| 1 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. P.s No 501 (Make- Havells/KEI/Polycab) |
| 2 | 10 Sq.mm. x 2 Core |
| 3 | 16 Sq.mm. x 4 Core |
| 4 | 70 Sq.mm. 3.5 Core |
| 5 | S/F of Plain of pin type copper tin plated cable socket(lug) to the cable leads, insulating with tape and making connection etc. Complete in all respects as per direction for E/I (PS No. 504) |
| 6 | 10 Sq.mm. |
| 7 | 16 Sq.mm. |
| 8 | 70 Sq.mm. |
| 9 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.DSR 14.16 |
| 10 | 63 mm dia (OD-63 mm & ID-51 mm nominal) DSR.14.16.1 |
| 11 | 90 mm dia (OD-90 mm & ID-76 mm nominal)DSR.14.16.2 |
| 12 | SITC of Outdoor Architectural LED Circular projector flood light with system wattage not more than 50W,system efficacy>45LPW(+5%),CCT RBGW(W=3000k) with 4 in 1 LED chip for uniform illumination ensuring every LED in Luminare reproducing same color at all time ,system lumen output should not less than 2160lm(10%) with all RBGW channels ON.Fixture should have Integral Driver & 4 channel Decoder,Fixture should be compatiable for DMX512 and able to reproduce 16 Millon colors with 256 step dimming.(Make- NERI/LT/Colour Kinetic) |
| 13 | Supply, Installation, Testing and Commissioning of LED RGBW Floodlight Luminaire for Facade lighting with die cast aluminium housing, with powder coating of wattage 55W with suitable hood for asymmetric distribution. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fixture shall be 30 deg. The luminaire shall have high optical efficiency, anti aging and anti UV PMMA/PC lenses. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 120 to 270 V AC, 50 Hz, power factor > 0.9. High power LED's shall be SMD type and fixture shall have system efficacy at System level (Not Chip Level) >=40 LPW, Life of fixture (Including Driver): 50K Hrs. @ L70 Lumen maintenance at 35 °C Ambient Temperature. CRI ≥ 70 at 3000K, PF >0.90 & THD<20%, minimum Internal Surge Protection 4KV, 20 kV external surge protector, must be having IP66 & IK 07 Impact rating & Approbation-CE along with IEC Classification Class I, RoHS. Cables Connectors in fixture to be of IP67 for Male/Female connectors for DMX through wiring. Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015IES, LM 79, & TTC certificates should be provided from NABL accredited lab. Certification: CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers 5 Years Warranty. AOR (Make- NERI/LT/Colour Kinetic) |
| 14 | Supply, Installation, Testing and Commissioning of LED RGBW Floodlight Luminaire for Facade lighting with die cast aluminium housing, with powder coating of wattage 70W-75W. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fixture shall be 30 deg. The luminaire shall have high optical efficiency, anti aging and anti UV PMMA/PC lenses. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 120 to 270 V AC, 50 Hz, power factor > 0.9. High power LED's shall be SMD type and fixture shall have system efficacy at System level (Not Chip Level) >=40 LPW, Life of fixture (Including Driver): 50K Hrs. @ L70 Lumen maintenance at 35 °C Ambient.............IP67 for Male/Female connectors for DMX through wiring. Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, & TTC certificates should be provided from NABL accredited lab. Certification: CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers 5 Years Warranty. AOR (Make- NERI/LT/Colour Kinetic) |
| 15 | Supply, Installation, Testing and Commissioning of LED RGBW Linear Grazer Luminaire for Facade lighting with extruded aluminium housing, with powder coating of wattage 40W. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fixture shall be 15x45 deg. The luminaire shall have high optical efficiency, anti aging and anti UV PMMA/PC lenses & toughened Glass cover . Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 120 to 270 V AC, 50 Hz, power factor > 0.9. High power LED's shall be SMD type and fixture shall have system efficacy at System level (Not Chip Level) >=40 LPW, Life of fixture (Including Driver): 50K Hrs. @ L70 Lumen maintenance at 35 °C Ambient Temperature. CRI ≥ 70 at 3000K, PF >0.95 & THD<10%, minimum Internal Surge Protection 3KV, 10 kV external surge protector, must be having IP66 & IK 08 Impact rating & Approbation-CE along with IEC Classification Class I, RoHS. Cables Connectors in fixture to be of IP67 for Male/Female connectors for DMX through wiring. Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, & TTC certificates should be provided from NABL accredited lab. Certification: CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers AOR(Make- NERI/LT/Colour Kinetic) |
| 16 | SITC of 6 Output DIN Rail Mount DMX Splitter. - Fully isolated Outputs to Split/Boost DMX Input. - Compact Din Mount Size- Terminal Block Connectors for easy solderless termination.- Incl. External Power supply with built-in protection for Short circuit / Overload / Over voltage / Over temperature. UL508 & EN50082-2 certified 5 Years Warranty.AOR (Make- NERI/LT/Colour Kinetic) |
| 17 | SITC of 2 Output compact DIN Rail Mount DMX Splitter with 5 Years Warranty.(Make- NERI/LT/Colour Kinetic) |
| 18 | SITC of 'Programming of the entire job with desired themes as per the engineer in charge 5 Years Warranty. AOR |
| 19 | Supply and Laying of Control Copper cable for Mertering as per direction of E/M. 2 x 2.5 sqmm . AOR |
| 20 | Supply, Installation, testing & Commissioning of flexible copper power cable 3 x 2.5 sqmm . AOR |
| 21 | Supply installation testing and Commissioning of DMX Wire 2Core 0.75 mm Shielded cable Network wiring consists of a shielded twisted pair, with a characteristic impedance of 120 ohms, with a termination resist or at the end of the cable farthest from the controller to absorb signal reflections 5 Years Warranty. AOR |
| 22 | Supply and fixing of 15 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807 |
| 23 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required..DSR.2018 1.20.2 (25mm) |
