore |
| 19 | 20 mm bore |
| 20 | 25 mm bore |
| 21 | 40 mm bore |
| 22 | 50 mm bore |
| 23 | Supply only in replacement GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of following sizes:- |
| 24 | 15 mm bore |
| 25 | 20 mm bore |
| 26 | 25 mm bore |
| 27 | 40mm bore |
| 28 | 50mm bore |
| 29 | S & F in replacement PVC 'L' type Holder suitable for Aluminium rod,Float Ball etc all as required at site and complete all as specified and as directed of following Sizes:- |
| 30 | 15 mm bore |
| 31 | 20 mm bore |
| 32 | Supply only in replacement GI Reducing socket medium grade ISI marked of the following sizes :- |
| 33 | 25 mmx15mm bore |
| 34 | 20mmx15mm bore |
| 35 | 25 mm x 20 mm bore |
| 36 | 40 mmx 20mm bore |
| 37 | 40 mmx 25mm bore |
| 38 | 50 mmx 20mm bore |
| 39 | Supply only in replacement GI Reducing Elbow medium grade ISI marked of the following sizes :- |
| 40 | 20mmx15mm bore |
| 41 | 25mmx15 mm bore |
| 42 | Supply only in replacement GI Tee Med grade ISI Marked of following sizes : - |
| 43 | 15mm x15mm x15mm |
| 44 | 20 mm x 20 mm x 15 mm |
| 45 | 20 mm x 20 mm x 20 mm |
| 46 | 25 mm x 25 mm x 25 mm |
| 47 | 25 mm x 25 mm x 15 mm |
| 48 | 25 mm x 25 mm x 20 mm |
| 49 | 40 mm x 40 mm x 20 mm |
| 50 | Supply only in replacement GI solid plug heavy duty ISI marked of following sizes |
| 51 | 15mm bore |
| 52 | 20 mm bore |
| 53 | 25 mm bore |
| 54 | S & F Lead pig bar |
| 55 | S & F spun yarn |
| 56 | S & F gland packing of any size |
| 57 | S & F 3 mm thick rubber Gaskets suitable for any size of flanges upto 200 mm dia |
| 58 | Supply only in replacement PTMT float valve with epoxy coated aluminium rod and high density plastic ball of following sizes complete all as specified and as directed |
| 59 | 15mm bore |
| 60 | 20 mm bore |
| 61 | 25 mm bore |
| 62 | S & F in replacement Tank Nipple suitable for HDPE water tank 20 mm dia |
| 63 | S&F in replacement of old gun metal gate valves with iron wheel head screwed both ends for iron pipe , ISI marked , as per IS : 778 of following sizes complete all as specified and as directed |
| 64 | 15mm bore |
| 65 | 20 mm bore |
| 66 | 25 mm bore |
| 67 | 40 mm bore |
| 68 | 50 mm bore |
| 69 | Testing of drinking water collected from local source (bore wells /shallow wells in the area of AGE(U) W/S No.II and submission of detailed test report to the office of Engineer-in-Charge. (i) Carrying out minimum essential testing of water as per IS 10500-2012 mandatory for chemical colour, odour, taste, turbidity, pH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for drinking purposes. (ii) Collection of water from[ different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification Note 1:- Rate Quoted shall also deemed to be included for the followings:- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells) Note 2:- Test reports so collected will be submitted to the Engr-in-Charge every month and failing to which will attaract a penaly of ₹5000/- per report and will be recovered from his |
| 70 | Excvation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required complete all as specified and as directed. |
| 71 | Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 72 | Removing excavated material from site to a distance not exc 50 m away and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed. |
| 73 | Surface dressing of uneven surfaces of the natural ground, rough excavated surfaces and filled area where ordered shall be trimed to an even surface horizontal or slopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site. depth of cutting not exceeding 15 cm complete all as specified and as directed. |
| 74 | S & F in replacement 15 mm bore Bib tap in replacement of old standard of PTMT any colour high pressure screwed for male/ female threaded, for UPVC pipe of size 15mm bore complete all as specified and as directed |
| 75 | Labour work required for taking out suction pipe 80 mm to 200 mm bore from sump of any capacity, dismantling of foot valve screwed / flanged type, and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket/ lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as specified and as directed. |
| 76 | Supply & Fixing in replacement of old rotational moulded Poly-ethylene water storage tanks (cylindrical vertical with closed top) of cap 500 Ltrs hoisted and fixed in position at building top. |
| 77 | M & L For Manual Boring under Road for insertion of Pipeline upto 200 mm dia complete all as specified and directed |
| 78 | Supply and fixing in replacement GI pipe medium grade ISI marked including all fittings as in walls,ceilling ,roof and trenches complete all as specified and as directed of following sizes :- |