| 24 | Stand Alone DMX controller with Zone management and 16-bit channel management. RDM Enabled. Extensive external triggering operations via Dry Contact ports, TCP/UDP along with Calendar Triggers. Ethernet Integration. IOS/Androd APP based wireless control. 1024 DMX channel control with an option to get a paid upgrade to 2048 channels. DC5-5.5V Input via external adaptor. Up to 32BG memory. Using light show authoring software to select from standard 10 effects, adjust effect settings such as color, speed, and brightness 5 Years Warranty. AOR |
| 25 | Supply and Fixing 150X150 mm Bollard Lights (12W) made out of extruded 3mm aluminium profile with cast aluminium fixed with GI fastners on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and required T&P complete in all respect. as per approved design and drawing as approved by architect and Engineer-in-charge .AOR |
| 26 | Supply Instalation testing & commissioning of Homogeneous Dot free LED Flexible Linear Light Wattage 12W with high quality circuit design for stable and reliable performance, surface material should be made of Silicon with aluminium extrusion linear profile and other connecting accessories, Surface mounted flexible linear light suitable for facade edge lighting, Symmetric distribution. luminaire should have diffuse silicone based cover for soft illumination. Rated input supply of DC 24V constant voltage with external LED Driver, External ballast as accessory must be provided separately, Output color should be RGBW. The luminaire should have versatile optics : 120°, Mean rated service life L70(tq 25 °C) = 50,000 h. Luminaire body of aluminium extrusion ................ LED system with control gear unit is suitable for operation on direct voltage supply grids. The luminaire should be provided with Electrical safety class I. Power Efficiency : >85%, Operating Temperature : - 10°C to +55°C, Operating Humidity : 10%-90%, Housing to have customised base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements 5 Years Warranty. AOR |
| 27 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). UPPWD SOR -2018 Item no. (702) Electrical |
| 28 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.(P.S. No 725A) |
| 29 | Supply and fixing of horizontal air termination (roof conductor) of 25mm x 3mm G.I. strip, G.I. clamps on surface complete in all respects as approved by Engineerin-charge. UPPWD -2018 Item no. (710) Electrical |
| 30 | Supply of Steel Tubular Pole 11 M long designated 410-SP-56 . complete in all respects as per direction of E/I. .(UPERC P-30) |
| 31 | Supply and erection of overhead line with ACSR Conductor (Dog & Raccoon) poles / service bracket including binding etc. complete in all respects. P.S. No. 627 |
| 32 | Painting of the electric pole with 2 Coats of aluminium paint over red oxide primer complete in all respects. P.S. No. 634 |
| 33 | Supplying of channel iron 75mmx40mmx6mm(7.14 Kg Per mtr) pole top bracket/cross arm for single 11 kV overhead line conductor complete with 50mmx6mm flat iron clamp, bolts, nuts and washer including drilling holes for insulator pins bolts and nuts etc, and painting with primer and finish paint as required (DSR-2018 item no. 13.2 pg.44) |
| 34 | S/E of straight MS Channel 50x100 mm. (9.2 Kg/M) 2.60 M long as per design with required clamps made of M.S. flat of size 50x6 mm. with nut & bolts etc. as per direction of E/I. .((UPERC P-30) |
| 35 | Supplying and erection of 11kV pin insulator complete with large steel head G.I. Pin, nuts & washer etc. as required (DSR-2018 item no. 13.10 ) |
| 36 | Supplying and erection of 11kV Disc insulator for 11kV overhead line with galvanised inculator fitting, ball and socket type and complete with galvanised strain clamp, bolts, nuts & washer etc. as required (DSR-2018 item no. 13.11 ) |
| 37 | S/F of 11 KV TPMO Relco/Rama/Azad make 9 Nos. insulator of Jai shree/BHEL/ Rama/ Rastriya make complete in all respects as per direction of E/I.(UPERC ) |
| 38 | S/E Testing & Commissioning of 63 KVA copper wound Oil field type outdoor Transformer as per ISS. Complete in all respects Make : as per approved in UPPCL as per direction of E/I..(UPERC ) |
| 39 | S/F of 6\\" dia G.I. pipe B class for cable duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-41) |
| 40 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required (AOR) |
| 41 | (Bituminous Portion) |
| 42 | Water Bound Macadam |
| 43 | Earth work in Excavation in by mechanical means (Hydraulic excavator) manual means over areas excaading 30 mtr in depth,1.50 mtr width as well as 10sqm on plan)including out and desposal of excavated earth ,load upto 50m and lift upto 1.5 m as directed by the Engineer incharge The Contractor has defect diffrent utillities like Sewer line,water supply line,electric cable,telephone cable,gas pipe line,etc.using utility defecting machine before start of excavation and shall start excavation only after getting permission of Engineer in charges.(AOR). P-16 |
| 44 | Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) (AOR) |
| 45 | Filling available excavated earth( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. (AOR). P-16 |
| 46 | S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I.(AOR) |
| 47 | Operation & Maintenance and defect liablility charges from the date of testing and commissioning of the project @0% |
| 48 | Operation and Non Comprehensive Maintenance of above all lights, controller, splitters and other all equipments installed by workingagencies including replacement of defective lights and other parts which are under defect Liabiity period with theft liabelity also complete for 2nd year.(Monthly Payment of 27163.16-/ )AOR |
| 49 | Operation and Non Comprehensive Maintenance of above all lights, controller, splitters and other all equipments installed by workingagencies including replacement of defective lights and other parts which are under defect Liabiity period with theft liabelity also complete for 3rd year.(Monthly Payment of 40744.91-/ )AOR Please Enable Macros to View BoQ information |