| 79 | 15 mm dia |
| 80 | 20 mm dia |
| 81 | 25 mm dia |
| 82 | 40 mm dia |
| 83 | 50 mm dia |
| 84 | 80 mm dia |
| 85 | S & F in replacement of old worn out/broken cast iron/ DI fitting for flanged /spigot and socketed pipes such as bends , reducer, tee pieces , tail pieces , collar, cross , caps & plug upto 150mm bore |
| 86 | Supplying ,laying ,jointing ,testing and commissioning in replacement of DI pipe class K-7 with in side cement mortar lining with spigot and socketed end laid in trenches including rubber gasket joint complete all as specified and as directed at site for the following sizes:- |
| 87 | 80 mm bore |
| 88 | 100 mm bore |
| 89 | 150 mm bore |
| 90 | 200 mm bore |
| 91 | 250 mm bore |
| 92 | S & F in replacement PPR Pipe PN-16, SDR 7.4 of following size |
| 93 | 20 mm bore |
| 94 | 25 mm bore |
| 95 | 90 mm bore |
| 96 | 110 mm bore |
| 97 | Supply and fixing in replacementy of old for mild steel work for manhole cover, stair case steps made of MS angle/ flats/channels etc including cutting out top and bottom to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers,steps etc complete all as specified and as directed. |
| 98 | Supply, fixing, jointing & testing Cast Iron Sluice Valve of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0 PD Short body, confirming to IS 14846-2000, having stainless steel spindle with cast iron operation wheel at top including taking out UNSV Sluice Valve complete all as specified and as directed. (Note:- Flanged joints complete with jointing material including replacement of SS Hexagonal nuts, bolts and washers of suitable size including replacement of flange gasket of suitable thickness shall deemed to be included in the units rate of this item) |
| 99 | 80 mm bore |
| 100 | 100 mm bore |
| 101 | 150 mm bore |
| 102 | Supply, fixing, jointing & testing Cast Iron Non Return Valve without by pass arrangement, swing type confirming to IS 5312, flanged ends pressure reating PN1.0 complete including taking out unsv NRV complete all as specified and as directed. (Note:- Flanged joints complete with jointing material including replacement of SS Hexagonal nuts, bolts and washers of suitable size including replacement of flange gasket of suitable thickness shall deemed to be included in the units rate of this item) |
| 103 | 100 mm bore |
| 104 | 150 mm bore |
| 105 | Supply, fixing, jointing & testing Cast Iron Foot Valve flanged ends, swing type operation with rubber sheet confirming to IS 4038 complete including taking out unsv Foot Valve complete all as specified and as directed. (Note:- Flanged joints complete with jointing material including replacement of SS Hexagonal nuts, bolts and washers of suitable size including replacement of flange gasket of suitable thickness shall deemed to be included in the units rate of this item) |
| 106 | 100 mm bore |
| 107 | 150 mm bore |
| 108 | Supply, installation & testing of flanged ends Water Meter ISI marked woltman type, class 'B' of following sized and making good connection with flanged ends,with rubber sheet gasket and nuts & bolts fixing in horizontal/inclind/verticle position, including taking out UNSV water meter complete all as specified and as directed. type operation with rubber sheet confirming to IS 4038 complete including taking out unsv Foot Valve complete all as specified and as directed. Note:- Flanged joints complete with jointing material including replacement of SS Hexagonal nuts, bolts and washers of suitable size including replacement of flange gasket of suitable thickness shall deemed to be included in the units rate of this item |
| 109 | 80 mm bore |
| 110 | 100 mm bore |
| 111 | 150 mm bore |
| 112 | Material & Labour for painting on steel and iron surfaces with one coat of synthetic enamel paint as per existing colour scheme or pattern complete all as specified and directed |
| 113 | Multipurposes grease lubricant for Motors and Pumps |
| 114 | Supply & Fixing in Replacement of XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade of following sizes complete all as specified and directedNote : Earth work excavation will be measured and paid seperately under relevant items) |
| 115 | Crossectional area 16 Sqmm x 4 core |
| 116 | Crossectional area 25 Sqmm x 3.5 core |
| 117 | Crossectional area 35 Sqmm x 3.5 core |
| 118 | Crossectional area 50 Sqmm x 3.5 core |
| 119 | Crossectional area 120 Sqmm x 3.5 core |
| 120 | Labour only for laying existing burnt bricks sub class 'B' old size laid in trenches with equal to length of bricks across the cable for cable protection complete all as specified and as directed |
| 121 | Supply and spread clean dry river sand to required width at bottom and top for cable cushioning all as specified and as directed |
| 122 | Material and Labour Burnt bricks sub class 'B' old size laid in trenches with equal to length of bricks across the cable for cable protection all as specified and as directed |
| 123 | Repair/maintenance of juction box/pole box as per site including serviceable of bus bar, MCB & changing of cable or make it serviceable condition all as specified and directed. |
| 124 | Supply &Fixing in replacement elecrtonic timer type ST 100 for fixing in panel complete all as specified and as directed |
| 125 | Supply & fixing in replacement of Fully automatic Star-Delta Starter with sheet metal enclosure ML 1.5 |
| 126 | Supply only in replacement of 3 pole power contactor Type MNX 25, 110 Amp ,415/220 volts ,50 hz coil voltage 415 volt |
| 127 | Supply only in replacement of 3 pole power contactor Type MNX 32, 110 Amp, 415/220 volts ,50 hz coil voltage 415 volt |
| 128 | Supply only in replacement of thermal over load relay type MN relay range 28-42 Amps |
| 129 | Supply only in replacement of thermal over load relay type MN relay range 20-32 Amps |
| 130 | Supply only in replacement of thermal over load relay type MN relay range 13-21 Amps |
| 131 | Supply and fixing in replacement LED batten arrow for multi application suitable for 18 watts with & including necessary cable connection to make it functional complete all as specified and as directed |
| 132 | Earthing complete with galvanised steel earth plate electrode 600 x 600 6 mm thick burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level connected to the Galvanised iron strip 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanised iron and 32 x 6 mm GI strip procted by provision of GI light grade pipe 40 mm bore including provision of concrete pit in PCC 1: 2: 4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 kg/sqm and 6 mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashe and medium GI protection pipe 15 mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I complete all as specified and as directed. Note:- 1. Main Earthing strip from earth plate electrode to test point upto length of 7.t meters shall deemed to be included in the unit rate quoted against this items. 2. On testing after completion of the earthing work if the desired resistenance is not obtained, the contractor shall redo the the complete earth work without any extra cost to the department. |
| 133 | Material and labour in replacement for point wiring complete with 1.5 sqmm (nominal crossectional area) FRLS PVC insulated unsheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbows, reducers except conduit junction box (Junction box will be of MS) including FRLS PVC insulated unsheathed 1.5 sqmm copper earth wire, connecting to common earth dolly and including metal flush box of suitable size for fixing switches/sockets/fan regulators etc complete all as directed for the following:- |
| 134 | One light point/fan point/exhaust fan point/circulator fan point/bell/buzzer controlled by one 1 way switch/bell push etc. |
| 135 | One socket outlet point 5 Amps on the same board |
| 136 | One socket outlet point 5 Amps on the independent board |
| 137 | S&F 3 pin socket outlet 15 Amp, independent with 4 sqmm copper FRLS wire. |
| 138 | Supply & fixing in replacement of switch piano, flush type single pole 1 way, 5/6 Apms complete all as specified and directed. |
| 139 | Supply and fixing in replacement of swithc Piano flush type single pole 1 way 15 Amps complete all as specified and directed. |
| 140 | Supply and fixing in replacment of socket outlet 6 Amp 2 in 1,3 pin complete all as specified and directed. |
| 141 | Supply and fixing in replacment of socket outlet 16 Amp 2 in 1, complete all as specified and directed. |
| 142 | Supply and fixing in replacement of Fan regulator step type complete all as specified and directed. |
| 143 | Supply and fixing in replacement of Ceiling rose, surface bakelite, 3 terminal, 240 volts, 5 Apms complete all as specified and directed. |
| 144 | S & F in replacement for fixing MCCB's following sizes in existing/new location complete all as completed. |
| 145 | MCCB 63 Amps 3 Pole 16 KA |
| 146 | MCCB 100 Amps 3 Pole 16 KA |
| 147 | MCCB 125 Amps 3 Pole 16 KA |
| 148 | MCCB 160 Amps 4 Pole 36 KA |
| 149 | MCCB 200 Amps 4 Pole 36 KA |
| 150 | MCCB 250 Amps 4 Pole 36 KA Please Enable Macros to View BoQ information |
| 151 | MCCB 250 Amps 4 Pole 36 KA Please Enable Macros to View BoQ information |